{"id":6656968228941,"title":"Tempco Duraband ® (Micaband) Band Heaters","handle":"tempco-duraband®-micaband-heater","description":"\u003cp data-mce-fragment=\"1\"\u003eDuraband is a mica insulated heater incorporating a Low Thermal Expansion Alloy outer sheath that is used as a uniquely designed Built-In Strap.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIt is a proven heater design for good life efficiency and dependability. It assures maintaining the lowest winding temperatures possible, keeping a low-mass heating element assembly for fast heat-up and quick thermal response to controls. It incorporates the Low Thermal Expansion Built-In Strap, a unique design feature originally developed and patented by Tempco.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Temperature:\u003c\/strong\u003e Standard Sheath: 900°F (482°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNominal Watt Density: \u003c\/strong\u003e20-45 W\/in\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e (3-7 W\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e )\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Watt Density:\u003c\/strong\u003e Dependent on heater size and operating temperature.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-27 for calculating maximum watt density, and additional specifications.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul class=\"noBullets\"\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eDual Voltage or 3-Phase:\u003c\/strong\u003e Available depending on heater design\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eMaximum Amperage: \u003c\/strong\u003e\u003c\/em\u003e\u003cem\u003eLead Wire Termination: 12.5A, \u003c\/em\u003e\u003cem\u003eScrew Terminations: 8-32UNF—20A and 10-32UNF—25A\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e +10%, –5%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e +5%, –10%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-24 and 1-25 for additional temperature, and thermal conduction information.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003ePhysical Size Construction Limitations\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e ±1\/16\" (1.59 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eNominal Gap:\u003c\/strong\u003e 3\/8\" (9.5 mm)—If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-26 for a listing of Standard Specifications and Tolerances.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eBuilt-In Brackets\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater Width\u003c\/th\u003e\n\u003cth\u003eNumber of Brackets\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\" to 3\" (38-76 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1\/8\" to 5\" (79-127 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5-1\/8\" to 6-7\/8\" (130-145 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\" to 10\" (178-254 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-1\/8\" to 15\" (257-381 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eMinimum ID and Width for Construction\/Clamping Styles\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eMin. ID\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eMin. Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStyle\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e76.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-Jul\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e22.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNSL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNEL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTWL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e134.7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e254\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eRecommended Segments by Inner Diameter\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eNumber of Segments\u003c\/th\u003e\n\u003cth\u003eID Range\u003c\/th\u003e\n\u003cth\u003eID Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15-1\/2\" \u0026amp; Smaller\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm \u0026amp; Smaller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 28\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 711.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 45\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 1143mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 1422.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 86\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 2184.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25\" to 96\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 2438.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eStock Heaters:\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eFor ordering information, see reference page 1-48. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo order by part number, see reference pages 1-52 through 1-59.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eCustom Engineered\/Manufactured Heaters:\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eFor ordering information, see reference page 1-48. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eNote: Refer to individual descriptions for further ordering information.  Actual heater minimums will be a combination of termination and construction\/strap styles.\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Lead Terminations, see reference pages 1-32 through 1-45\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Construction Styles, see reference pages 1-28, 1-46, and 1-47\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Clamping Variations, see reference pages 1-29 through 1-31\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eOne Piece Band Construction\u003c\/h4\u003e\n\u003ctable style=\"width: 99.4841%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB544.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB544.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe one-piece construction is available on any screw or lead termination and clamping variation. It can be used where band heaters can be slipped over the end of the cylinder.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTwo Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.3863%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.3863%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Duraband two-piece construction provides a built-in hinge, making handling and installation easier. It is used on large cylinders or where the heater cannot be slipped over the end of the cylinder.  Two-piece band heaters are rated at watts and volts per each half when ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eOne Piece Expandable Band Construction \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.8865%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.8865%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe one-piece expandable construction is available on any screw or lead and clamping variation and can be used where a one-piece band heater would have to be expanded to fit over the barrel during installation, rather than slipped over the end of the barrel.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n                                                                                                                                \n\u003ch4\u003eType NS: Partial Coverage Band with Built-In Brackets (2 Piece)                               \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg?Small\"\u003e              \u003cimg alt=\"Angle of Coverage Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\" width=\"163\" height=\"163\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePartial coverage band heaters are normally required when holes and cutouts will not allow the heater to sufficiently clear the machine obstructions.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of construction is the Two-Piece Band Heater with Built-In Brackets as illustrated. The heater is screwed down to the cylinder at the ends and the built-in Low Thermal Expansion Strap pulls the heater tightly against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard center of hole to edge of heater dimension is 1\/4\". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType PS: Partial Coverage Band with Separate Strap (2 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg?Small\"\u003e                \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" alt=\"Angle of Coverage Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe alternate method of partial coverage construction is the One-Piece Band Heater with a separate Two-Piece Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe two-piece strap itself is screwed down at the padded ends, allowing the heater to float between the pads as illustrated. When the strap is tightened, it will pull the heater against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard center of hole to edge of heater dimension is 1\/4\". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n                               \n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType NB: Partial Coverage Band with Built-In Strap (1 Piece)\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 31.6479%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg?Small\"\u003e                 \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_TypeNB.jpg?Medium\" alt=\"Type NB Angle of Coverage Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_TypeNB.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 31.6479%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003eAnother alternate method of partial coverage construction.  The one piece with clamp screws on both sides allows it to be secured to anchor points on either side of a barrel without drilling holes into the barrel.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType RNB: Reverse Band Construction with Bracket Clamping (1 Piece)\u003c\/h4\u003e\n\u003ctable style=\"width: 99.7039%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 13.9662%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 41.0338%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters 5-1\/2\" diameter and larger.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 5-1\/2\" (139.7 mm) to 10\" (254.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003eFor ID's greater than 10\" see \u003cstrong\u003eType RNS\u003c\/strong\u003e.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType RNS: Reverse Band Construction with Bracket Clamping (2 Piece)\u003c\/h4\u003e\n\u003ctable style=\"width: 99.9473%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 32.373%;\"\u003e \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 55.627%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters 10\" diameter and larger.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 10\" (254.0 mm) to 20\" (508.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFor ID's greater than 20\", Contact IHS for Assistance.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ch4 data-mce-fragment=\"1\"\u003eType RTWL: Reverse Band Construction with Wedge Lock (1 Piece)   \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9122%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10.4112%;\"\u003e \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 42.5888%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters less than 5\" outside diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 5-1\/2\" (139.7 mm) to 20\" (508 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSquare or Rectangular Shape \u003cspan\u003e \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 100.035%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.5072%;\"\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg\" width=\"156\" height=\"156\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"182\" width=\"182\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110.jpg\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"178\" width=\"178\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110A.jpg\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110A.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"174\" width=\"174\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110B.jpg\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110B.jpg\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.4928%;\"\u003e\n\u003cp\u003e\u003cem\u003eSquare or Rectangular band heaters are normally used for heating dies on plastic extruders, or the barrels of twin screw extruders. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be made in either one- or two-piece construction but two-piece construction with Style 1 Clamping (see below) is recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWidth Range: \u003c\/strong\u003e1\" to 3-1\/2\" (25.4 - 88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 1 for 2-Piece Heaters (Recommended):\u003c\/strong\u003e bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 25 w\/in\u003csup\u003e2\u003c\/sup\u003e \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 2 for 2-Piece Heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum \"B\" dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 20 w\/in\u003csup\u003e2\u003c\/sup\u003e \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 3 for 1-Piece Heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum \"A\" dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 25 w\/in\u003csup\u003e2\u003c\/sup\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHexagon Shape \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3577%;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB0101.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB0101.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3577%;\"\u003e\n\u003cp\u003e\u003cem\u003eHexagon shaped band heaters are used on the hex shaped portion of the nozzle on injection molding machines.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThese types of heaters are strictly made to customer specifications with bent-up flange clamping only.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 1\u003c\/strong\u003e \u003cstrong\u003efor 2-piece heaters:\u003c\/strong\u003e bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible. Maximum Recommended Watt Density: 25 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 2\u003c\/strong\u003e \u003cstrong\u003efor 2-piece heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum “B” dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eMaximum Recommended Watt Density: 20 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 3\u003c\/strong\u003e\u003cstrong\u003e for 1-piece heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum “A” dimension of 3.75\" (95.3 mm). Maximum Recommended Watt Density: 25 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eClamping Options:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NB: Standard Built-In Clamping (Low Thermal Expansion), One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type NB Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system. The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NS: Standard Built-In Clamping (Low Thermal Expansion), Two Piece Band\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e                 \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e                  \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" alt=\"Type NB Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NE: Standard Built-In Strap Clamping (Low Thermal Expansion), One Piece Band                                                                                                                               \u003c\/h4\u003e\n\u003ctable style=\"width: 99.2349%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\n\u003cp\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e                   \u003cimg height=\"163\" width=\"163\" alt=\"Type NE Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType TWL: Wedge Lock, One Piece Band   \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e                                                                      \u003c\/h4\u003e\n\u003ctable style=\"width: 99.8458%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type TWL drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB9.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB9.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38%;\"\u003e\n\u003cp\u003e\u003cem\u003eWedge Lock clamping is designed for applications where mounting space is severely limited.  It lends itself mainly to small diameter nozzle heaters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-29 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SB: Separate Straps, One Piece Band  \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e                                                                     \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9507%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type SB Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9507%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SS: Separate Straps, Two Piece Band                                          \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 99.9121%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SE: Separate Straps, One Piece Expandable Band                                                    \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 97.3464%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 97.3464%;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 36%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 36%;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e      \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 36%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 36%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLimitations\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-3\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SL: Spring Loaded with Built-In Bracket, One Piece Band                  \u003c\/h4\u003e\n\u003ctable style=\"width: 99.7538%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31%; text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31%; text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSL: Spring Loaded with Built-In Bracket, Two Piece Band     \u003cspan\u003e \u003c\/span\u003e         \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9208%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eNote: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NEL: Spring Loaded with Built-In Bracket, One Piece Expandable Band               \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0244%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0244%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine. The springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SLQD: Spring Loaded Quick Disconnect, One Piece Band \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.8596%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.8596%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3.5\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSLQD: Spring Loaded Quick Disconnect, Two Piece Band \u003c\/h4\u003e\n\u003ctable style=\"width: 99.7801%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This cla\u003c\/em\u003emping style is available with either lead or screw terminal type terminations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NELQD: Spring Loaded Quick Disconnect, One Piece Expandable Band \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0882%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0882%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3.5\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LT: Latch and Trunnion, One Piece Band   \u003cspan\u003e \u003c\/span\u003e                                                      \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.4456%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.4456%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation.  \u003c\/em\u003e\u003cem\u003eIt is ideal in absorbing thermal expansion due to the spring loading on the screws. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders.  \u003c\/em\u003e\u003cem\u003eThe outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\" (177.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eNote: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LS: Latch and Trunnion, Two Piece Band     \u003c\/h4\u003e\n\u003ctable style=\"width: 99.5661%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003cbr\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eMinimum Inside Diameter: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e7\" (177.8 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eMinimum Width: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e1\u003c\/em\u003e\u003cem\u003e-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LE: Latch and Trunnion, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.\u003c\/em\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLimitations\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\" (177.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n           \n\u003ch4 data-mce-fragment=\"1\"\u003eType FB: Bent-Up Flange (Ears), One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType FS: Bent-Up Flange (Ears), Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType FE: Bent-Up Flange (Ears), One Piece Expandable Band                                         \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy.  The Bent-Up Flange design is best suited for narrow band heaters with small diameters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Screw Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.3576%;\"\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.3576%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.4298%;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg?Small\"\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.4298%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gaps on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.557%;\"\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.557%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals: \u003c\/strong\u003e10-32 standard except 8-32 on heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e      \u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enext to same gap on each half; center of width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\" (50.8 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMb119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMb119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/25A (10-32) or 20A (8-32)\u003c\/p\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, Two Piece Band\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Button Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003e\u003cspan\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gaps on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size: \u003c\/strong\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/em\u003e\u003cem\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/em\u003e\u003cem\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg\" width=\"152\" height=\"152\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg?Small\"\u003e      \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e                        \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size: \u003c\/strong\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Lead Wire Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 198px;\"\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB554.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB554.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 319px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, Two Piece Band\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 199px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_2Pc.jpg?Small\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 318px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width:\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm):\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm):\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.125px;\"\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_1PcX.jpg?Small\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 321.875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eStandard Termination Location\u003c\/strong\u003e\u003cspan\u003e: next to gap; center of width\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/4\" (31.8 mm)\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 480V\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMaximum Amps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e12.5A\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.344px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB574.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB574.jpg?Small\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 317.656px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e3\/4\" (19.1 mmL\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.391px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_2Pc.jpg?Small\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 325.609px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eeach side of each gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\" data-mce-fragment=\"1\" data-mce-style=\"width: 533px;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 220.531px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 36px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px; width: 36px;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_1PcX.jpg?Small\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 491px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px; width: 491px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: 2-1\/2\" (63.5 mm)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts:\u003c\/strong\u003e 480V\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.814%;\"\u003e\n\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg?Small\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 47.186%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e same side of gap; edge of width\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.8032%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1968%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of same gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 198.953px;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 318.047px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eSame side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Wire Braid Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                          Type W1                       Type W1T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e         \u003cimg height=\"120\" width=\"120\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e       \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" alt=\"Type W1T\" width=\"120\" height=\"120\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                             W1T                            Type W1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.625px;\"\u003e\n\u003ctd style=\"height: 20.625px;\"\u003e        \u003cimg height=\"120\" width=\"120\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_2Pc.jpg\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                        Type W1T                        Type W1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg?Small\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.9352%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.0648%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segmet for expandable designs.