{"id":6646988374093,"title":"Tempco - Ceramic Insulated Band Heaters","handle":"tempco-ceramic-insulated-band-heaters","description":"\u003cp data-mce-fragment=\"1\"\u003eA helically wound resistance coil made from nickel-chrome wire is precisely strung through specially designed ceramic insulating bricks, forming a flexible heating mat. TEMPCO's style of Ceramic Insulating Bricks offers several benefits including:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eExcellent dielectric strength at high temperatures with high voltages\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAbility to interlock and provide a more rigid structure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAllows for heater widths in smaller increments (1\/8\")\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eReduces the chances of damaging internal coils in transit and handling\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAllows for easier installation of the heater onto the pipe\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThese heaters transmit heat through both conduction \u0026amp; radiation. The element winding is designed to heat the ceramic blocks to the point at which they radiate energy into the barrel as well as conduct energy by being in contact with the barrel - fit is not as critical as in other types of bands.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1400 °F (760 °C) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eNominal Watt Density:\u003c\/strong\u003e 20-45 w\/in\u003csup data-mce-fragment=\"1\"\u003e2 \u003c\/sup\u003e(3-7 w\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Watt Density:\u003c\/strong\u003e 45 w\/in\u003csup data-mce-fragment=\"1\"\u003e2 \u003c\/sup\u003e(7 w\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480V per electrical termination.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eDual Voltage:\u003c\/strong\u003e Available - Depending on heater configuration.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Amperage per Circuit:\u003c\/strong\u003e Lead Wire terminations; 12.5 amp, Screw terminations: 25 amp.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e +10%, - 5%\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e +5%, - 10% \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003ePhysical Size Construction Limitations *\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eSheath Material:\u003c\/strong\u003e Stainless Steel\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eInsulation Material:\u003c\/strong\u003e Ceramic Fiber Blanket; Standard Thickness: 1\/4\" (6.4 mm) \u003cstrong\u003e-\u003c\/strong\u003e Double Thickness: 1\/2\" (12.7 mm). \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 1-62 for additional specifications and reference page 1-74 termination styles and electrical ratings.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOverall Thickness:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 101.955%;\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e \u003cstrong\u003eInsulation Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter Less Than 4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter of 4\" or Greater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter of 4\" or Greater\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\u003cb\u003eStandard\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e5\/8\" (15.9 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDouble\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e11\/16\" (17.5 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e3\/4\" (19.1 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e11\/16\" (17.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eRibcage (Uninsulated)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e11\/32\" (8.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e11\/32\" (8.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Width Increments:\u003c\/strong\u003e 1\/8\" (3.2 mm) - Contact us at (844) 862-7880 for non-standard widths. \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Width (One-Piece \u0026amp; Two-Piece):\u003c\/strong\u003e Dependent upon the ratio of diameter to width. Maximum Width to Diameter Ratio is 3:1 \u003cstrong\u003e-\u003c\/strong\u003e Maximum Width for 5\" or greater ID is 15\".\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e 4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e 1\" (25.4 mm) to 3 1\/2\" (88.9 mm): ±1\/16\" (±1.6 mm) \u003cstrong\u003e-\u003c\/strong\u003e 4\" (101.8 mm) to 6 1\/2\" (165.1 mm): ±1\/8\" (±3.2 mm) \u003cstrong\u003e-\u003c\/strong\u003e Over 6 1\/2\" (165.1 mm): ±1\/4\" (6.4 mm). \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e One-Piece; 2\" (50.8 mm) \u003cstrong\u003e-\u003c\/strong\u003e Two-Piece; 4\" (101.6 mm) \u003cstrong\u003e-\u003c\/strong\u003e Reverse Band; 5 1\/2\" (139.7 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eNominal Gap:\u003c\/strong\u003e 3\/8\" (9.5 mm) - If a larger gap is required for probes or thermocouples, then please specify when ordering. \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-63, 1-64, and 1-65 for Standard (Non-Stock) Ceramic Band specifications\/ordering information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003eNote: If tighter tolerances are required, then please contact us at (844) 862-7880 for assistance.\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003eOne Piece Band\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE527.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE527.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe One-Piece Ceramic Band Heater is the basic design most often specified by OEMs and processors. It is available with all types of insulation, construction styles, clamping or termination variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 21\" (533.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cem\u003e \u003cstrong data-mce-fragment=\"1\"\u003eClamping Options (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4\u003eType B – Built-In Bracket (Standard) - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1\/4-20. It is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType S – Built-In Bracket with Spring-Loaded Screw - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4 style=\"text-align: left;\"\u003eType L – Latch and Trunnion - One Piece Band\u003cbr\u003e\u003cem\u003e\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe spring-loaded Latch and Trunnion clamping system is ideal for bands over 12\" in diameter to absorb thermal expansion and facilitate installation on large bands.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType F – Bent-Up Flange (Ears) - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eShell Overlap - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1 1\/2\" (38.1 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Hole: \u003c\/strong\u003e3\/4\" (19.1 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType T2 – Screw Terminals - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2\" in width unless otherwise specified. 10-32 post terminals are standard.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eNot available for Reverse Construction.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType T3 – Screw Terminals - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE523.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE523.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType L1: Straight Lead Wires – One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE517.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE517.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10\" long.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eopposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType W1: Abrasion Resistant Straight Wire Braid Leads – One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE518.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE518.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStraight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: \u003cspan data-mce-fragment=\"1\"\u003eStainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType W2M: Right-Angle Wire Braid Leads, 90\u003cstrong\u003e° to Heater - One Piece Band\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE544.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE544.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eNote: If longer leads are required, specify when ordering.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e__________\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE543.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE543.jpg\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003ch4\u003eType R1: Abrasion Resistant Straight Armor Cable - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE520.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE520.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStraight Armor Cable is available with all types of insulation, construction styles, and clamping variations. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Galvanized Steel Armor Cable\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Armor Cable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: \u003cspan data-mce-fragment=\"1\"\u003eStainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStrain Relief (One Piece Band)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eType S1:\u003cspan\u003e Lead Wire Spring Strain Relief - One Piece Band\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE519.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5\/8\" long. The flexible standard leads are 10\" long with 2-1\/2\" of fiberglass sleeving.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Plain Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Wire Braided Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Terminal Boxes (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType C2 – Standard Terminal Box - One-Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE530.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE530.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC2A\u003c\/strong\u003e\u003c\/span\u003e – Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2B\u003c\/strong\u003e\u003c\/span\u003e – with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2C\u003c\/strong\u003e\u003c\/span\u003e – with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2D\u003c\/strong\u003e\u003c\/span\u003e – with wire braid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 1-1\/2\"W × 2-1\/2\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 2-1\/8\"W × 2-1\/8\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType C5: Low-Profile Terminal Box - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE534.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE534.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/h4\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC5A\u003c\/strong\u003e\u003c\/span\u003e – Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5B\u003c\/strong\u003e\u003c\/span\u003e – with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5C\u003c\/strong\u003e\u003c\/span\u003e – with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5D\u003c\/strong\u003e\u003c\/span\u003e – with wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5J\u003c\/strong\u003e\u003c\/span\u003e – box with lead wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 1-1\/4\"W × 3\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 2-1\/4\"W × 2\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003cem\u003e\u003cbr data-mce-fragment=\"1\"\u003e2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Quick Disconnect Plugs (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P1: Quick Disconnect Plugs - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebF519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebF519.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm) depending on termination orientation\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P2: Quick Disconnect Plugs, Low-Profile - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE515.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE515.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Type P2 plug assemblies have a lower profile and are available with a straight plug only.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\\\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\/\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVertical \u0026amp; Horizontal Quick Disconnect Plugs (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P3: Din 49458 A\/B Quick Disconnect Plugs, Vertical - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE501.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE501.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP3A \u003c\/strong\u003e\u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3B \u003c\/strong\u003e\u003c\/span\u003e– Box assembly w\/straight plug\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3C \u003c\/strong\u003e\u003c\/span\u003e– Box assembly w\/right-angle plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eType P4: Din 49458 A\/B Quick Disconnect Plugs, Horizontal - One Piece Band\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebF521.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebF521.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eOpposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP4A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP4B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\"\u003eTwo Piece Band\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE528.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE528.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Two-Piece Ceramic Band Heater is commonly used on sizes larger than 21\" diameter or when it would be inconvenient to use a one-piece heater. It is available with all types of insulation, construction styles, clamping or termination variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e 1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 44\" (1118 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Larger sizes are manufactured in multiple sections. Watts and volts are specified per each section when ordering.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eClamping Options (Two-Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType B – Built-In Bracket (Standard) - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1\/4-20. It is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003cem\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003eType S – Built-In Bracket with Spring-Loaded Screw - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003eType L – Latch and Trunnion - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe spring-loaded Latch and Trunnion clamping system is ideal for bands over 12\" in diameter to absorb thermal expansion and facilitate installation on large bands.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType F - Bent-Up Flange (Ears) - Two Piece Band\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003eThe Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2.5\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eShell Overlap - Two-Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Hole:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType T2 – Screw Terminals - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2\" in width unless otherwise specified. 10-32 post terminals are standard.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cb\u003e\u003ci\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3 – Screw Terminals - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T3_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eType T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_L1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_L1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eType L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10\" long.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003ci\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/i\u003e\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion Resistant Straight Wire Braid Leads - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStraight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90\u003cstrong data-mce-fragment=\"1\"\u003e° to Heater - Two Piece Band\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W2M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W2M_2Pc.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: If longer leads are required, specify when ordering.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W5M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W5M_2Pc.jpg\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: If longer leads are required, specify when ordering.