\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSleeving is used for additional protection.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-37 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.2261%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 55.7739%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segment for expandable designs.  \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSleeving is used for additional protection.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6241%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.3759%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap offset 1\"; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segment for expandable designs.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eSleeving is used for additional protection.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.4687%;\"\u003e\n\u003cimg height=\"152\" width=\"152\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg?Small\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 58.5313%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  The standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.3371%;\"\u003e \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6629%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eeach side of each gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7886%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2114%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1293%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.8707%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7153%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2847%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.5959%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.4041%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: , Right-Angle Wire Braid Leads, 90° to Heater, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.4307%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.5693%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90° to Heater, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8229%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.1771%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90° to Heater, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9297%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 53.0703%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7056%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.2944%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.2224%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 53.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each side; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: The minimum heater width with a coupling is 1-1\/2\". If heater width is smaller than 1-1\/2\", heater gap will be used for coupling location.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7806%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2194%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Armor Cable Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT\u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT\u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D\u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E\u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F\u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT\u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width=\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT\u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D\u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E\u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F\u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg?Small\"\u003e               \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (65.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A \u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT \u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B \u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT \u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C \u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D \u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E \u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F \u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A\u003c\/strong\u003e – Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A \u003c\/strong\u003e– Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg?Small\"\u003e            \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A\u003c\/strong\u003e – Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: Multiple segment designs are recommended on larger diameter (typically larger than 15\") heaters to improve the clamping force and increase the surface contact between the heater and the barrel for efficient heat transfer.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg?Small\"\u003e        \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e      \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: The One-Piece Expandable Band should not be opened and closed more than twice.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 167px;\"\u003e\n\u003ctd style=\"height: 167px;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6562px;\"\u003e\n\u003ctd style=\"height: 21.6562px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Lead Wire Spring Strain Relief Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 96.0152%; text-align: center;\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg?Small\" data-mce-selected=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 96.0152%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1\/8\" long. The flexible standard leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType S1A –\u003c\/strong\u003e Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1AT –\u003c\/strong\u003e Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1B –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1BT –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width. 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1\/8\" long. The flexible standard leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType S1A –\u003c\/strong\u003e Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1AT –\u003c\/strong\u003e Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1B –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1BT –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width. 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, One Piece Expandable Band\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminal Boxes: Standard Terminal Boxes\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A –\u003c\/strong\u003e Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C –\u003c\/strong\u003e w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg?Small\"\u003e         \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A –\u003c\/strong\u003e Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C –\u003c\/strong\u003e w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003eType C2D –\u003c\/strong\u003e w\/wire braid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A\u003c\/strong\u003e – Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B\u003c\/strong\u003e – w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C\u003c\/strong\u003e – w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2D\u003c\/strong\u003e – w\/wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminal Boxes: Low-Profile Terminal Boxes\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\"\u003e             \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location\u003c\/strong\u003e: next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Quick Disconnect Plugs: Standard\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 517px;\"\u003e                                                    Type P1M                        Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 163px;\"\u003e\n\u003ctd style=\"height: 163px; width: 517px;\"\u003e   \u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg?Small\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1M\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1L\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 517px;\"\u003e                                                     Type P1M                      Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 163px;\"\u003e\n\u003ctd style=\"height: 163px; width: 517px;\"\u003e\n\u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg?Small\"\u003e       \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" alt=\"Type P1M\" width=\"140\" height=\"140\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" alt=\"Type P1L\" width=\"140\" height=\"140\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                    Type P1M                       Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003e \u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg?Small\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1M\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1L\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e572°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".  If width is greater than 2\", the minimum diameter is 2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Quick Disconnect Plugs: Low-Profile\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                   Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P2G\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38.6562px;\"\u003e\n\u003ctd style=\"height: 38.6562px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                   Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg?Small\"\u003e               \u003cimg height=\"193\" width=\"193\" alt=\"Type P2G\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e572\u003c\/span\u003e°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType\u003c\/strong\u003e \u003c\/em\u003e\u003cem\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                     Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.4062px;\"\u003e\n\u003ctd style=\"height: 25.4062px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" alt=\"Type P2G\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e572\u003c\/span\u003e°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                               Type P3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg?Small\"\u003e      \u003cimg height=\"193\" width=\"193\" alt=\"Type P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e        \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                        Type P3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" alt=\"Type P3\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                       Type P3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5312px;\"\u003e\n\u003ctd style=\"height: 35.5312px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                    Type P4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" alt=\"Type P4\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.9062px;\"\u003e\n\u003ctd style=\"height: 40.9062px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal,  Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                    Type P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e         \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal,  One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                    Type P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29px;\"\u003e\n\u003ctd style=\"height: 29px;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.6562px;\"\u003e\n\u003ctd style=\"height: 28.6562px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Igloo Ceramic Terminal Covers\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C6, C7, and C8 Igloo Ceramic Terminal Covers\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                Type C6                           Type C7                         Type C8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e       \u003cimg height=\"120\" width=\"120\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg?Small\"\u003e          \u003cimg height=\"117\" width=\"117\" alt=\"Type C7\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB203.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB203.jpg?Medium\"\u003e         \u003cimg height=\"117\" width=\"117\" alt=\"Type C8\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB201.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB201.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eIgloo® Ceramic Terminal Covers consist of two individual ceramic parts. Unlike conventional ceramic caps, Igloo fully insulates any standard #8 or #10 terminal lugs used for electrical hook-ups.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-33 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e\u003ci\u003eMinimum Inside Diameter: \u003c\/i\u003e\u003c\/b\u003e\u003ci\u003e2\" (50.8 mm)\u003c\/i\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: To assemble Igloo covers, terminals should be at least 7\/8\" apart.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"MainContent\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThree types of Igloo™ bases are available:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e – Double Port In-Line P\/N CER-101-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e – Double Port 90° P\/N CER-101-10\u003c\/em\u003e6\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e – Single Port P\/N CER-101-107\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eIgloo™caps are available in the following three screw terminal sizes:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-32\u003c\/strong\u003e – P\/N CER-102-101\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-24\u003c\/strong\u003e – P\/N CER-102-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e8-32\u003c\/strong\u003e – P\/N CER-102-105\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: When ordering, specify the type of Igloo and the screw terminal size.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThermocouple Fittings:\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThermocouple Bayonet Adapter\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg?Small\"\u003e          \u003cimg height=\"193\" width=\"193\" alt=\"Thermocouple Bayonet Adapter\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\"\u003e    \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA standard Bayonet Adapter facilitates the installation of an external thermocouple with a standard bayonet cap. The standard location for the adapter is 90° from the gap. Specify without through hole for heater sensing or with through hole for load sensing. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor heaters less than 1\" wide order separate strap clamping and utilize the gap for the thermocouple.  Refer to Temperature Sensors for a complete selection of thermocouples available from stock.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThermocouple Coupling\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 98.3666%;\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\" alt=\"Thermocouple Coupling\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 98.3666%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Thermocouple Coupling facilitates the installation of an external thermocouple with a threaded fitting to sense the temperature of the band. The standard location for the coupling is 90° from the gap. Specify without through hole for heater sensing or with through hole for load sensing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e \u003c\/h6\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/8-27 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e9\/16\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e11\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/8-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\/8\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eM12–1.75 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Design Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHoles and Cutouts\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.1093%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.8907%;\"\u003e\n\u003cp\u003e\u003cem\u003eHoles and cutouts are normally required in band heaters for clearance for thermocouple probes or holding bolts. An oversize gap can in many cases serve the same purpose, saving the expense of the hole.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUsing the center of the gap as a starting point, specify the location of the center-point of the hole or cutout in terms of degrees and the distance from the edge of the heater. In addition, state the size of the hole or cutout.  For critical hole and cutout locations, a detailed drawing will be required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHinged Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.5307%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.4693%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Hinged Two-Piece Band Heater is connected with a continuous hinge for easy installation and removal. This heater can be opened and closed as often as is necessary. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of clamping is latch and trunnion. It is available with any screw or lead variation. When ordering, specify watts and volts each half.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eRing Heaters\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e             \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB111A.jpg?Medium\" alt=\"Ring Heaters\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB111A.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 43.6562px;\"\u003e\n\u003ctd style=\"height: 43.6562px;\"\u003e\n\u003cp\u003e\u003cem\u003eWhen ordering Ring Heaters, specify inside and outside diameters. If mounting holes are required, specify location and hole size. For critical hole and cutout locations, a detailed drawing will be required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eCone Shape Heaters\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Cone Shapes\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB112.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB112.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eCone Shaped Heaters are normally used for special heating applications when heat is required for hoppers or funnels. They are made strictly to customer specifications. The preferred method of attachment is with built-in bracket clamping. When ordering or for quoting purposes, supply a detailed drawing or sample part. Include the top ID, bottom ID, and the vertical rise or heater width.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSpecial Custom Designs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eNo other heater band has the design and manufacturing flexibility of mica insulated heaters. Tempco's flexible CNC sheet metal fabricating machines, custom developed engineering programs with built-in intelligence, and experienced and talented engineering staff allow us to push the limits on band heater designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAs a custom heating element manufacturer, we recognize that many applications require non-standard and unique designs.  \u003c\/em\u003e\u003cem\u003eWhen you have a special application and you want someone to work who has a \"think outside the box\" mentality, Call us at (844) 862-7880 to discuss additional design options!\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-49 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThree-Phase Option\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eOn very high wattage band heaters it would be advantageous to set up the wiring three-phase to reduce the current load across a single conductor. Three-Phase wiring is available on select clamping\/construction or termination variation (termination location is subject to engineering approval).\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. ID:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eDual Voltage Option\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eBand heaters can be designed using 3-wire series\/parallel circuits for dual voltage applications. Whether the heater is run on the higher or lower voltage, the wattage will be the same. Dual Voltage wiring is available on any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eGround Terminal or Lead\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor those applications requiring a separate ground terminal or lead attached to the heater sheath. A Ground Terminal or Lead is available on any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSingle Phase\/Three Phase Power\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eDuraband Heaters can be designed with multiple circuits to operate single or three-phase.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eBuilt-In Thermocouples\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHeaters can be manufactured with a Built-In Thermocouple to closely control the temperature of the heater. Type J or K thermocouples are available with fiberglass, wire braid or any other required insulation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eAll Stainless Steel Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eAll Stainless Steel Construction  Mica band heaters can be constructed with the external sheath made entirely from stainless steel. This allows the Duraband to reach the maximum temperature of 1200°F (650°C). All Stainless Steel Construction is available on any clamping\/construction or termination variation. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eAdditional Sheath Materials\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem\u003eOther sheath materials, such as rust-resistant steel, Monel®, aluminum, or copper are also available for unique applications.\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eElectrical Plugs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               Type P4 Electrical Plug            Type P5 \u0026amp; P9 Electrical Plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\" alt=\"P4 Electrical Plug\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\" alt=\"P5 Electrical Plug\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eIndustry standard NEMA Twist-Lock® electrical plugs are available. The plugs can be attached to fiberglass leads, armor cable or wire braid. Electrical Plugs can be added to any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTerminal Lugs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003cem\u003eVarious types of crimp terminals can be attached to the heater leads to make wiring into applications quick and easy. High temperature 1200°F (649°C) ring terminals and nylon or PVC insulated terminals are available. Spade, ring, and right-angle or straight quick disconnect type terminals can be attached to the leads.\u003c\/em\u003e\u003c\/span\u003e\u003cem\u003e \u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSinuated Element\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg?Small\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"Sinuated Element Micastrip Heater Cutout\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebG090.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebG090.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eAn alternative to wound ribbon core heaters is the sinuated heater element. In this type of construction, the heating element resistance wire is sinuated, or \"formed\" back and forth without a middle core layer of mica insulation. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe heating element is then sandwiched between two layers of specially selected mica insulation to provide excellent thermal conductivity and dielectric strength. The sinuated formed element lends itself to lower temperature and watt density applications where high watt density construction is not required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-50 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCommon Applications:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","published_at":"2021-09-08T15:10:11-04:00","created_at":"2021-09-08T14:47:36-04:00","vendor":"Tempco","type":"Replacement Parts","tags":["Electronics","Food \u0026 Beverage","Heaters","Manufacturing","Medical \u0026 Pharmaceutical Production","Plastic Fabrication","Process Heat","Replacement Parts","Tempco"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39461201150029,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"NHL00130","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Tempco Duraband ® (Micaband) Band Heaters","public_title":null,"options":["Default Title"],"price":0,"weight":2268,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater.png?v=1631126858","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-1.png?v=1631215169","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-2.png?v=1631215169","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-3.png?v=1631215169","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-4.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-5.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-6.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-7.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-8.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-9.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-10.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-11.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-12.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-13.png?v=1631215172","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-14.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-15.