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Abrasion Resistant Right-Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eRight-Angle Armor Cable is available with all types of insulation, construction styles, and clamping variations. It is used where space is limited and abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR2A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Galvanized Steel Armor Cable\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR2B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Armor Cable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Stainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStrain Relief (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType S1: Lead Wire Spring Strain Relief - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5\/8\" long. The flexible standard leads are 10\" long with 2-1\/2\" of fiberglass sleeving.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1A\u003c\/strong\u003e\u003c\/span\u003e – Plain Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Wire Braided Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Terminal Boxes (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType C2 – Standard Terminal Box - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC2A \u003c\/strong\u003e\u003c\/span\u003e– Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2B \u003c\/strong\u003e\u003c\/span\u003e– with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2C \u003c\/strong\u003e\u003c\/span\u003e– with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2D \u003c\/strong\u003e\u003c\/span\u003e– with wire braid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 1-1\/2\"W × 2-1\/2\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 2-1\/8\"W × 2-1\/8\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType C5 – Low-Profile Terminal Box - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC5A \u003c\/strong\u003e\u003c\/span\u003e– Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5B \u003c\/strong\u003e\u003c\/span\u003e– with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5C \u003c\/strong\u003e\u003c\/span\u003e– with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5D \u003c\/strong\u003e\u003c\/span\u003e– with wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5J \u003c\/strong\u003e\u003c\/span\u003e– box with lead wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 1-1\/4\"W × 3\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 2-1\/4\"W × 2\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003cem\u003e\u003cbr data-mce-fragment=\"1\"\u003e2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Quick Disconnect Plugs (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P1: Quick Disconnect Plugs - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm) depending on termination orientation\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P2: Quick Disconnect Plugs, Low-Profile - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Type P2 plug assemblies have a lower profile and are available with a straight plug only.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVertical \u0026amp; Horizontal Quick Disconnect Plugs (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P3: Din 49458 A\/B Quick Disconnect Plugs, Vertical - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P3_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP3A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/right-angle plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P4: Din 49458 A\/B Quick Disconnect Plugs, Horizontal - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P4_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eCenter of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP4A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP4B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cem\u003e\u003c\/em\u003e\u003cem\u003eReverse Band\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE541.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE541.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eReverse Ceramic Band Heaters are intended for the outer surface of the band to heat the inner surface of a cylinder. These heaters use the same built-in insulation as normal ceramic bands and therefor can either reduce the power needed to heat an application to the desired temperature or offer some thermal protection to anything else that might also be inside the cylinder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe specially designed internal brackets exert outward pressure to ensure good contact with the application surface. To aid in holding the internal components together during installation, reverse ceramic bands are supplied with a perforated stainless steel outer liner.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe outer diameter is the distinguishing characteristic and should match the inner diameter of the cylinder to be heated.  \u003c\/span\u003e\u003cspan\u003eIf airflow is needed for cooling, Tempco’s Type R Uninsulated Ceramic Band with a perforated sheath is also available. This is also the same robust construction that can reach higher temperatures than other heater bands.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 5-1\/2\" \u003cem\u003e(139.7 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e 1\" \u003cem\u003e(25.4 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 44\" \u003cem\u003e(1118 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e 4\" \u003cem\u003e(101.6 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Options:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOptional Double Insulation (D): 1\/2\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE533.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE533.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard built-In ceramic fiber insulation 1\/4\" thick on all Ceramic Bands; will reduce power consumption by 25 to 30 percent and lower external temperatures (when compared to uninsulated band heaters).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOptional built-in ceramic fiber insulation 1\/2\" thick is available; for situations requiring additional insulation for lower external temperatures and increased electrical energy savings. This will decrease power consumption by 35 to 37 percent (when compared to uninsulated band heaters).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Not available for Reverse Construction.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R: Uninsulated Ceramic Band Heaters\u003c\/h4\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg?Small\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eType R Construction is an uninsulated ceramic band heater with a perforated Stainless Steel outer shell for more efficient cooling.  It is typically used in multiple quantities with forced air cooling systems such as Tempco's Cool TO-THE Touch Shroud Systems (see Type RCC below).\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Watt Density\u003c\/strong\u003e: 50 W\/in2 (8 W\/cm2)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e: 900°F (482°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Width Increments:\u003c\/strong\u003e 1\/8\" 3.2 cm\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e depends on ratio of diameter to width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Gap:\u003c\/strong\u003e 3\/8\" ±1\/8\" (9.5 ±3.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eResistance tolerance:\u003c\/strong\u003e +10%, –5%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWattage tolerance:\u003c\/strong\u003e +5%, –10%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480 single or 3-phase (when applicable)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amperage:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e 25 Amps per circuit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eLead Wire:\u003c\/strong\u003e 10 Amps per circuit\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType RCC: (Ribcage) Heating Mounting Configuration\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg?Small\"\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis system was developed to reduce the cost and weight of typical shroud systems for the heating and cooling of high temperature extrusion processes.  Type RCC (Rib Cage) Air Cooled Systems use multiple Type R Ceramic Band Heaters under one shroud.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eThese low mass, non-thermally insulated ceramic band heaters work in tandem with a highly efficient stainless steel sheet metal shroud and are typically arranged with spaces between the heaters to enhance the cooling of the barrel when external heat is no longer required.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eForced air blowers are used for cooling. The ambient airflow enters the shroud, circulates around the ceramic heater and barrel, removes the heat from the heater and the process and exits the shroud opposite the entrance port.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eThe Cool TO-THE Touch dual layer shroud uses an inner stainless steel solid layer thermally isolated from the heater, providing a path for the forced cooling air. An outer Stainless Steel perforated layer provides optimal venting and heat dissipation while providing personnel safety.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eIgloo\u003cspan\u003e® Ceramic Terminal Covers\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cspan data-mce-fragment=\"1\"\u003eType C6: Double Port In-Line\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Type C6: Double Port In-Line\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB217.jpg?Medium\" width=\"123\" height=\"123\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cspan\u003eType C7: Double Port 90°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"Type C7: Double Port 90°\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB218.jpg?Medium\" width=\"121\" height=\"121\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cspan\u003eType C8: Single Port 90°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"Type C8: Single Port 90°\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB219.jpg?Medium\" width=\"121\" height=\"121\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIgloo™ Ceramic Terminal Covers consist of two individual ceramic parts. They are available with all types of insulation, construction styles, and clamping variations. Unlike conventional ceramic caps, Igloo fully insulates any standard #10 terminal lugs used for electrical hook-ups.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLimitations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne-Piece Band with Type T2 or Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eTwo-Piece Band with Type T2 or Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diamter:\u003c\/strong\u003e 4\" (101.6 mm)  \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band with Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diamter:\u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThree types of Igloo™ bases are available:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e \u003c\/span\u003e— Double Port In-Line P\/N CER-101-104\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e— Double Port 90° P\/N CER-101-106\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e— Single Port P\/N CER-101-107\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Igloo™ caps are available in the following screw terminal size:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e10-32 — P\/N CER-102-101\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThree-Phase\u003c\/h4\u003e\n\u003cp\u003eOn very high wattage band heaters it would be advantageous to set up the wiring three-phase to reduce the current load across a single conductor. Three-phase wiring is available with all types of insulation, construction styles, and clamping variations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eDual Voltage\u003c\/h4\u003e\n\u003cp\u003eBand heaters can be designed using 3-wire series\/parallel circuits for dual voltage applications. Whether the heater is run on the high or low voltage, the wattage will be the same. Dual Voltage wiring is available with all types of insulation, construction styles, or clamping variations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSingle-Phase\/Three-Phase\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCeramic Band Heaters can be designed with multiple circuits to operate single or three-phase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eElectrical Plugs\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eIndustry standard NEMA twist lock electrical connectors are available. The plugs can be attached to fiberglass leads, armor cable or wire braid. Electrical Plugs can be added to any termination variation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTerminal Lugs\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eVarious types of crimp terminals can be attached to the heater leads to make wiring into applications quick and easy. High temperature [1200°F (649°C)] ring terminals and nylon or PVC insulated terminals are available. Spade, ring, and right-angle or straight quick disconnect type terminals can be attached to the leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHigh Temperature Lead Wire\u003c\/h4\u003e\n\u003cp\u003eWhen required, high temperature lead wire can be used. The wire is insulated with mica tapes over the stranded nickel conductors and then treated fiberglass over-braid.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 450°C (842°F)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eGround Terminal or Lead\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor those applications requiring a separate ground terminal or lead attached to the heater sheath. A Ground Terminal or Lead is available on any construction or termination variation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOversize Gap\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe nominal gap is 3\/8\". If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe nominal gap is 3\/8\".  If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCommon Applications:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e","published_at":"2021-08-30T11:24:30-04:00","created_at":"2021-08-25T16:43:35-04:00","vendor":"Tempco","type":"Replacement Parts","tags":["Electronics","Food \u0026 Beverage","Heaters","Manufacturing","Medical \u0026 Pharmaceutical Production","Plastic Fabrication","Process Heat","Replacement Parts","Tempco"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39445399765069,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"BCH00017","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Tempco - Ceramic Insulated Band Heaters","public_title":null,"options":["Default Title"],"price":0,"weight":2268,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-1.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-2.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-3.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-4.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-5.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-6.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-7.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-8.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-9.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-10.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-11.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-12.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-13.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-14.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-15.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-16.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-17.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-18.png?v=1629987979","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-19.png?v=1629988049"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters.png?v=1629987979","options":["Title"],"media":[{"alt":null,"id":20903818133581,"position":1,"preview_image":{"aspect_ratio":0.837,"height":631,"width":528,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters.png?v=1629987979"},"aspect_ratio":0.837,"height":631,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters.png?v=1629987979","width":528},{"alt":null,"id":20903820820557,"position":2,"preview_image":{"aspect_ratio":0.8,"height":869,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-1.png?v=1629987979"},"aspect_ratio":0.8,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-1.png?v=1629987979","width":695},{"alt":null,"id":20903820853325,"position":3,"preview_image":{"aspect_ratio":0.803,"height":865,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-2.png?v=1629987979"},"aspect_ratio":0.803,"height":865,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-2.png?v=1629987979","width":695},{"alt":null,"id":20903820886093,"position":4,"preview_image":{"aspect_ratio":0.802,"height":868,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-3.png?v=1629987979"},"aspect_ratio":0.802,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-3.png?v=1629987979","width":696},{"alt":null,"id":20903820918861,"position":5,"preview_image":{"aspect_ratio":0.803,"height":868,"width":697,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-4.png?v=1629987979"},"aspect_ratio":0.803,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-4.png?v=1629987979","width":697},{"alt":null,"id":20903820951629,"position":6,"preview_image":{"aspect_ratio":0.802,"height":867,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-5.png?v=1629987979"},"aspect_ratio":0.802,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-5.png?v=1629987979","width":695},{"alt":null,"id":20903820984397,"position":7,"preview_image":{"aspect_ratio":0.8,"height":870,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-6.png?v=1629987979"},"aspect_ratio":0.8,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-6.png?v=1629987979","width":696},{"alt":null,"id":20903821017165,"position":8,"preview_image":{"aspect_ratio":0.805,"height":867,"width":698,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-7.png?v=1629987979"},"aspect_ratio":0.805,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-7.png?v=1629987979","width":698},{"alt":null,"id":20903821049933,"position":9,"preview_image":{"aspect_ratio":0.803,"height":867,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-8.png?v=1629987979"},"aspect_ratio":0.803,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-8.png?v=1629987979","width":696},{"alt":null,"id":20903821082701,"position":10,"preview_image":{"aspect_ratio":0.804,"height":866,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-9.png?v=1629987979"},"aspect_ratio":0.804,"height":866,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-9.png?v=1629987979","width":696},{"alt":null,"id":20903821115469,"position":11,"preview_image":{"aspect_ratio":0.8,"height":868,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-10.png?v=1629987979"},"aspect_ratio":0.8,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-10.png?v=1629987979","width":694},{"alt":null,"id":20903821148237,"position":12,"preview_image":{"aspect_ratio":0.802,"height":867,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-11.png?v=1629987979"},"aspect_ratio":0.802,"height":867,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-11.png?v=1629987979","width":695},{"alt":null,"id":20903821181005,"position":13,"preview_image":{"aspect_ratio":0.804,"height":866,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-12.png?v=1629987979"},"aspect_ratio":0.804,"height":866,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-12.png?v=1629987979","width":696},{"alt":null,"id":20903821213773,"position":14,"preview_image":{"aspect_ratio":0.797,"height":872,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-13.png?v=1629987979"},"aspect_ratio":0.797,"height":872,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-13.png?v=1629987979","width":695},{"alt":null,"id":20903821246541,"position":15,"preview_image":{"aspect_ratio":0.8,"height":868,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-14.png?v=1629987979"},"aspect_ratio":0.8,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-14.png?v=1629987979","width":694},{"alt":null,"id":20903821279309,"position":16,"preview_image":{"aspect_ratio":0.799,"height":870,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-15.png?v=1629987979"},"aspect_ratio":0.799,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-15.png?v=1629987979","width":695},{"alt":null,"id":20903821312077,"position":17,"preview_image":{"aspect_ratio":0.797,"height":871,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-16.png?v=1629987979"},"aspect_ratio":0.797,"height":871,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-16.png?v=1629987979","width":694},{"alt":null,"id":20903821344845,"position":18,"preview_image":{"aspect_ratio":0.801,"height":870,"width":697,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-17.png?v=1629987979"},"aspect_ratio":0.801,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-17.png?v=1629987979","width":697},{"alt":null,"id":20903821377613,"position":19,"preview_image":{"aspect_ratio":0.799,"height":870,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-18.png?v=1629987979"},"aspect_ratio":0.799,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-18.png?v=1629987979","width":695},{"alt":null,"id":20903828160589,"position":20,"preview_image":{"aspect_ratio":0.797,"height":871,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-19.png?v=1629988049"},"aspect_ratio":0.797,"height":871,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoCeramicInsulatedBandHeaters-19.png?v=1629988049","width":694}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-mce-fragment=\"1\"\u003eA helically wound resistance coil made from nickel-chrome wire is precisely strung through specially designed ceramic insulating bricks, forming a flexible heating mat. TEMPCO's style of Ceramic Insulating Bricks offers several benefits including:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eExcellent dielectric strength at high temperatures with high voltages\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAbility to interlock and provide a more rigid structure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAllows for heater widths in smaller increments (1\/8\")\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eReduces the chances of damaging internal coils in transit and handling\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAllows for easier installation of the heater onto the pipe\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThese heaters transmit heat through both conduction \u0026amp; radiation. The element winding is designed to heat the ceramic blocks to the point at which they radiate energy into the barrel as well as conduct energy by being in contact with the barrel - fit is not as critical as in other types of bands.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1400 °F (760 °C) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eNominal Watt Density:\u003c\/strong\u003e 20-45 w\/in\u003csup data-mce-fragment=\"1\"\u003e2 \u003c\/sup\u003e(3-7 w\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Watt Density:\u003c\/strong\u003e 45 w\/in\u003csup data-mce-fragment=\"1\"\u003e2 \u003c\/sup\u003e(7 w\/cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480V per electrical termination.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eDual Voltage:\u003c\/strong\u003e Available - Depending on heater configuration.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Amperage per Circuit:\u003c\/strong\u003e Lead Wire terminations; 12.5 amp, Screw terminations: 25 amp.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e +10%, - 5%\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e +5%, - 10% \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003ePhysical Size Construction Limitations *\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eSheath Material:\u003c\/strong\u003e Stainless Steel\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eInsulation Material:\u003c\/strong\u003e Ceramic Fiber Blanket; Standard Thickness: 1\/4\" (6.4 mm) \u003cstrong\u003e-\u003c\/strong\u003e Double Thickness: 1\/2\" (12.7 mm). \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 1-62 for additional specifications and reference page 1-74 termination styles and electrical ratings.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOverall Thickness:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 101.955%;\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e \u003cstrong\u003eInsulation Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter Less Than 4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter of 4\" or Greater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDiameter of 4\" or Greater\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\u003cb\u003eStandard\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e5\/8\" (15.9 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDouble\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e11\/16\" (17.5 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e3\/4\" (19.1 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e11\/16\" (17.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center; width: 18%;\" data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eRibcage (Uninsulated)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e11\/32\" (8.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16%;\" data-mce-fragment=\"1\"\u003e1\/2\" (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 14.5825%;\" data-mce-fragment=\"1\"\u003e11\/32\" (8.