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-16.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-17.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-18.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-19.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-20.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-21.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-22.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-23.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-24.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-25.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-26.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-27.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-28.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-29.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-30.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-31.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-32.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-33.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-34.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-35.png?v=1631215173","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-36.png?v=1631215173"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater.png?v=1631126858","options":["Title"],"media":[{"alt":null,"id":20944217178189,"position":1,"preview_image":{"aspect_ratio":0.878,"height":600,"width":527,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater.png?v=1631126858"},"aspect_ratio":0.878,"height":600,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater.png?v=1631126858","width":527},{"alt":null,"id":20945853218893,"position":2,"preview_image":{"aspect_ratio":0.8,"height":776,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-1.png?v=1631215169"},"aspect_ratio":0.8,"height":776,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-1.png?v=1631215169","width":621},{"alt":null,"id":20945853251661,"position":3,"preview_image":{"aspect_ratio":0.802,"height":776,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-2.png?v=1631215169"},"aspect_ratio":0.802,"height":776,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-2.png?v=1631215169","width":622},{"alt":null,"id":20945853284429,"position":4,"preview_image":{"aspect_ratio":0.805,"height":770,"width":620,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-3.png?v=1631215169"},"aspect_ratio":0.805,"height":770,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-3.png?v=1631215169","width":620},{"alt":null,"id":20945853317197,"position":5,"preview_image":{"aspect_ratio":0.799,"height":778,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-4.png?v=1631215172"},"aspect_ratio":0.799,"height":778,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-4.png?v=1631215172","width":622},{"alt":null,"id":20945853349965,"position":6,"preview_image":{"aspect_ratio":0.803,"height":773,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-5.png?v=1631215172"},"aspect_ratio":0.803,"height":773,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-5.png?v=1631215172","width":621},{"alt":null,"id":20945853382733,"position":7,"preview_image":{"aspect_ratio":0.799,"height":776,"width":620,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-6.png?v=1631215172"},"aspect_ratio":0.799,"height":776,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-6.png?v=1631215172","width":620},{"alt":null,"id":20945853415501,"position":8,"preview_image":{"aspect_ratio":0.801,"height":777,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-7.png?v=1631215172"},"aspect_ratio":0.801,"height":777,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-7.png?v=1631215172","width":622},{"alt":null,"id":20945853448269,"position":9,"preview_image":{"aspect_ratio":0.801,"height":775,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-8.png?v=1631215172"},"aspect_ratio":0.801,"height":775,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-8.png?v=1631215172","width":621},{"alt":null,"id":20945853481037,"position":10,"preview_image":{"aspect_ratio":0.799,"height":778,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-9.png?v=1631215172"},"aspect_ratio":0.799,"height":778,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-9.png?v=1631215172","width":622},{"alt":null,"id":20945853513805,"position":11,"preview_image":{"aspect_ratio":0.799,"height":778,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-10.png?v=1631215172"},"aspect_ratio":0.799,"height":778,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-10.png?v=1631215172","width":622},{"alt":null,"id":20945853546573,"position":12,"preview_image":{"aspect_ratio":0.798,"height":777,"width":620,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-11.png?v=1631215172"},"aspect_ratio":0.798,"height":777,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-11.png?v=1631215172","width":620},{"alt":null,"id":20945853579341,"position":13,"preview_image":{"aspect_ratio":0.8,"height":776,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-12.png?v=1631215172"},"aspect_ratio":0.8,"height":776,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-12.png?v=1631215172","width":621},{"alt":null,"id":20945853612109,"position":14,"preview_image":{"aspect_ratio":0.793,"height":784,"width":622,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-13.png?v=1631215172"},"aspect_ratio":0.793,"height":784,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-13.png?v=1631215172","width":622},{"alt":null,"id":20945853644877,"position":15,"preview_image":{"aspect_ratio":0.798,"height":778,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-14.png?v=1631215173"},"aspect_ratio":0.798,"height":778,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-14.png?v=1631215173","width":621},{"alt":null,"id":20945853677645,"position":16,"preview_image":{"aspect_ratio":0.801,"height":769,"width":616,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-15.png?v=1631215173"},"aspect_ratio":0.801,"height":769,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-15.png?v=1631215173","width":616},{"alt":null,"id":20945853710413,"position":17,"preview_image":{"aspect_ratio":0.804,"height":766,"width":616,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-16.png?v=1631215173"},"aspect_ratio":0.804,"height":766,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-16.png?v=1631215173","width":616},{"alt":null,"id":20945853743181,"position":18,"preview_image":{"aspect_ratio":0.8,"height":776,"width":621,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-17.png?v=1631215173"},"aspect_ratio":0.8,"height":776,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-17.png?v=1631215173","width":621},{"alt":null,"id":20945853775949,"position":19,"preview_image":{"aspect_ratio":0.794,"height":781,"width":620,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-18.png?v=1631215173"},"aspect_ratio":0.794,"height":781,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-18.png?v=1631215173","width":620},{"alt":null,"id":20945853808717,"position":20,"preview_image":{"aspect_ratio":0.799,"height":867,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-19.png?v=1631215173"},"aspect_ratio":0.799,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-19.png?v=1631215173","width":693},{"alt":null,"id":20945853841485,"position":21,"preview_image":{"aspect_ratio":0.803,"height":864,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-20.png?v=1631215173"},"aspect_ratio":0.803,"height":864,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-20.png?v=1631215173","width":694},{"alt":null,"id":20945853874253,"position":22,"preview_image":{"aspect_ratio":0.796,"height":869,"width":692,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-21.png?v=1631215173"},"aspect_ratio":0.796,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-21.png?v=1631215173","width":692},{"alt":null,"id":20945853907021,"position":23,"preview_image":{"aspect_ratio":0.8,"height":869,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-22.png?v=1631215173"},"aspect_ratio":0.8,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-22.png?v=1631215173","width":695},{"alt":null,"id":20945853939789,"position":24,"preview_image":{"aspect_ratio":0.797,"height":870,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-23.png?v=1631215173"},"aspect_ratio":0.797,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-23.png?v=1631215173","width":693},{"alt":null,"id":20945853972557,"position":25,"preview_image":{"aspect_ratio":0.787,"height":870,"width":685,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-24.png?v=1631215173"},"aspect_ratio":0.787,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-24.png?v=1631215173","width":685},{"alt":null,"id":20945854005325,"position":26,"preview_image":{"aspect_ratio":0.797,"height":869,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-25.png?v=1631215173"},"aspect_ratio":0.797,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-25.png?v=1631215173","width":693},{"alt":null,"id":20945854038093,"position":27,"preview_image":{"aspect_ratio":0.8,"height":868,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-26.png?v=1631215173"},"aspect_ratio":0.8,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-26.png?v=1631215173","width":694},{"alt":null,"id":20945854070861,"position":28,"preview_image":{"aspect_ratio":0.797,"height":869,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-27.png?v=1631215173"},"aspect_ratio":0.797,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-27.png?v=1631215173","width":693},{"alt":null,"id":20945854103629,"position":29,"preview_image":{"aspect_ratio":0.805,"height":867,"width":698,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-28.png?v=1631215173"},"aspect_ratio":0.805,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-28.png?v=1631215173","width":698},{"alt":null,"id":20945854136397,"position":30,"preview_image":{"aspect_ratio":0.8,"height":870,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-29.png?v=1631215173"},"aspect_ratio":0.8,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-29.png?v=1631215173","width":696},{"alt":null,"id":20945854169165,"position":31,"preview_image":{"aspect_ratio":0.798,"height":868,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-30.png?v=1631215173"},"aspect_ratio":0.798,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-30.png?v=1631215173","width":693},{"alt":null,"id":20945854201933,"position":32,"preview_image":{"aspect_ratio":0.8,"height":869,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-31.png?v=1631215173"},"aspect_ratio":0.8,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-31.png?v=1631215173","width":695},{"alt":null,"id":20945854234701,"position":33,"preview_image":{"aspect_ratio":0.801,"height":869,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-32.png?v=1631215173"},"aspect_ratio":0.801,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-32.png?v=1631215173","width":696},{"alt":null,"id":20945854267469,"position":34,"preview_image":{"aspect_ratio":0.8,"height":865,"width":692,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-33.png?v=1631215173"},"aspect_ratio":0.8,"height":865,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-33.png?v=1631215173","width":692},{"alt":null,"id":20945854300237,"position":35,"preview_image":{"aspect_ratio":0.8,"height":869,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-34.png?v=1631215173"},"aspect_ratio":0.8,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-34.png?v=1631215173","width":695},{"alt":null,"id":20945854333005,"position":36,"preview_image":{"aspect_ratio":0.796,"height":872,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-35.png?v=1631215173"},"aspect_ratio":0.796,"height":872,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-35.png?v=1631215173","width":694},{"alt":null,"id":20945854365773,"position":37,"preview_image":{"aspect_ratio":0.797,"height":870,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-36.png?v=1631215173"},"aspect_ratio":0.797,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoDurabandHeater-36.png?v=1631215173","width":693}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-mce-fragment=\"1\"\u003eDuraband is a mica insulated heater incorporating a Low Thermal Expansion Alloy outer sheath that is used as a uniquely designed Built-In Strap.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIt is a proven heater design for good life efficiency and dependability. It assures maintaining the lowest winding temperatures possible, keeping a low-mass heating element assembly for fast heat-up and quick thermal response to controls. It incorporates the Low Thermal Expansion Built-In Strap, a unique design feature originally developed and patented by Tempco.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Temperature:\u003c\/strong\u003e Standard Sheath: 900°F (482°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNominal Watt Density: \u003c\/strong\u003e20-45 W\/in\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e (3-7 W\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e )\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Watt Density:\u003c\/strong\u003e Dependent on heater size and operating temperature.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-27 for calculating maximum watt density, and additional specifications.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul class=\"noBullets\"\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eDual Voltage or 3-Phase:\u003c\/strong\u003e Available depending on heater design\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eMaximum Amperage: \u003c\/strong\u003e\u003c\/em\u003e\u003cem\u003eLead Wire Termination: 12.5A, \u003c\/em\u003e\u003cem\u003eScrew Terminations: 8-32UNF—20A and 10-32UNF—25A\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e +10%, –5%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e +5%, –10%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-24 and 1-25 for additional temperature, and thermal conduction information.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003ePhysical Size Construction Limitations\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e ±1\/16\" (1.59 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eNominal Gap:\u003c\/strong\u003e 3\/8\" (9.5 mm)—If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eSee reference page 1-26 for a listing of Standard Specifications and Tolerances.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eBuilt-In Brackets\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater Width\u003c\/th\u003e\n\u003cth\u003eNumber of Brackets\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\" to 3\" (38-76 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1\/8\" to 5\" (79-127 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5-1\/8\" to 6-7\/8\" (130-145 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\" to 10\" (178-254 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-1\/8\" to 15\" (257-381 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eMinimum ID and Width for Construction\/Clamping Styles\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eMin. ID\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eMin. Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStyle\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e76.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-Jul\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e22.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNSL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eNEL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e31.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1\/2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e38.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTWL\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNB\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/1\/02\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e134.7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNS\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e254\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eRecommended Segments by Inner Diameter\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eNumber of Segments\u003c\/th\u003e\n\u003cth\u003eID Range\u003c\/th\u003e\n\u003cth\u003eID Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15-1\/2\" \u0026amp; Smaller\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm \u0026amp; Smaller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 28\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 711.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 45\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 1143mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 1422.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 1\/2\" to 86\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 2184.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25\" to 96\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e393.7mm to 2438.4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eStock Heaters:\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eFor ordering information, see reference page 1-48. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo order by part number, see reference pages 1-52 through 1-59.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eCustom Engineered\/Manufactured Heaters:\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eFor ordering information, see reference page 1-48. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eNote: Refer to individual descriptions for further ordering information.  Actual heater minimums will be a combination of termination and construction\/strap styles.\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Lead Terminations, see reference pages 1-32 through 1-45\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Construction Styles, see reference pages 1-28, 1-46, and 1-47\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eFor Clamping Variations, see reference pages 1-29 through 1-31\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eOne Piece Band Construction\u003c\/h4\u003e\n\u003ctable style=\"width: 99.4841%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB544.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB544.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe one-piece construction is available on any screw or lead termination and clamping variation. It can be used where band heaters can be slipped over the end of the cylinder.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTwo Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.3863%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB545.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.3863%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Duraband two-piece construction provides a built-in hinge, making handling and installation easier. It is used on large cylinders or where the heater cannot be slipped over the end of the cylinder.  Two-piece band heaters are rated at watts and volts per each half when ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eOne Piece Expandable Band Construction \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.8865%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB546.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.8865%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe one-piece expandable construction is available on any screw or lead and clamping variation and can be used where a one-piece band heater would have to be expanded to fit over the barrel during installation, rather than slipped over the end of the barrel.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n                                                                                                                                \n\u003ch4\u003eType NS: Partial Coverage Band with Built-In Brackets (2 Piece)                               \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB036.jpg?Small\"\u003e              \u003cimg alt=\"Angle of Coverage Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\" width=\"163\" height=\"163\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePartial coverage band heaters are normally required when holes and cutouts will not allow the heater to sufficiently clear the machine obstructions.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of construction is the Two-Piece Band Heater with Built-In Brackets as illustrated. The heater is screwed down to the cylinder at the ends and the built-in Low Thermal Expansion Strap pulls the heater tightly against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard center of hole to edge of heater dimension is 1\/4\". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType PS: Partial Coverage Band with Separate Strap (2 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB037.jpg?Small\"\u003e                \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" alt=\"Angle of Coverage Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe alternate method of partial coverage construction is the One-Piece Band Heater with a separate Two-Piece Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe two-piece strap itself is screwed down at the padded ends, allowing the heater to float between the pads as illustrated. When the strap is tightened, it will pull the heater against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard center of hole to edge of heater dimension is 1\/4\". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n                               \n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType NB: Partial Coverage Band with Built-In Strap (1 Piece)\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 31.6479%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB567.jpg?Small\"\u003e                 \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_TypeNB.jpg?Medium\" alt=\"Type NB Angle of Coverage Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_TypeNB.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 31.6479%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003eAnother alternate method of partial coverage construction.  The one piece with clamp screws on both sides allows it to be secured to anchor points on either side of a barrel without drilling holes into the barrel.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-28 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType RNB: Reverse Band Construction with Bracket Clamping (1 Piece)\u003c\/h4\u003e\n\u003ctable style=\"width: 99.7039%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 13.9662%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 41.0338%;\"\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters 5-1\/2\" diameter and larger.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 5-1\/2\" (139.7 mm) to 10\" (254.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\u003cem\u003eFor ID's greater than 10\" see \u003cstrong\u003eType RNS\u003c\/strong\u003e.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eType RNS: Reverse Band Construction with Bracket Clamping (2 Piece)\u003c\/h4\u003e\n\u003ctable style=\"width: 99.9473%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 32.373%;\"\u003e \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0534.jpg\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 55.627%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters 10\" diameter and larger.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 10\" (254.0 mm) to 20\" (508.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFor ID's greater than 20\", Contact IHS for Assistance.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ch4 data-mce-fragment=\"1\"\u003eType RTWL: Reverse Band Construction with Wedge Lock (1 Piece)   \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9122%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10.4112%;\"\u003e \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebDSC_0535.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 42.5888%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is used to heat cylindrical surfaces from the inside on heaters less than 5\" outside diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eInside Diameter Range:\u003c\/strong\u003e 5-1\/2\" (139.7 mm) to 20\" (508 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWidth Range:\u003c\/strong\u003e 1\" (25.4 mm) to 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 240VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSquare or Rectangular Shape \u003cspan\u003e \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 100.035%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.5072%;\"\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg\" width=\"156\" height=\"156\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB543.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"182\" width=\"182\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110.jpg\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"178\" width=\"178\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110A.jpg\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110A.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"174\" width=\"174\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110B.jpg\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB110B.jpg\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.4928%;\"\u003e\n\u003cp\u003e\u003cem\u003eSquare or Rectangular band heaters are normally used for heating dies on plastic extruders, or the barrels of twin screw extruders. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be made in either one- or two-piece construction but two-piece construction with Style 1 Clamping (see below) is recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWidth Range: \u003c\/strong\u003e1\" to 3-1\/2\" (25.4 - 88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 1 for 2-Piece Heaters (Recommended):\u003c\/strong\u003e bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 25 w\/in\u003csup\u003e2\u003c\/sup\u003e \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 2 for 2-Piece Heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum \"B\" dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 20 w\/in\u003csup\u003e2\u003c\/sup\u003e \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStyle 3 for 1-Piece Heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum \"A\" dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Recommended Watt Density:\u003c\/strong\u003e 25 w\/in\u003csup\u003e2\u003c\/sup\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHexagon Shape \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3577%;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB0101.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB0101.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.3577%;\"\u003e\n\u003cp\u003e\u003cem\u003eHexagon shaped band heaters are used on the hex shaped portion of the nozzle on injection molding machines.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThese types of heaters are strictly made to customer specifications with bent-up flange clamping only.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 1\u003c\/strong\u003e \u003cstrong\u003efor 2-piece heaters:\u003c\/strong\u003e bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible. Maximum Recommended Watt Density: 25 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 2\u003c\/strong\u003e \u003cstrong\u003efor 2-piece heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum “B” dimension of 3.75\" (95.3 mm).\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eMaximum Recommended Watt Density: 20 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStyle 3\u003c\/strong\u003e\u003cstrong\u003e for 1-piece heaters:\u003c\/strong\u003e bent-up flange clamping or built-in strap brackets at the sides requires a minimum “A” dimension of 3.75\" (95.3 mm). Maximum Recommended Watt Density: 25 w\/in2\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eClamping Options:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NB: Standard Built-In Clamping (Low Thermal Expansion), One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type NB Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system. The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NS: Standard Built-In Clamping (Low Thermal Expansion), Two Piece Band\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e                 \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e                  \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" alt=\"Type NB Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NE: Standard Built-In Strap Clamping (Low Thermal Expansion), One Piece Band                                                                                                                               \u003c\/h4\u003e\n\u003ctable style=\"width: 99.2349%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\n\u003cp\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB547.jpg?Small\"\u003e                   \u003cimg height=\"163\" width=\"163\" alt=\"Type NE Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB2.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-28 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType TWL: Wedge Lock, One Piece Band   \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e                                                                      \u003c\/h4\u003e\n\u003ctable style=\"width: 99.8458%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB549.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type TWL drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB9.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB9.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38%;\"\u003e\n\u003cp\u003e\u003cem\u003eWedge Lock clamping is designed for applications where mounting space is severely limited.  It lends itself mainly to small diameter nozzle heaters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-29 and 1-31 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SB: Separate Straps, One Piece Band  \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e                                                                     \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9507%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Type SB Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9507%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SS: Separate Straps, Two Piece Band                                          \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 99.9121%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SE: Separate Straps, One Piece Expandable Band                                                    \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 97.3464%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 97.3464%;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 36%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 36%;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB570.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10.jpg?Medium\"\u003e      \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 36%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-style=\"width: 36%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eThe Separate Strap clamping is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eIt is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLimitations\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-3\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SL: Spring Loaded with Built-In Bracket, One Piece Band                  \u003c\/h4\u003e\n\u003ctable style=\"width: 99.7538%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31%; text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31%; text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSL: Spring Loaded with Built-In Bracket, Two Piece Band     \u003cspan\u003e \u003c\/span\u003e         \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9208%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eNote: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NEL: Spring Loaded with Built-In Bracket, One Piece Expandable Band               \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0244%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB550.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB109.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0244%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIt is recommended for heaters over 12\" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine. The springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-29 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SLQD: Spring Loaded Quick Disconnect, One Piece Band \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.8596%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.8596%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3.5\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSLQD: Spring Loaded Quick Disconnect, Two Piece Band \u003c\/h4\u003e\n\u003ctable style=\"width: 99.7801%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cspan\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This cla\u003c\/em\u003emping style is available with either lead or screw terminal type terminations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NELQD: Spring Loaded Quick Disconnect, One Piece Expandable Band \u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0882%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB578.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"Duraband Spring Loaded Quick Disconnect Clamp Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMBH_ClmpLT_Drw.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0882%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUtilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3.5\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1.25\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LT: Latch and Trunnion, One Piece Band   \u003cspan\u003e \u003c\/span\u003e                                                      \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.4456%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.4456%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation.  \u003c\/em\u003e\u003cem\u003eIt is ideal in absorbing thermal expansion due to the spring loading on the screws. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders.  \u003c\/em\u003e\u003cem\u003eThe outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\" (177.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eNote: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LS: Latch and Trunnion, Two Piece Band     \u003c\/h4\u003e\n\u003ctable style=\"width: 99.5661%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003cbr\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eMinimum Inside Diameter: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e7\" (177.8 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cem\u003eMinimum Width: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e1\u003c\/em\u003e\u003cem\u003e-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LE: Latch and Trunnion, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB035.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB101.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eThe Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.\u003c\/em\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eThe latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLimitations\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\" (177.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n           \n\u003ch4 data-mce-fragment=\"1\"\u003eType FB: Bent-Up Flange (Ears), One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType FS: Bent-Up Flange (Ears), Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType FE: Bent-Up Flange (Ears), One Piece Expandable Band                                         \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB003.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB7.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy.  The Bent-Up Flange design is best suited for narrow band heaters with small diameters.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-30 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Screw Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.3576%;\"\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB548.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.3576%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.4298%;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_2Pc.jpg?Small\"\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.4298%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gaps on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T1: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.557%;\"\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T1_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.557%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals: \u003c\/strong\u003e10-32 standard except 8-32 on heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e      \u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB551.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enext to same gap on each half; center of width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\" (50.8 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10-32 standard except 8-32 on \u0026lt; 1\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003eNote: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T2_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB552.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMb119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMb119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/25A (10-32) or 20A (8-32)\u003c\/p\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, Two Piece Band\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_T3_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB119.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 standard except 8-32 on 2\" to 2-1\/2\" wide heaters \u0026amp; heaters with ID \u0026lt; 3\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.\u003c\/p\u003e\n\u003cp\u003eThe screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3\" (76.2 mm) wide or when C3 terminal box is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-32 and 1-33 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Button Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB553.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003e\u003cspan\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gaps on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B1: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B1_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB571.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size: \u003c\/strong\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/em\u003e\u003cem\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B2: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B2_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/em\u003e\u003cem\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg\" width=\"152\" height=\"152\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB572.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_2Pc.jpg?Small\"\u003e      \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e                        \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size:\u003c\/strong\u003e 10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType B3: Button Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_B3_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB118.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width: \u003c\/strong\u003e2-3\/8\" (60.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScrew Size: \u003c\/strong\u003e10-32 standard except 6-32 on IDs \u0026lt; 5\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (6-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAvailable on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  \u003c\/span\u003eThey are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-34 and 1-35 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Lead Wire Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 198px;\"\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB554.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB554.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 319px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, Two Piece Band\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 199px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_2Pc.jpg?Small\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 318px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width:\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm):\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm):\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.125px;\"\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L1_1PcX.jpg?Small\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 321.875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eStandard Termination Location\u003c\/strong\u003e\u003cspan\u003e: next to gap; center of width\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/4\" (31.8 mm)\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 480V\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\u003ci\u003e\u003cstrong\u003eMaximum Amps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e12.5A\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.344px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB574.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB574.jpg?Small\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 317.656px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e3\/4\" (19.1 mmL\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ctable style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 200.391px;\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_2Pc.jpg?Small\" width=\"153\" height=\"153\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 325.609px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eeach side of each gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L2: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable style=\"width: 533px;\" data-mce-fragment=\"1\" data-mce-style=\"width: 533px;\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 220.531px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px;\"\u003e\n\u003ctd style=\"height: 220.531px; width: 36px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px; width: 36px;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L2_1PcX.jpg?Small\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 220.531px; width: 491px;\" data-mce-fragment=\"1\" data-mce-style=\"height: 220.531px; width: 491px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: 2-1\/2\" (63.5 mm)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts:\u003c\/strong\u003e 480V\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.814%;\"\u003e\n\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB573.jpg?Small\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 47.186%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e same side of gap; edge of width\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.8032%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1968%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of same gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480V each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L4: Straight Lead Wires, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 198.953px;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_L4_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 318.047px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eSame side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-35 and 1-36 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Wire Braid Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                          Type W1                       Type W1T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e         \u003cimg height=\"120\" width=\"120\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e       \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" alt=\"Type W1T\" width=\"120\" height=\"120\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                             W1T                            Type W1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.625px;\"\u003e\n\u003ctd style=\"height: 20.625px;\"\u003e        \u003cimg height=\"120\" width=\"120\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_2Pc.jpg\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1 \u0026amp; W1T: Straight Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                        Type W1T                        Type W1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W1_1PcX.jpg?Small\"\u003e        \u003cimg height=\"130\" width=\"130\" alt=\"Type W1T\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB577.jpg?Medium\"\u003e        \u003cimg height=\"120\" width=\"120\" alt=\"Type W1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB106.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eW1\u003c\/strong\u003e – Braided lead wire crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eW1T\u003c\/strong\u003e – Braided lead wire attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.9352%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB561.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.0648%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segmet for expandable designs.\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSleeving is used for additional protection.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-37 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.2261%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 55.7739%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segment for expandable designs.  \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSleeving is used for additional protection.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.6241%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.3759%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap offset 1\"; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/8\" (28.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1\" from the middle of the segment for expandable designs.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eSleeving is used for additional protection.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.4687%;\"\u003e\n\u003cimg height=\"152\" width=\"152\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB569.jpg?Small\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 58.5313%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  The standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.3371%;\"\u003e \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6629%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eeach side of each gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W3: Single Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7886%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W3_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2114%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e each side of gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eHighly recommended for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1293%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB568.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.8707%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e7\/8\" (22.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7153%;\"\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2847%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W4: Wire Braid Leads On One Side, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.5959%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W4_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.4041%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eA suitable termination for nozzle heating applications.  \u003c\/em\u003e\u003cem\u003eThe standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-37 and 1-38 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: , Right-Angle Wire Braid Leads, 90° to Heater, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.4307%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB565.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.5693%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90° to Heater, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8229%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.1771%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90° to Heater, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9297%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W2M_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 53.0703%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7056%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB566.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.2944%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite of gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.2224%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 53.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each side; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: The minimum heater width with a coupling is 1-1\/2\". If heater width is smaller than 1-1\/2\", heater gap will be used for coupling location.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.7806%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_W5M_1PcX.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.2194%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-39 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Straight Armor Cable Lead Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB557.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT\u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT\u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D\u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E\u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F\u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT\u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width=\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT\u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D\u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E\u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F\u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Straight Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R1_1PcX.jpg?Small\"\u003e               \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB108.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (65.3 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eR1A \u003c\/strong\u003e – Galvanized armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1AT \u003c\/strong\u003e – Galvanized armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1B \u003c\/strong\u003e – Stainless Steel armor cable crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1BT \u003c\/strong\u003e – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1\/2\" and over I.D. and 1-1\/4\" and over width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1C \u003c\/strong\u003e – Galvanized armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1D \u003c\/strong\u003e – SS armor cable, tack welded\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1E \u003c\/strong\u003e – Galvanized armor cable, full silver brazing\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eR1F \u003c\/strong\u003e – SS armor cable, full silver brazing\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB558.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A\u003c\/strong\u003e – Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_2Pc.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A \u003c\/strong\u003e– Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Right-Angle Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R2_1PcX.jpg?Small\"\u003e            \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB116.jpg?Medium\"\u003e  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R2A\u003c\/strong\u003e – Galvanized armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2B\u003c\/strong\u003e – SS armor cable, crimped\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType R2C\u003c\/strong\u003e – Plain leads, no cable\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB559.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: Multiple segment designs are recommended on larger diameter (typically larger than 15\") heaters to improve the clamping force and increase the surface contact between the heater and the barrel for efficient heat transfer.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_2Pc.jpg?Small\"\u003e        \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e      \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: The One-Piece Expandable Band should not be opened and closed more than twice.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R3: Removable Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 167px;\"\u003e\n\u003ctd style=\"height: 167px;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_R3_1PcX.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB117.