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Width Increments:\u003c\/strong\u003e 1\/8\" (3.2 mm) - Contact us at (844) 862-7880 for non-standard widths. \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Width (One-Piece \u0026amp; Two-Piece):\u003c\/strong\u003e Dependent upon the ratio of diameter to width. Maximum Width to Diameter Ratio is 3:1 \u003cstrong\u003e-\u003c\/strong\u003e Maximum Width for 5\" or greater ID is 15\".\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e 4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e 1\" (25.4 mm) to 3 1\/2\" (88.9 mm): ±1\/16\" (±1.6 mm) \u003cstrong\u003e-\u003c\/strong\u003e 4\" (101.8 mm) to 6 1\/2\" (165.1 mm): ±1\/8\" (±3.2 mm) \u003cstrong\u003e-\u003c\/strong\u003e Over 6 1\/2\" (165.1 mm): ±1\/4\" (6.4 mm). \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e One-Piece; 2\" (50.8 mm) \u003cstrong\u003e-\u003c\/strong\u003e Two-Piece; 4\" (101.6 mm) \u003cstrong\u003e-\u003c\/strong\u003e Reverse Band; 5 1\/2\" (139.7 mm).\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eNominal Gap:\u003c\/strong\u003e 3\/8\" (9.5 mm) - If a larger gap is required for probes or thermocouples, then please specify when ordering. \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-63, 1-64, and 1-65 for Standard (Non-Stock) Ceramic Band specifications\/ordering information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003eNote: If tighter tolerances are required, then please contact us at (844) 862-7880 for assistance.\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\"\u003eOne Piece Band\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE527.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE527.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe One-Piece Ceramic Band Heater is the basic design most often specified by OEMs and processors. It is available with all types of insulation, construction styles, clamping or termination variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 21\" (533.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cem\u003e \u003cstrong data-mce-fragment=\"1\"\u003eClamping Options (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4\u003eType B – Built-In Bracket (Standard) - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1\/4-20. It is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType S – Built-In Bracket with Spring-Loaded Screw - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4 style=\"text-align: left;\"\u003eType L – Latch and Trunnion - One Piece Band\u003cbr\u003e\u003cem\u003e\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe spring-loaded Latch and Trunnion clamping system is ideal for bands over 12\" in diameter to absorb thermal expansion and facilitate installation on large bands.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType F – Bent-Up Flange (Ears) - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eShell Overlap - One Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e3\" (76.2 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1 1\/2\" (38.1 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Hole: \u003c\/strong\u003e3\/4\" (19.1 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType T2 – Screw Terminals - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2\" in width unless otherwise specified. 10-32 post terminals are standard.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eNot available for Reverse Construction.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType T3 – Screw Terminals - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE523.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE523.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType L1: Straight Lead Wires – One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE517.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE517.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10\" long.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eopposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType W1: Abrasion Resistant Straight Wire Braid Leads – One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE518.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE518.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStraight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: \u003cspan data-mce-fragment=\"1\"\u003eStainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch4\u003eType W2M: Right-Angle Wire Braid Leads, 90\u003cstrong\u003e° to Heater - One Piece Band\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE544.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE544.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eNote: If longer leads are required, specify when ordering.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e__________\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE543.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE543.jpg\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003ch4\u003eType R1: Abrasion Resistant Straight Armor Cable - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE520.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE520.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eStraight Armor Cable is available with all types of insulation, construction styles, and clamping variations. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Galvanized Steel Armor Cable\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Armor Cable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eReverse Band: \u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: \u003cspan data-mce-fragment=\"1\"\u003eStainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e__________\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStrain Relief (One Piece Band)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eType S1:\u003cspan\u003e Lead Wire Spring Strain Relief - One Piece Band\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE519.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5\/8\" long. The flexible standard leads are 10\" long with 2-1\/2\" of fiberglass sleeving.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Plain Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Wire Braided Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Terminal Boxes (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType C2 – Standard Terminal Box - One-Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE530.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE530.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC2A\u003c\/strong\u003e\u003c\/span\u003e – Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2B\u003c\/strong\u003e\u003c\/span\u003e – with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2C\u003c\/strong\u003e\u003c\/span\u003e – with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2D\u003c\/strong\u003e\u003c\/span\u003e – with wire braid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 1-1\/2\"W × 2-1\/2\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 2-1\/8\"W × 2-1\/8\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType C5: Low-Profile Terminal Box - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE534.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE534.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/h4\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC5A\u003c\/strong\u003e\u003c\/span\u003e – Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5B\u003c\/strong\u003e\u003c\/span\u003e – with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5C\u003c\/strong\u003e\u003c\/span\u003e – with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5D\u003c\/strong\u003e\u003c\/span\u003e – with wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5J\u003c\/strong\u003e\u003c\/span\u003e – box with lead wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 1-1\/4\"W × 3\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 2-1\/4\"W × 2\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003cem\u003e\u003cbr data-mce-fragment=\"1\"\u003e2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Quick Disconnect Plugs (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P1: Quick Disconnect Plugs - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebF519.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebF519.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm) depending on termination orientation\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P2: Quick Disconnect Plugs, Low-Profile - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE515.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE515.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Type P2 plug assemblies have a lower profile and are available with a straight plug only.