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6562px;\"\u003e\n\u003ctd style=\"height: 21.6562px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-40 and 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3A –\u003c\/strong\u003e Plain Leads \u0026amp; Female Fitting\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3B –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; Galvanized Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType R3C –\u003c\/strong\u003e Leads, Male Adapter \u0026amp; SS Armor\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations: Lead Wire Spring Strain Relief Terminals\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 96.0152%; text-align: center;\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB576.jpg?Small\" data-mce-selected=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 96.0152%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/4\" (31.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1\/8\" long. The flexible standard leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType S1A –\u003c\/strong\u003e Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1AT –\u003c\/strong\u003e Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1B –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1BT –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width. 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg height=\"153\" width=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_S1_2Pc.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/4\" (31.75 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1\/8\" long. The flexible standard leads are 10\" long with 3\" of fiberglass sleeving.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-41 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType S1A –\u003c\/strong\u003e Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1AT –\u003c\/strong\u003e Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1B –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1\/2\" I.D. and\/or under 1-1\/4\" width 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType S1BT –\u003c\/strong\u003e Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over\/equal 2-1\/2\" I.D. and over\/equal 1-1\/4\" width. 10\" of braid over 12\" of flexible leads is standard.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType S1: Lead Wire Spring Strain Relief, One Piece Expandable Band\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminal Boxes: Standard Terminal Boxes\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A –\u003c\/strong\u003e Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C –\u003c\/strong\u003e w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_2Pc.jpg?Small\"\u003e         \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A –\u003c\/strong\u003e Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C –\u003c\/strong\u003e w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003eType C2D –\u003c\/strong\u003e w\/wire braid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C2: Standard Terminal Boxes, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C2_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB120.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C2A\u003c\/strong\u003e – Box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2B\u003c\/strong\u003e – w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2C\u003c\/strong\u003e – w\/stainless steel armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C2D\u003c\/strong\u003e – w\/wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminal Boxes: Low-Profile Terminal Boxes\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB516.jpg?Small\"\u003e             \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location\u003c\/strong\u003e: next to same gap on each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMax. Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C5: Low-Profile Terminal Boxes, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_C5_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB121.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003enext to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) Heater widths between 1\" and 2-1\/2\" require a minimum ID of 5-1\/2\" or greater\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable with any construction or clamping variation. They are a simple \u0026amp; economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1\/2\" knockouts that will accept standard armor cable connectors. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThey can be field assembled on band heaters that have a center distance between terminal screws of 7\/8\". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10\" of cable or wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-42 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType C5A –\u003c\/strong\u003e box only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5B –\u003c\/strong\u003e w\/galvanized armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5C –\u003c\/strong\u003e w\/SS armor\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5D –\u003c\/strong\u003e w\/wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType C5J –\u003c\/strong\u003e w\/plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Quick Disconnect Plugs: Standard\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 517px;\"\u003e                                                    Type P1M                        Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 163px;\"\u003e\n\u003ctd style=\"height: 163px; width: 517px;\"\u003e   \u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB515.jpg?Small\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1M\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1L\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 517px;\"\u003e                                                     Type P1M                      Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 163px;\"\u003e\n\u003ctd style=\"height: 163px; width: 517px;\"\u003e\n\u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_2Pc.jpg?Small\"\u003e       \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" alt=\"Type P1M\" width=\"140\" height=\"140\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" alt=\"Type P1L\" width=\"140\" height=\"140\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                    Type P1M                       Type P1L \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003e \u003cimg height=\"130\" width=\"130\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P1_1PcX.jpg?Small\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1M\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB125.jpg?Medium\"\u003e     \u003cimg height=\"140\" width=\"140\" alt=\"Type P1L\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebP1L.jpg?Medium\"\u003e                     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e572°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P1K –\u003c\/strong\u003e Cup assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1L –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1M –\u003c\/strong\u003e w\/90° plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1N –\u003c\/strong\u003e w\/str. plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1O –\u003c\/strong\u003e w\/str. plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1P –\u003c\/strong\u003e w\/str. plug \u0026amp; wire braid\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1Q –\u003c\/strong\u003e w\/90° plug \u0026amp; galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1R –\u003c\/strong\u003e w\/90° plug \u0026amp; SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P1S – \u003c\/strong\u003ew\/90° plug \u0026amp; wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eImportant: If width is between 1-1\/2\" and 2\", minimum diameter is 5-1\/2\".  If width is greater than 2\", the minimum diameter is 2\".\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Quick Disconnect Plugs: Low-Profile\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                   Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB519.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P2G\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 38.6562px;\"\u003e\n\u003ctd style=\"height: 38.6562px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                   Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_2Pc.jpg?Small\"\u003e               \u003cimg height=\"193\" width=\"193\" alt=\"Type P2G\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e572\u003c\/span\u003e°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType\u003c\/strong\u003e \u003c\/em\u003e\u003cem\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Quick Disconnect Plugs, Low Profile, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                     Type P2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.4062px;\"\u003e\n\u003ctd style=\"height: 25.4062px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P2_1PcX.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\" alt=\"Type P2G\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB126.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e572\u003c\/span\u003e°F (300°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP2F –\u003c\/strong\u003e Low profile assembly only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2G –\u003c\/strong\u003e w\/straight plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2H –\u003c\/strong\u003e w\/str. plug and galvanized cable\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2J –\u003c\/strong\u003e w\/str. plug and SS cable\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P2K –\u003c\/strong\u003e w\/str. plug and wire braid\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                               Type P3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525.jpg?Small\"\u003e      \u003cimg height=\"193\" width=\"193\" alt=\"Type P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e        \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                        Type P3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_2Pc.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" alt=\"Type P3\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e392\u003c\/span\u003e°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P3: DIN 49458 A\/B Quick Disconnect Plugs, Vertical, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                       Type P3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P3_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB525dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5312px;\"\u003e\n\u003ctd style=\"height: 35.5312px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP3A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3B –\u003c\/strong\u003e Box assembly w\/straight plug\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P3C –\u003c\/strong\u003e Box assembly w\/right-angle plug only\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                    Type P4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" alt=\"Type P4\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.9062px;\"\u003e\n\u003ctd style=\"height: 40.9062px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal,  Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                                                                                    Type P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_2Pc.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e         \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P4: DIN 49458 A\/B Quick Disconnect Plugs, Horizontal,  One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px;\"\u003e                                                                                    Type P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29px;\"\u003e\n\u003ctd style=\"height: 29px;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMicaBand_P4_1PcX.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Type P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB526dwg.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.6562px;\"\u003e\n\u003ctd style=\"height: 28.6562px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Next to gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)                                                           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePlug Electrical Ratings:\u003c\/strong\u003e 2-Pole 3-Wire Grounding\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts: \u003c\/strong\u003e250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAvailable on any construction or clamping variation. These plug assemblies are highly recommended \u0026amp; should be used whenever possible. The combination of plug \u0026amp; cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eType P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-43, 1-44, and 1-45 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eType \u003c\/strong\u003e\u003cstrong\u003eP4A –\u003c\/strong\u003e Box assembly only\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eType P4B –\u003c\/strong\u003e Box assembly with straight plug\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Igloo Ceramic Terminal Covers\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C6, C7, and C8 Igloo Ceramic Terminal Covers\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                Type C6                           Type C7                         Type C8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e       \u003cimg height=\"120\" width=\"120\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB202.jpg?Small\"\u003e          \u003cimg height=\"117\" width=\"117\" alt=\"Type C7\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB203.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB203.jpg?Medium\"\u003e         \u003cimg height=\"117\" width=\"117\" alt=\"Type C8\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB201.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB201.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eIgloo® Ceramic Terminal Covers consist of two individual ceramic parts. Unlike conventional ceramic caps, Igloo fully insulates any standard #8 or #10 terminal lugs used for electrical hook-ups.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-33 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e\u003ci\u003eMinimum Inside Diameter: \u003c\/i\u003e\u003c\/b\u003e\u003ci\u003e2\" (50.8 mm)\u003c\/i\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1-1\/4\" (31.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: To assemble Igloo covers, terminals should be at least 7\/8\" apart.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"MainContent\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThree types of Igloo™ bases are available:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e – Double Port In-Line P\/N CER-101-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e – Double Port 90° P\/N CER-101-10\u003c\/em\u003e6\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e – Single Port P\/N CER-101-107\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eIgloo™caps are available in the following three screw terminal sizes:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-32\u003c\/strong\u003e – P\/N CER-102-101\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-24\u003c\/strong\u003e – P\/N CER-102-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e8-32\u003c\/strong\u003e – P\/N CER-102-105\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: When ordering, specify the type of Igloo and the screw terminal size.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThermocouple Fittings:\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThermocouple Bayonet Adapter\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB014.jpg?Small\"\u003e          \u003cimg height=\"193\" width=\"193\" alt=\"Thermocouple Bayonet Adapter\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\"\u003e    \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA standard Bayonet Adapter facilitates the installation of an external thermocouple with a standard bayonet cap. The standard location for the adapter is 90° from the gap. Specify without through hole for heater sensing or with through hole for load sensing. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor heaters less than 1\" wide order separate strap clamping and utilize the gap for the thermocouple.  Refer to Temperature Sensors for a complete selection of thermocouples available from stock.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThermocouple Coupling\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 98.3666%;\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB038.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\" alt=\"Thermocouple Coupling\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 98.3666%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Thermocouple Coupling facilitates the installation of an external thermocouple with a threaded fitting to sense the temperature of the band. The standard location for the coupling is 90° from the gap. Specify without through hole for heater sensing or with through hole for load sensing.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e \u003c\/h6\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/8-27 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e9\/16\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e11\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/8-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\/8\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eM12–1.75 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Design Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHoles and Cutouts\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.1093%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB009.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 59.8907%;\"\u003e\n\u003cp\u003e\u003cem\u003eHoles and cutouts are normally required in band heaters for clearance for thermocouple probes or holding bolts. An oversize gap can in many cases serve the same purpose, saving the expense of the hole.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eUsing the center of the gap as a starting point, specify the location of the center-point of the hole or cutout in terms of degrees and the distance from the edge of the heater. In addition, state the size of the hole or cutout.  For critical hole and cutout locations, a detailed drawing will be required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHinged Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.5307%;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB040.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 48.4693%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Hinged Two-Piece Band Heater is connected with a continuous hinge for easy installation and removal. This heater can be opened and closed as often as is necessary. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of clamping is latch and trunnion. It is available with any screw or lead variation. When ordering, specify watts and volts each half.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eRing Heaters\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 197px;\"\u003e\n\u003ctd style=\"height: 197px;\"\u003e             \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB044.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB111A.jpg?Medium\" alt=\"Ring Heaters\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB111A.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 43.6562px;\"\u003e\n\u003ctd style=\"height: 43.6562px;\"\u003e\n\u003cp\u003e\u003cem\u003eWhen ordering Ring Heaters, specify inside and outside diameters. If mounting holes are required, specify location and hole size. For critical hole and cutout locations, a detailed drawing will be required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-46 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eCone Shape Heaters\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB015.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" alt=\"Cone Shapes\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB112.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB112.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eCone Shaped Heaters are normally used for special heating applications when heat is required for hoppers or funnels. They are made strictly to customer specifications. The preferred method of attachment is with built-in bracket clamping. When ordering or for quoting purposes, supply a detailed drawing or sample part. Include the top ID, bottom ID, and the vertical rise or heater width.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-47 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSpecial Custom Designs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB505.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eNo other heater band has the design and manufacturing flexibility of mica insulated heaters. Tempco's flexible CNC sheet metal fabricating machines, custom developed engineering programs with built-in intelligence, and experienced and talented engineering staff allow us to push the limits on band heater designs.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAs a custom heating element manufacturer, we recognize that many applications require non-standard and unique designs.  \u003c\/em\u003e\u003cem\u003eWhen you have a special application and you want someone to work who has a \"think outside the box\" mentality, Call us at (844) 862-7880 to discuss additional design options!\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-49 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThree-Phase Option\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eOn very high wattage band heaters it would be advantageous to set up the wiring three-phase to reduce the current load across a single conductor. Three-Phase wiring is available on select clamping\/construction or termination variation (termination location is subject to engineering approval).\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. ID:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eDual Voltage Option\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eBand heaters can be designed using 3-wire series\/parallel circuits for dual voltage applications. Whether the heater is run on the higher or lower voltage, the wattage will be the same. Dual Voltage wiring is available on any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eGround Terminal or Lead\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor those applications requiring a separate ground terminal or lead attached to the heater sheath. A Ground Terminal or Lead is available on any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSingle Phase\/Three Phase Power\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eDuraband Heaters can be designed with multiple circuits to operate single or three-phase.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eBuilt-In Thermocouples\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHeaters can be manufactured with a Built-In Thermocouple to closely control the temperature of the heater. Type J or K thermocouples are available with fiberglass, wire braid or any other required insulation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eAll Stainless Steel Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eAll Stainless Steel Construction  Mica band heaters can be constructed with the external sheath made entirely from stainless steel. This allows the Duraband to reach the maximum temperature of 1200°F (650°C). All Stainless Steel Construction is available on any clamping\/construction or termination variation. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eAdditional Sheath Materials\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 517px;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem\u003eOther sheath materials, such as rust-resistant steel, Monel®, aluminum, or copper are also available for unique applications.\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eElectrical Plugs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               Type P4 Electrical Plug            Type P5 \u0026amp; P9 Electrical Plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\" alt=\"P4 Electrical Plug\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\" alt=\"P5 Electrical Plug\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eIndustry standard NEMA Twist-Lock® electrical plugs are available. The plugs can be attached to fiberglass leads, armor cable or wire braid. Electrical Plugs can be added to any clamping\/construction or termination variation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-48 for additional product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTerminal Lugs\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003cem\u003eVarious types of crimp terminals can be attached to the heater leads to make wiring into applications quick and easy. High temperature 1200°F (649°C) ring terminals and nylon or PVC insulated terminals are available. Spade, ring, and right-angle or straight quick disconnect type terminals can be attached to the leads.\u003c\/em\u003e\u003c\/span\u003e\u003cem\u003e \u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6 data-mce-fragment=\"1\"\u003e\u003c\/h6\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSinuated Element\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB107.jpg?Small\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"Sinuated Element Micastrip Heater Cutout\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebG090.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebG090.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eAn alternative to wound ribbon core heaters is the sinuated heater element. In this type of construction, the heating element resistance wire is sinuated, or \"formed\" back and forth without a middle core layer of mica insulation. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe heating element is then sandwiched between two layers of specially selected mica insulation to provide excellent thermal conductivity and dielectric strength. The sinuated formed element lends itself to lower temperature and watt density applications where high watt density construction is not required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-24 - 27 for additional features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-50 for specific product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-51 for installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003einformation.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCommon Applications:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e"}

Tempco Duraband ® (Micaband) Band Heaters

Product Description

Duraband is a mica insulated heater incorporating a Low Thermal Expansion Alloy outer sheath that is used as a uniquely designed Built-In Strap.

It is a proven heater design for good life efficiency and dependability. It assures maintaining the lowest winding temperatures possible, keeping a low-mass heating element assembly for fast heat-up and quick thermal response to controls. It incorporates the Low Thermal Expansion Built-In Strap, a unique design feature originally developed and patented by Tempco.

Specifications:

Performance Ratings

  • Maximum Temperature: Standard Sheath: 900°F (482°C)
  • Nominal Watt Density: 20-45 W/in2 (3-7 W/cm2 )
  • Maximum Watt Density: Dependent on heater size and operating temperature.
  • See reference page 1-27 for calculating maximum watt density, and additional specifications.

Electrical Ratings

  • Maximum Voltage: 480VAC
  • Dual Voltage or 3-Phase: Available depending on heater design
  • Maximum Amperage: Lead Wire Termination: 12.5A, Screw Terminations: 8-32UNF—20A and 10-32UNF—25A
  • Resistance Tolerance: +10%, –5%
  • Wattage Tolerance: +5%, –10%
  • See reference page 1-24 and 1-25 for additional temperature, and thermal conduction information.

Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

Physical Size Construction Limitations

  • Minimum Width: 3/4" (19.1 mm)
  • Width Tolerance: ±1/16" (1.59 mm)
  • Minimum Inside Diameter: 7/8" (22.1 mm)
  • Nominal Gap: 3/8" (9.5 mm)—If a larger gap is required for probes or thermocouples, specify when ordering.
  • See reference page 1-26 for a listing of Standard Specifications and Tolerances.

Built-In Brackets

Heater Width Number of Brackets
1-1/2" to 3" (38-76 mm) 1
3-1/8" to 5" (79-127 mm) 2
5-1/8" to 6-7/8" (130-145 mm) 3
7" to 10" (178-254 mm) 4
10-1/8" to 15" (257-381 mm) 5

 

Minimum ID and Width for Construction/Clamping Styles

  Min. ID Min. Width
Style in mm in mm
NB 2 50.8 1-1/4 31.8
NS 3 76.2 1-1/4 31.8
NE 2/1/02 63.5 1-1/4 31.8
SB 8-Jul 22.1 3/4 19.1
SS 2 50.8 3/4 19.1
SE 2/1/02 63.5 1-1/4 31.8
FB 1 25.4 3/4 19.1
FS 2 50.8 3/4 19.1
FE 2/1/02 63.5 1-1/4 31.8
SL 4 101.6 1-1/4 31.8
NSL 4 101.6 1-1/4 31.8
NEL 4 101.6 1-1/4 31.8
LT 7 177.8 1-1/2 38.1
LS 7 177.8 1-1/2 38.1
LE 7 177.8 1-1/2 38.1
TWL 1 25.4 1 25.4
RNB 5/1/02 134.7 1 25.4
RNS 10 254 1 25.4

 

Recommended Segments by Inner Diameter

Number of Segments ID Range ID Range
in mm
1 15-1/2" & Smaller 393.7mm & Smaller
2 15 1/2" to 28" 393.7mm to 711.2mm
3 15 1/2" to 45" 393.7mm to 1143mm
4 15 1/2" to 56" 393.7mm to 1422.4mm
6 15 1/2" to 86" 393.7mm to 2184.4mm
8 25" to 96" 393.7mm to 2438.4mm

Ordering Information:

Stock Heaters:

  • For ordering information, see reference page 1-48. 
  • To order by part number, see reference pages 1-52 through 1-59.

Custom Engineered/Manufactured Heaters:

  • For ordering information, see reference page 1-48. 

Note: Refer to individual descriptions for further ordering information.  Actual heater minimums will be a combination of termination and construction/strap styles.

  • For Lead Terminations, see reference pages 1-32 through 1-45
  • For Construction Styles, see reference pages 1-28, 1-46, and 1-47
  • For Clamping Variations, see reference pages 1-29 through 1-31

Design Features:

One Piece Band Construction

 

The one-piece construction is available on any screw or lead termination and clamping variation. It can be used where band heaters can be slipped over the end of the cylinder.

  • See reference pages 1-24 - 27 for additional features and specifications.
  • See reference page 1-28 for specific product information.
  • See reference page 1-51 for installation recommendations.

Two Piece Band Construction

 /Tempco/Data-Assets/01-Band-Images/WebB545.jpg

The Duraband two-piece construction provides a built-in hinge, making handling and installation easier. It is used on large cylinders or where the heater cannot be slipped over the end of the cylinder.  Two-piece band heaters are rated at watts and volts per each half when ordering.

  • See reference pages 1-24 - 27 for additional features and specifications.
  • See reference page 1-28 for specific product information.
  • See reference page 1-51 for installation recommendations.

One Piece Expandable Band Construction 

 /Tempco/Data-Assets/01-Band-Images/WebB546.jpg

The one-piece expandable construction is available on any screw or lead and clamping variation and can be used where a one-piece band heater would have to be expanded to fit over the barrel during installation, rather than slipped over the end of the barrel.

  • See reference pages 1-24 - 27 for additional features and specifications.
  • See reference page 1-28 for specific product information.
  • See reference page 1-51 for installation recommendations.
                                                                                                                                    

    Type NS: Partial Coverage Band with Built-In Brackets (2 Piece)                               

                  /Tempco/Data-Assets/01-Band-Images/WebB036.jpg              Angle of Coverage Drawing

    Partial coverage band heaters are normally required when holes and cutouts will not allow the heater to sufficiently clear the machine obstructions.

    The preferred method of construction is the Two-Piece Band Heater with Built-In Brackets as illustrated. The heater is screwed down to the cylinder at the ends and the built-in Low Thermal Expansion Strap pulls the heater tightly against the cylinder being heated.

    The standard center of hole to edge of heater dimension is 1/4". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.

    • See reference pages 1-24 - 27 for additional features and specifications.
    • See reference page 1-28 for specific product information.
    • See reference page 1-51 for installation recommendations.

    Type PS: Partial Coverage Band with Separate Strap (2 Piece)

                  /Tempco/Data-Assets/01-Band-Images/WebB037.jpg                Angle of Coverage Drawing

    The alternate method of partial coverage construction is the One-Piece Band Heater with a separate Two-Piece Strap.

    The two-piece strap itself is screwed down at the padded ends, allowing the heater to float between the pads as illustrated. When the strap is tightened, it will pull the heater against the cylinder being heated.

    The standard center of hole to edge of heater dimension is 1/4". When ordering, please provide the angle of coverage from center to center of the mounting screw holes as shown.

    • See reference pages 1-24 - 27 for additional features and specifications.
    • See reference page 1-28 for specific product information.
    • See reference page 1-51 for installation recommendations.
                                   

    Type NB: Partial Coverage Band with Built-In Strap (1 Piece)

                   /Tempco/Data-Assets/01-Band-Images/WebB567.jpg                 Type NB Angle of Coverage Drawing

    Another alternate method of partial coverage construction.  The one piece with clamp screws on both sides allows it to be secured to anchor points on either side of a barrel without drilling holes into the barrel.

    • See reference pages 1-24 - 27 for additional features and specifications.
    • See reference page 1-28 for specific product information.
    • See reference page 1-51 for installation recommendations.

    Type RNB: Reverse Band Construction with Bracket Clamping (1 Piece)

     /Tempco/Data-Assets/01-Band-Images/WebDSC_0534.jpg

    This construction style is used to heat cylindrical surfaces from the inside on heaters 5-1/2" diameter and larger.

    • See reference pages 1-24 - 27 for additional features and specifications.
    • See reference page 1-31 for specific product information.
    • See reference page 1-51 for installation recommendations.

      Limitations

      • Inside Diameter Range: 5-1/2" (139.7 mm) to 10" (254.0 mm)
      • Width Range: 1" (25.4 mm) to 3-1/2" (88.9 mm)
      • Maximum Voltage: 240VAC
      • For ID's greater than 10" see Type RNS.

        Type RNS: Reverse Band Construction with Bracket Clamping (2 Piece)

         

        This construction style is used to heat cylindrical surfaces from the inside on heaters 10" diameter and larger.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Inside Diameter Range: 10" (254.0 mm) to 20" (508.0 mm)
        • Width Range: 1" (25.4 mm) to 3-1/2" (88.9 mm)
        • Maximum Voltage: 240VAC
        • For ID's greater than 20", Contact IHS for Assistance.
         

        Type RTWL: Reverse Band Construction with Wedge Lock (1 Piece)   

         /Tempco/Data-Assets/01-Band-Images/WebDSC_0535.jpg

        This construction style is used to heat cylindrical surfaces from the inside on heaters less than 5" outside diameter.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Inside Diameter Range: 5-1/2" (139.7 mm) to 20" (508 mm)
        • Width Range: 1" (25.4 mm) to 3-1/2" (88.9 mm)
        • Maximum Voltage: 240VAC

        Square or Rectangular Shape  

         /Tempco/Data-Assets/01-Band-Images/WebB543.jpg

        Square or Rectangular band heaters are normally used for heating dies on plastic extruders, or the barrels of twin screw extruders.

        They can be made in either one- or two-piece construction but two-piece construction with Style 1 Clamping (see below) is recommended.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-47 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Width Range: 1" to 3-1/2" (25.4 - 88.9 mm)
        • Style 1 for 2-Piece Heaters (Recommended): bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible.
        • Maximum Recommended Watt Density: 25 w/in2
        • Style 2 for 2-Piece Heaters: bent-up flange clamping or built-in strap brackets at the sides requires a minimum "B" dimension of 3.75" (95.3 mm).
        • Maximum Recommended Watt Density: 20 w/in2
        • Style 3 for 1-Piece Heaters: bent-up flange clamping or built-in strap brackets at the sides requires a minimum "A" dimension of 3.75" (95.3 mm).
        • Maximum Recommended Watt Density: 25 w/in2

        Hexagon Shape  

        Hexagon shaped band heaters are used on the hex shaped portion of the nozzle on injection molding machines.

        These types of heaters are strictly made to customer specifications with bent-up flange clamping only.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-47 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Style 1 for 2-piece heaters: bent-up flange clamping at the corners provides the most uniform clamping force and should be used whenever possible. Maximum Recommended Watt Density: 25 w/in2

        Style 2 for 2-piece heaters: bent-up flange clamping or built-in strap brackets at the sides requires a minimum “B” dimension of 3.75" (95.3 mm).
        Maximum Recommended Watt Density: 20 w/in2

        Style 3 for 1-piece heaters: bent-up flange clamping or built-in strap brackets at the sides requires a minimum “A” dimension of 3.75" (95.3 mm). Maximum Recommended Watt Density: 25 w/in2

        Clamping Options:

        Type NB: Standard Built-In Clamping (Low Thermal Expansion), One Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB547.jpg              Type NB Drawing

        The Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system. The Duraband with Built-In Strap is standard on many designs.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-28 and 31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.8 mm)

        Type NS: Standard Built-In Clamping (Low Thermal Expansion), Two Piece Band

                         /Tempco/Data-Assets/01-Band-Images/WebB547.jpg                  Type NB Drawing

        The Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-28 and 1-31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

      • Minimum Inside Diameter: 2" (50.8 mm)
      • Minimum Width: 1-1/4" (31.8 mm)
      • Type NE: Standard Built-In Strap Clamping (Low Thermal Expansion), One Piece Band                                                                                                                               

                       /Tempco/Data-Assets/01-Band-Images/WebB547.jpg                   Type NE Drawing

        The Built-In Strap eliminates the use of awkward-to-handle separate straps, providing more drawing power than any other type of clamping system.  The Duraband with Built-In Strap is standard on many designs.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-28 and 1-31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)

        Type TWL: Wedge Lock, One Piece Band                                                                          

                      /Tempco/Data-Assets/01-Band-Images/WebB549.jpg              Type TWL drawing

        Wedge Lock clamping is designed for applications where mounting space is severely limited.  It lends itself mainly to small diameter nozzle heaters.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-29 and 1-31 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 1" (25.4 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Width: 3-1/2" (88.9 mm)

        Type SB: Separate Straps, One Piece Band                                                                        

                      /Tempco/Data-Assets/01-Band-Images/WebB570.jpg              Type SB Drawing

        The Separate Strap clamping is available with any screw or lead termination and construction variation.

        It is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 7/8" (22.2 mm)
        • Minimum Width: 3/4" (19.1 mm)

        Type SS: Separate Straps, Two Piece Band                                          

                      /Tempco/Data-Assets/01-Band-Images/WebB570.jpg              

        The Separate Strap clamping is available with any screw or lead termination and construction variation.

        It is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 3/4" (19.1 mm)

        Type SE: Separate Straps, One Piece Expandable Band                                                    

                      /Tempco/Data-Assets/01-Band-Images/WebB570.jpg                    

        The Separate Strap clamping is available with any screw or lead termination and construction variation.

        It is strongly recommended that the Duraband with Built-In Strap design be used whenever possible because it provides more drawing power than any other type of clamping system.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-3/4" (31.8 mm)

        Type SL: Spring Loaded with Built-In Bracket, One Piece Band                  

                      /Tempco/Data-Assets/01-Band-Images/WebB550.jpg              

        The Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.

        It is recommended for heaters over 12" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.

        The springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 4" (101.6 mm)
        • Minimum Width: 1-1/4" (31.8 mm)

        Type NSL: Spring Loaded with Built-In Bracket, Two Piece Band               

                      /Tempco/Data-Assets/01-Band-Images/WebB550.jpg              

        The Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.

        It is recommended for heaters over 12" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine.

        The springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 4" (101.6 mm)
        • Minimum Width: 1-1/4" (31.8 mm)

        Note: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.

        Type NEL: Spring Loaded with Built-In Bracket, One Piece Expandable Band               

                      /Tempco/Data-Assets/01-Band-Images/WebB550.jpg              

        The Heavy Duty Stainless Steel Spring with Built-In Bracket is a variation on the basic Duraband design. It is available with any screw or lead termination and construction variation.

        It is recommended for heaters over 12" in diameter, and for any diameter heater used in the vertical position, to prevent the heater from slipping off the machine. The springs provide constant tension, therefore maintaining optimum surface contact against the cylinder being heated.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-29 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 4" (101.6 mm)
        • Minimum Width: 1-1/4" (31.8 mm)

        Type SLQD: Spring Loaded Quick Disconnect, One Piece Band 

                      /Tempco/Data-Assets/01-Band-Images/WebB578.jpg              Duraband Spring Loaded Quick Disconnect Clamp Drawing

        This construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.

        Utilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.

        The spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 3.5" (88.9 mm)
        • Minimum Width: 1.25" (31.75 mm)

        Type NSLQD: Spring Loaded Quick Disconnect, Two Piece Band 

                      /Tempco/Data-Assets/01-Band-Images/WebB578.jpg              Duraband Spring Loaded Quick Disconnect Clamp Drawing

        This construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.

        Utilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.

        The spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 4" (101.6 mm)
        • Minimum Width: 1.25" (31.75 mm)

        Type NELQD: Spring Loaded Quick Disconnect, One Piece Expandable Band 

                      /Tempco/Data-Assets/01-Band-Images/WebB578.jpg              Duraband Spring Loaded Quick Disconnect Clamp Drawing

        This construction style is a hybrid between the Spring Loaded Clamp with Built-In Bracket and the Latch and Trunnion style clamping.

        Utilizing a built in bracket and heavy duty flanges, this clamping style is durable and easy to work with in the field.

        The spring provides relief for thermal expansion and provides strong clamping for the band. This clamping style is available with either lead or screw terminal type terminations.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 3.5" (88.9 mm)
        • Minimum Width: 1.25" (31.75 mm)

        Type LT: Latch and Trunnion, One Piece Band                                                          

                      /Tempco/Data-Assets/01-Band-Images/WebB035.jpg              

        The Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation.  It is ideal in absorbing thermal expansion due to the spring loading on the screws.

        The latch fully opens, facilitating installation on large diameter cylinders.  The outer sheath is made from a Low Thermal Expansion alloy.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 7" (177.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)

        Note: The number of straps is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.

        Type LS: Latch and Trunnion, Two Piece Band     

                      /Tempco/Data-Assets/01-Band-Images/WebB035.jpg              

        The Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.

        The latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 7" (177.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)

        Type LE: Latch and Trunnion, One Piece Expandable Band

                      /Tempco/Data-Assets/01-Band-Images/WebB035.jpg              
        The Latch and Trunnion Clamping System is available with any screw or lead termination and construction variation. It is ideal in absorbing thermal expansion due to the spring loading on the screws.

        The latch fully opens, facilitating installation on large diameter cylinders. The outer sheath is made from a Low Thermal Expansion alloy.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 7" (177.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
                   

        Type FB: Bent-Up Flange (Ears), One Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB003.jpg              

        The Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameters.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 1" (25.4 mm)
        • Minimum Width: 3/4" (19.1 mm)

        Type FS: Bent-Up Flange (Ears), Two Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB003.jpg              

        The Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy. The Bent-Up Flange design is best suited for narrow band heaters with small diameter.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 3/4" (19.1 mm)

         

        Type FE: Bent-Up Flange (Ears), One Piece Expandable Band                                         

                      /Tempco/Data-Assets/01-Band-Images/WebB003.jpg              

        The Bent-Up Flange clamping is available with any screw or lead termination and construction variation. The outer sheath is made from a Low Thermal Expansion alloy.  The Bent-Up Flange design is best suited for narrow band heaters with small diameters.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-30 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Limitations

        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
         

        Electrical Terminations: Screw Terminals

        Type T1: Screw Terminals, One Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB548.jpg              
        • Standard Termination Location: each side of gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 7/8" (22.2 mm)
        • Post Terminals: 10-32 standard except 8-32 on < 1" wide heaters & heaters with ID < 3"
        • Max. Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type T1: Screw Terminals, Two Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T1_2Pc.jpg              
        • Standard Termination Location: next to gaps on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 7/8" (22.2 mm)
        • Post Terminals: 10-32 standard except 8-32 on < 1" wide heaters & heaters with ID < 3"
        • Max. Volts/Amps: 480VAC/25A (10-32) or 20A (8-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type T1: Screw Terminals, One Piece Expandable Band

                      /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T1_1PcX.jpg              
        • Standard Termination Location: each side of gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Post Terminals: 10-32 standard except 8-32 on heaters with ID < 3"
        • Max. Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Considered standard on most band heaters unless otherwise specified.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Note: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.

              

        Type T2: Screw Terminals, One Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB551.jpg              

        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 7/8" (22.2 mm)
        • Post Terminals: 10-32 standard except 8-32 on < 1" wide heaters & heaters with ID < 3"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Note: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.

        Type T2: Screw Terminals, Two Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T2_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 7/8" (22.2 mm)
        • Post Terminals: 10-32 standard except 8-32 on < 1" wide heaters & heaters with ID < 3"
        • Max. Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Note: The number of weld-on brackets is dependent on heater width. Tempco recommends the use of the largest bolt size that clearance allows.

        Type T2: Screw Terminals, One Piece Expandable Band

                      /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T2_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Post Terminals: 10-32 standard except 8-32 on heaters with ID < 3"
        • Max. Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  Recommended for narrow band heaters where screw terminals are preferred or the C2 terminal box protection is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type T3: Screw Terminals, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB552.jpg              
        • Standard Termination Location: next to gap; across center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 2" (50.8 mm)
        • Post Terminals: 10-32 standard except 8-32 on 2" to 2-1/2" wide heaters & heaters with ID < 3"

        Maximum Volts/Amps: 480VAC/25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3" (76.2 mm) wide or when C3 terminal box is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type T3: Screw Terminals, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T3_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; across center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 2" (50.8 mm)
        • Post Terminals: 10-32 standard except 8-32 on 2" to 2-1/2" wide heaters & heaters with ID < 3"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3" (76.2 mm) wide or when C3 terminal box is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type T3: Screw Terminals, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_T3_1PcX.jpg              
        • Standard Termination Location: next to gap; across center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 2" (50.8 mm)
        • Post Terminals: 10-32 standard except 8-32 on 2" to 2-1/2" wide heaters & heaters with ID < 3"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing.

        The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.  The preferred design on band heaters over 3" (76.2 mm) wide or when C3 terminal box is required.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-32 and 1-33 for specific product information.
        • See reference page 1-51 for installation recommendations.

         

        Electrical Terminations: Button Terminals

         

        Type B1: Button Terminals, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB553.jpg              
        • Standard Termination Location: each side of gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts: 480VAC
        • Maximum Amps: 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B1: Button Terminals, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B1_2Pc.jpg              
        • Standard Termination Location: next to gaps on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B1: Button Terminals, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B1_1PcX.jpg              
        • Standard Termination Location: each side of gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B2: Button Terminals, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB571.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts: 480VAC
        • Maximum Amps: 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces. They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B2: Button Terminals, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B2_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B2: Button Terminals, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B2_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/2" (38.1 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B3: Button Terminals, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB572.jpg              
        • Standard Termination Location: next to gap; across center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 2-3/8" (60.3 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts: 480VAC
        • Maximum Amps: 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B3: Button Terminals, Two Piece Band

                        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B3_2Pc.jpg                              
        • Standard Termination Location: next to same gap on each half; across center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 2-3/8" (60.3 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32) each half

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type B3: Button Terminals, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_B3_1PcX.jpg              
        • Standard Termination Location: next to gap; across center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 2-3/8" (60.3 mm)
        • Screw Size: 10-32 standard except 6-32 on IDs < 5"
        • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (6-32)

        Available on any clamping or construction variation, the specially designed Stainless Steel Button Terminals are internally connected to the heater and are resistant to over-torquing while offering a low profile for tight spaces.  They are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-34 and 1-35 for specific product information.
        • See reference page 1-51 for installation recommendations.

         

        Electrical Terminations: Straight Lead Wire Lead Terminals

         

        Type L1: Straight Lead Wires, One Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebB554.jpg

        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L1: Straight Lead Wires, Two Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L1_2Pc.jpg

        • Standard Termination Location: next to same gap on each half; center of width:
        • Minimum Inside Diameter: 2" (50.8 mm):
        • Minimum Width: 1" (25.4 mm):
        • Maximum Volts: 480V each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L1: Straight Lead Wires, One Piece Expandable Band

        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L1_1PcX.jpg

        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480V
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the lead wires exit through a brass eyelet. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L2: Straight Lead Wires, One Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebB574.jpg

        • Standard Termination Location: each side of gap; edge of width
        • Minimum Inside Diameter: 7/8" (22.2 mm)
        • Minimum Width: 3/4" (19.1 mmL
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L2: Straight Lead Wires, Two Piece Band

         

        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L2_2Pc.jpg

        • Standard Termination Location: each side of each gap; edge of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 3/4" (19.1 mm)
        • Maximum Volts: 480V each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L2: Straight Lead Wires, One Piece Expandable Band

        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L2_1PcX.jpg

        •  Standard Termination Location: each side of gap; edge of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480V
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the L2 is the preferred termination on all small diameter and small width band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L4: Straight Lead Wires, One Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebB573.jpg 
        • Standard Termination Location: same side of gap; edge of width
        • Minimum Inside Diameter: 7/8" (22.2 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L4: Straight Lead Wires, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L4_2Pc.jpg
        • Standard Termination Location: each side of same gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480V each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type L4: Straight Lead Wires, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_L4_1PcX.jpg
        • Standard Termination Location: Same side of gap; edge of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation.  Note that the L4 is a suitable lead termination for small band heaters. The standard flexible leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-35 and 1-36 for specific product information.
        • See reference page 1-51 for installation recommendations.

         

        Electrical Terminations: Straight Wire Braid Lead Terminals

        Type W1 & W1T: Straight Wire Braid Leads, One Piece Band

                                                                  Type W1                       Type W1T
                 Type W1T        Type W1       Type W1T
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        W1 – Braided lead wire crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        W1T – Braided lead wire attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.

        Type W1 & W1T: Straight Wire Braid Leads, Two Piece Band

                                                                     W1T                            Type W1
                /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W1_2Pc.jpg        Type W1T        Type W1
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        W1 – Braided lead wire crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        W1T – Braided lead wire attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.

        Type W1 & W1T: Straight Wire Braid Leads, One Piece Expandable Band

                                                                Type W1T                        Type W1
                /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W1_1PcX.jpg        Type W1T        Type W1
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        W1 – Braided lead wire crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        W1T – Braided lead wire attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.

        Type W2: Wire Braid Leads, One Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebB561.jpg
        • Standard Termination Location: opposite the gap; edge of width
        • Minimum Inside Diameter: 7/8" (22.2 mm)
        • Minimum Width: 1-1/8" (28.6 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        The W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1" from the middle of the segmet for expandable designs.

        Sleeving is used for additional protection.
        The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-37 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W2: Wire Braid Leads, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W2_2Pc.jpg
        • Standard Termination Location: center of each half; edge of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/8" (28.6 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        The W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1" from the middle of the segment for expandable designs. 

        Sleeving is used for additional protection.
        The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W2: Wire Braid Leads, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W2_1PcX.jpg
        • Standard Termination Location: opposite the gap offset 1"; edge of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/8" (28.6 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        The W2 wire braid exits at the middle of the segment on 1 and 2 piece designs and offset 1" from the middle of the segment for expandable designs.
        Sleeving is used for additional protection.  The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W3: Single Wire Braid Leads, One Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebB569.jpg 
        • Standard Termination Location: each side of gap; edge of width
        • Minimum Inside Diameter: 3/4" (19.1 mm)
        • Minimum Width: 7/8" (22.2 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Highly recommended for nozzle heating applications.  The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W3: Single Wire Braid Leads, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W3_2Pc.jpg
        • Standard Termination Location: each side of each gap; edge of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 3/4" (19.1 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Highly recommended for nozzle heating applications.  The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W3: Single Wire Braid Leads, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W3_1PcX.jpg
        • Standard Termination Location: each side of gap; edge of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Highly recommended for nozzle heating applications.  The standard leads are 10" of wire braid over 12" of flexible leads with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W4: Wire Braid Leads On One Side, One Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebB568.jpg
        • Standard Termination Location: next to gap; edge of width
        • Minimum Inside Diameter: 7/8" (22.2 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        A suitable termination for nozzle heating applications.  The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W4: Wire Braid Leads On One Side, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W4_2Pc.jpg
        • Standard Termination Location: next to same gap on each half; edge of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        A suitable termination for nozzle heating applications. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W4: Wire Braid Leads On One Side, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W4_1PcX.jpg
        • Standard Termination Location: next to gap; edge of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        A suitable termination for nozzle heating applications.  The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-37 and 1-38 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W2M: , Right-Angle Wire Braid Leads, 90° to Heater, One Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebB565.jpg
        • Standard Termination Location: opposite of gap; center of width
        • Minimum Inside Diameter: 1-1/2" (38.1 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W2M: Right-Angle Wire Braid Leads, 90° to Heater, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W2M_2Pc.jpg
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W2M: Right-Angle Wire Braid Leads, 90° to Heater, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W2M_1PcX.jpg
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebB566.jpg
        • Standard Termination Location: opposite of gap; center of width
        • Minimum Inside Diameter: 1-1/2" (38.1 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type W5M: Right-Angle Wire Braid Leads, Parallel to Heater, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W5M_2Pc.jpg
        • Standard Termination Location: next to same gap on each side; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC each half
        • Maximum Amps: 12.5A each half

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Note: The minimum heater width with a coupling is 1-1/2". If heater width is smaller than 1-1/2", heater gap will be used for coupling location.

        Type W5M: Right-Angle Wire Braid Leads, Parallel to Heater, One Piece Expandable Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_W5M_1PcX.jpg
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Wire braid leads offer sharp bending not possible with armor cable.

        Stainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-39 for specific product information.
        • See reference page 1-51 for installation recommendations.

         

        Electrical Terminations: Straight Armor Cable Lead Terminals

        Type R1: Straight Armor Cable, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB557.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 1-1/2" (38.1 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        R1A – Galvanized armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        R1AT – Galvanized armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1B – Stainless Steel armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width
        R1BT – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1C – Galvanized armor cable, tack welded
        R1D – SS armor cable, tack welded
        R1E – Galvanized armor cable, full silver brazing
        R1F – SS armor cable, full silver brazing

        Type R1: Straight Armor Cable, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R1_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • Maximum Volts/Amps: 480VAC/12.5A each half

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        R1A – Galvanized armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        R1AT – Galvanized armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1B – Stainless Steel armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width=
        R1BT – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1C – Galvanized armor cable, tack welded
        R1D – SS armor cable, tack welded
        R1E – Galvanized armor cable, full silver brazing
        R1F – SS armor cable, full silver brazing

        Type R1: Straight Armor Cable, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R1_1PcX.jpg               
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (65.3 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts/Amps: 480VAC/12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        R1A  – Galvanized armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        R1AT  – Galvanized armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1B  – Stainless Steel armor cable crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width
        R1BT  – Stainless Steel armor cable attached with a threaded fitting for heaters with 2-1/2" and over I.D. and 1-1/4" and over width.
        R1C  – Galvanized armor cable, tack welded
        R1D  – SS armor cable, tack welded
        R1E  – Galvanized armor cable, full silver brazing
        R1F  – SS armor cable, full silver brazing

        Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

        Type R2: Right-Angle Armor Cable, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB558.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 1-1/2" (38.1 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R2A – Galvanized armor cable, crimped
        Type R2B – SS armor cable, crimped
        Type R2C – Plain leads, no cable

        Type R2: Right-Angle Armor Cable, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R2_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts/Amps: 480VAC/12.5A each half

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R2A – Galvanized armor cable, crimped
        Type R2B – SS armor cable, crimped
        Type R2C – Plain leads, no cable

        Type R2: Right-Angle Armor Cable, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R2_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts/Amps: 480VAC/12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R2A – Galvanized armor cable, crimped
        Type R2B – SS armor cable, crimped
        Type R2C – Plain leads, no cable

        Type R3: Removable Armor Cable, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB559.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 1-1/2" (38.1 mm)
        • Minimum Width: 1-1/4" (31.7 mm)
        • Maximum Volts/Amps: 480VAC/12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R3A – Plain Leads & Female Fitting

        Type R3B – Leads, Male Adapter & Galvanized Armor

        Type R3C – Leads, Male Adapter & SS Armor

        Important: Multiple segment designs are recommended on larger diameter (typically larger than 15") heaters to improve the clamping force and increase the surface contact between the heater and the barrel for efficient heat transfer.

        Type R3: Removable Armor Cable, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R3_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.7 mm)
        • Maximum Volts/Amps: 480VAC/12.5A each half

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R3A – Plain Leads & Female Fitting

        Type R3B – Leads, Male Adapter & Galvanized Armor

        Type R3C – Leads, Male Adapter & SS Armor

        Important: The One-Piece Expandable Band should not be opened and closed more than twice.

        Type R3: Removable Armor Cable, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_R3_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts/Amps: 480VAC/12.5A

        Available on any clamping or construction variation. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference pages 1-40 and 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type R3A – Plain Leads & Female Fitting

        Type R3B – Leads, Male Adapter & Galvanized Armor

        Type R3C – Leads, Male Adapter & SS Armor

         

        Electrical Terminations: Lead Wire Spring Strain Relief Terminals

        Type S1: Lead Wire Spring Strain Relief, One Piece Band

        /Tempco/Data-Assets/01-Band-Images/WebB576.jpg
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.8 mm)
        • Maximum Volts: 480VAC
        • Maximum Amps: 12.5A

        A strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1/8" long. The flexible standard leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type S1A – Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        Type S1AT – Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over/equal 2-1/2" I.D. and over/equal 1-1/4" width.
        Type S1B – Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width 10" of braid over 12" of flexible leads is standard.
        Type S1BT – Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over/equal 2-1/2" I.D. and over/equal 1-1/4" width. 10" of braid over 12" of flexible leads is standard.

        Type S1: Lead Wire Spring Strain Relief, Two Piece Band

         /Tempco/Data-Assets/01-Band-Images/WebMicaBand_S1_2Pc.jpg
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/4" (31.75 mm)
        • Maximum Volts/Amps: 480VAC/12.5A each half

        A strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-1/8" long. The flexible standard leads are 10" long with 3" of fiberglass sleeving.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-41 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type S1A – Plain Leads and Strain Relief Spring crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width.
        Type S1AT – Plain Leads and Strain Relief Spring attached with a threaded fitting for heaters over/equal 2-1/2" I.D. and over/equal 1-1/4" width.
        Type S1B – Stainless Steel Wire Braided Leads and Strain Relief Spring crimped in place for heaters under 2-1/2" I.D. and/or under 1-1/4" width 10" of braid over 12" of flexible leads is standard.
        Type S1BT – Stainless Steel Wire Braided Leads and Strain Relief Spring attached with a threaded fitting for heaters over/equal 2-1/2" I.D. and over/equal 1-1/4" width. 10" of braid over 12" of flexible leads is standard.

        Type S1: Lead Wire Spring Strain Relief, One Piece Expandable Band

        Electrical Terminal Boxes: Standard Terminal Boxes

        Type C2: Standard Terminal Boxes, One Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebB516.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater.
        • Maximum Volts/Amps: 480VAC/25A

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C2A – Box only
        Type C2B – w/galvanized armor
        Type C2C – w/stainless steel armor
        Type C2D – w/wire braid

        Type C2: Standard Terminal Boxes, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_C2_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 3" (76.2 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater.
        • Max. Volts/Amps: 480VAC/25A each half

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C2A – Box only
        Type C2B – w/galvanized armor
        Type C2C – w/stainless steel armor
        Type C2D – w/wire braid

        Type C2: Standard Terminal Boxes, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_C2_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater.
        • Maximum Volts/Amps: 480VAC/25A

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C2A – Box only
        Type C2B – w/galvanized armor
        Type C2C – w/stainless steel armor
        Type C2D – w/wire braid

         

        Electrical Terminal Boxes: Low-Profile Terminal Boxes

        Type C5: Low-Profile Terminal Boxes, One Piece Band

                      /Tempco/Data-Assets/01-Band-Images/WebB516.jpg               
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater.
        • Maximum Volts/Amps: 480VAC/25A

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C5A – box only
        Type C5B – w/galvanized armor
        Type C5C – w/SS armor
        Type C5D – w/wire braid
        Type C5J – w/plain leads

        Type C5: Low-Profile Terminal Boxes, Two Piece Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_C5_2Pc.jpg              
        • Standard Termination Location: next to same gap on each half; center of width
        • Minimum Inside Diameter: 3" (76.2 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater.
        • Max. Volts/Amps: 480VAC/25A each half

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C5A – box only
        Type C5B – w/galvanized armor
        Type C5C – w/SS armor
        Type C5D – w/wire braid
        Type C5J – w/plain leads

        Type C5: Low-Profile Terminal Boxes, One Piece Expandable Band

                       /Tempco/Data-Assets/01-Band-Images/WebMicaBand_C5_1PcX.jpg              
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1" (25.4 mm) Heater widths between 1" and 2-1/2" require a minimum ID of 5-1/2" or greater
        • Maximum Volts/Amps: 480VAC/25A

        Available with any construction or clamping variation. They are a simple & economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations. The Heavy Duty Terminal Boxes have 1/2" knockouts that will accept standard armor cable connectors.

        They can be field assembled on band heaters that have a center distance between terminal screws of 7/8". Boxes can be pre-wired with galvanized armor, stainless steel armor, wire braid or plain leads. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory. The standard leads are 10" of cable or wire braid over 12" of flexible leads.

        • See reference pages 1-24 - 27 for additional features and specifications.
        • See reference page 1-42 for specific product information.
        • See reference page 1-51 for installation recommendations.

        Type C5A – box only
        Type C5B – w/galvanized armor
        Type C5C – w/SS armor
        Type C5D – w/wire braid
        Type C5J – w/plain leads

        Electrical Quick Disconnect Plugs: Standard

        Type P1: Quick Disconnect Plugs, One Piece Band

                                                            Type P1M                        Type P1L 
           /Tempco/Data-Assets/01-Band-Images/WebB515.jpg     Type P1M     Type P1L                     
        • Standard Termination Location: Next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)                                                           
        • Plug Electrical Ratings: 2-Pole 3-Wire Grounding
        • Maximum Volts: 250 VAC
        • Maximum Amps: 16A
        • Maximum Temperature: 392°F (200°C)

        Available on any construction or clamping variation. These plug assemblies are highly recommended & should be used whenever possible. The combination of plug & cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

        Type P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference page 1-43, 1-44, and 1-45 for additional product information.

        Type P1K – Cup assembly only
        Type P1L – w/straight plug only
        Type P1M – w/90° plug only
        Type P1N – w/str. plug & galvanized cable
        Type P1O – w/str. plug & SS cable
        Type P1P – w/str. plug & wire braid
        Type P1Q – w/90° plug & galvanized cable
        Type P1R – w/90° plug & SS cable
        Type P1S – w/90° plug & wire braid

        Important: If width is between 1-1/2" and 2", minimum diameter is 5-1/2".

        Type P1: Quick Disconnect Plugs, Two Piece Band

                                                             Type P1M                      Type P1L 
        /Tempco/Data-Assets/01-Band-Images/WebMicaBand_P1_2Pc.jpg       Type P1M     Type P1L                     
        • Standard Termination Location: next to gap; center of width
        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1-1/2" (38.1 mm)                                                           
        • Plug Electrical Ratings: 2-Pole 3-Wire Grounding
        • Maximum Volts: 250 VAC
        • Maximum Amps: 16A
        • Maximum Temperature: 392°F (200°C)

        Available on any construction or clamping variation. These plug assemblies are highly recommended & should be used whenever possible. The combination of plug & cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

        Type P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference page 1-43, 1-44, and 1-45 for additional product information.

        Type P1K – Cup assembly only
        Type P1L – w/straight plug only
        Type P1M – w/90° plug only
        Type P1N – w/str. plug & galvanized cable
        Type P1O – w/str. plug & SS cable
        Type P1P – w/str. plug & wire braid
        Type P1Q – w/90° plug & galvanized cable
        Type P1R – w/90° plug & SS cable
        Type P1S – w/90° plug & wire braid

        Important: If width is between 1-1/2" and 2", minimum diameter is 5-1/2".


        Type P1: Quick Disconnect Plugs, One Piece Expandable Band

                                                            Type P1M                       Type P1L 
          /Tempco/Data-Assets/01-Band-Images/WebMicaBand_P1_1PcX.jpg     Type P1M     Type P1L                     
        • Standard Termination Location: Next to gap; center of width
        • Minimum Inside Diameter: 2-1/2" (63.5 mm)
        • Minimum Width: 1-1/2" (38.1 mm)                                                           
        • Plug Electrical Ratings: 2-Pole 3-Wire Grounding
        • Maximum Volts: 250 VAC
        • Maximum Amps: 16A
        • Maximum Temperature: 572°F (300°C)

        Available on any construction or clamping variation. These plug assemblies are highly recommended & should be used whenever possible. The combination of plug & cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

        Type P1 and P3 assemblies are available with a straight or right-angle plug. Type P2 and P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired, using high temperature lead wires. The standard leads are 10" of armor cable over 12" of flexible leads.

        • See reference page 1-43, 1-44, and 1-45 for additional product information.

        Type P1K – Cup assembly only
        Type P1L – w/straight plug only
        Type P1M – w/90° plug only
        Type P1N – w/str. plug & galvanized cable
        Type P1O – w/str. plug & SS cable
        Type P1P – w/str. plug & wire braid
        Type P1Q – w/90° plug & galvanized cable
        Type P1R – w/90° plug & SS cable
        Type P1S – w/90° plug & wire braid

        Important: If width is between 1-1/2" and 2", minimum diameter is 5-1/2".  If width is greater than 2", the minimum diameter is 2".

        Electrical Quick Disconnect Plugs: Low-Profile

        Type P2: Quick Disconnect Plugs, Low Profile, One Piece Band

                                                                                           Type P2G
                       /Tempco/Data-Assets/01-Band-Images/WebB519.jpg