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\\\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\/\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVertical \u0026amp; Horizontal Quick Disconnect Plugs (One Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P3: Din 49458 A\/B Quick Disconnect Plugs, Vertical - One Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE501.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE501.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature: \u003c\/strong\u003e392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP3A \u003c\/strong\u003e\u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3B \u003c\/strong\u003e\u003c\/span\u003e– Box assembly w\/straight plug\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3C \u003c\/strong\u003e\u003c\/span\u003e– Box assembly w\/right-angle plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eType P4: Din 49458 A\/B Quick Disconnect Plugs, Horizontal - One Piece Band\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebF521.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebF521.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eOpposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP4A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP4B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\"\u003eTwo Piece Band\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE528.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE528.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Two-Piece Ceramic Band Heater is commonly used on sizes larger than 21\" diameter or when it would be inconvenient to use a one-piece heater. It is available with all types of insulation, construction styles, clamping or termination variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e 1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 44\" (1118 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Larger sizes are manufactured in multiple sections. Watts and volts are specified per each section when ordering.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eClamping Options (Two-Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType B – Built-In Bracket (Standard) - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1\/4-20. It is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003cem\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4\u003eType S – Built-In Bracket with Spring-Loaded Screw - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003eType L – Latch and Trunnion - Two Piece Band\u003c\/h4\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eThe spring-loaded Latch and Trunnion clamping system is ideal for bands over 12\" in diameter to absorb thermal expansion and facilitate installation on large bands.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e4\" (101.6 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e \u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2\" (50.8 mm) \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType F - Bent-Up Flange (Ears) - Two Piece Band\u003c\/h4\u003e\n\u003ch4\u003e\u003cspan\u003eThe Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cem\u003eLimitations\u003c\/em\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e2.5\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eShell Overlap - Two-Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Hole:\u003c\/strong\u003e 3\/4\" (19.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType T2 – Screw Terminals - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eType T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2\" in width unless otherwise specified. 10-32 post terminals are standard.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cb\u003e\u003ci\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3 – Screw Terminals - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_T3_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eType T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Straight Lead Wires - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_L1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_L1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eType L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10\" long.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003ci\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/i\u003e\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion Resistant Straight Wire Braid Leads - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStraight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2M: Right-Angle Wire Braid Leads, 90\u003cstrong data-mce-fragment=\"1\"\u003e° to Heater - Two Piece Band\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W2M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W2M_2Pc.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: If longer leads are required, specify when ordering.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5M: Right-Angle Wire Braid Leads, Parallel to Heater - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W5M_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_W5M_2Pc.jpg\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10\" of wire braid over 12\" of flexible leads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Opposite the gap; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: If longer leads are required, specify when ordering.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e__________\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2: Abrasion Resistant Right-Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_R2_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eRight-Angle Armor Cable is available with all types of insulation, construction styles, and clamping variations. It is used where space is limited and abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10\" of armor cable over 12\" of flexible leads.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR2A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Galvanized Steel Armor Cable\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eR2B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Armor Cable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-68 and 1-69 for additional electrical termination information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Stainless steel construction may be required for widths of 7\/8\" (22.2 mm) to 1-5\/8\" (41.3 mm).\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStrain Relief (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType S1: Lead Wire Spring Strain Relief - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_S1_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eA strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5\/8\" long. The flexible standard leads are 10\" long with 2-1\/2\" of fiberglass sleeving.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1A\u003c\/strong\u003e\u003c\/span\u003e – Plain Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Stainless Steel Wire Braided Leads and Strain Relief Spring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Terminal Boxes (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType C2 – Standard Terminal Box - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_C2_2Pc.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC2A \u003c\/strong\u003e\u003c\/span\u003e– Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2B \u003c\/strong\u003e\u003c\/span\u003e– with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2C \u003c\/strong\u003e\u003c\/span\u003e– with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC2D \u003c\/strong\u003e\u003c\/span\u003e– with wire braid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 1-1\/2\"W × 2-1\/2\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1-1\/2\"H × 2-1\/8\"W × 2-1\/8\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType C5 – Low-Profile Terminal Box - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003eTerminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.\u003c\/p\u003e\n\u003cp\u003eThe Heavy Duty Terminal Boxes have a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7\/8\". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eC5A \u003c\/strong\u003e\u003c\/span\u003e– Box only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5B \u003c\/strong\u003e\u003c\/span\u003e– with galvanized armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5C \u003c\/strong\u003e\u003c\/span\u003e– with stainless steel armor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5D \u003c\/strong\u003e\u003c\/span\u003e– with wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eC5J \u003c\/strong\u003e\u003c\/span\u003e– box with lead wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 1-1\/4\"W × 3\"L for bands 1-1\/2\" to 2\" wide\u003cbr\u003e\u003cstrong\u003eBox Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\"H × 2-1\/4\"W × 2\"L for bands greater than 2\" wide\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e​​​​​​​\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  15\" (381 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Heater dimensions will determine terminal configuration.\u003c\/em\u003e\u003cem\u003e\u003cbr data-mce-fragment=\"1\"\u003e2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard \u0026amp; Low-Profile Quick Disconnect Plugs (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P1: Quick Disconnect Plugs - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P1_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P1_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm) depending on termination orientation\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e – Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e – w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e – w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P2: Quick Disconnect Plugs, Low-Profile - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P2_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P2_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Type P2 plug assemblies have a lower profile and are available with a straight plug only.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP1K\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Cup Assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1L\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1M\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1N\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1O\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1P\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/straight plug \u0026amp; wire braid\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1Q\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; galvanized armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1R\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; stainless steel armor cable\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP1S\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– w\/90° plug \u0026amp; wire braid\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVertical \u0026amp; Horizontal Quick Disconnect Plugs (Two Piece Band)\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003eType P3: Din 49458 A\/B Quick Disconnect Plugs, Vertical - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P3_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P3_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e Center of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP3A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP3C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/right-angle plug\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4\u003eType P4: Din 49458 A\/B Quick Disconnect Plugs, Horizontal - Two Piece Band\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P4_2Pc.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebCrmcBand_P4_2Pc.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eQuick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.\u003c\/p\u003e\n\u003cp\u003eType P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location: \u003c\/strong\u003eCenter of each half; Center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 4\" (101.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band:\u003c\/strong\u003e  Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug Electrical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e2-Pole 3-Wire Grounding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250 VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 16A\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eP4A\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly only\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eP4B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e– Box assembly w\/straight plug\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003c\/h3\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cem\u003e\u003c\/em\u003e\u003cem\u003eReverse Band\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE541.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE541.jpg?Small\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eReverse Ceramic Band Heaters are intended for the outer surface of the band to heat the inner surface of a cylinder. These heaters use the same built-in insulation as normal ceramic bands and therefor can either reduce the power needed to heat an application to the desired temperature or offer some thermal protection to anything else that might also be inside the cylinder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Insulation (S): 1\/4\"\u003c\/strong\u003e\u003cbr\u003eBuilt-In ceramic fiber insulation ¼\" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe specially designed internal brackets exert outward pressure to ensure good contact with the application surface. To aid in holding the internal components together during installation, reverse ceramic bands are supplied with a perforated stainless steel outer liner.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe outer diameter is the distinguishing characteristic and should match the inner diameter of the cylinder to be heated.  \u003c\/span\u003e\u003cspan\u003eIf airflow is needed for cooling, Tempco’s Type R Uninsulated Ceramic Band with a perforated sheath is also available. This is also the same robust construction that can reach higher temperatures than other heater bands.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 5-1\/2\" \u003cem\u003e(139.7 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e 1\" \u003cem\u003e(25.4 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inside Diameter:\u003c\/strong\u003e 44\" \u003cem\u003e(1118 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e 4\" \u003cem\u003e(101.6 mm)\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference pages 1-66 and 1-67 for additional construction information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cem\u003e________________________________________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Options:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOptional Double Insulation (D): 1\/2\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE533.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE533.jpg?Small\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard built-In ceramic fiber insulation 1\/4\" thick on all Ceramic Bands; will reduce power consumption by 25 to 30 percent and lower external temperatures (when compared to uninsulated band heaters).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOptional built-in ceramic fiber insulation 1\/2\" thick is available; for situations requiring additional insulation for lower external temperatures and increased electrical energy savings. This will decrease power consumption by 35 to 37 percent (when compared to uninsulated band heaters).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Not available for Reverse Construction.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R: Uninsulated Ceramic Band Heaters\u003c\/h4\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebE531.jpg?Small\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eType R Construction is an uninsulated ceramic band heater with a perforated Stainless Steel outer shell for more efficient cooling.  It is typically used in multiple quantities with forced air cooling systems such as Tempco's Cool TO-THE Touch Shroud Systems (see Type RCC below).\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Watt Density\u003c\/strong\u003e: 50 W\/in2 (8 W\/cm2)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e: 900°F (482°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Ratings\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Width Increments:\u003c\/strong\u003e 1\/8\" 3.2 cm\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Width:\u003c\/strong\u003e depends on ratio of diameter to width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Gap:\u003c\/strong\u003e 3\/8\" ±1\/8\" (9.5 ±3.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eResistance tolerance:\u003c\/strong\u003e +10%, –5%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWattage tolerance:\u003c\/strong\u003e +5%, –10%\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 480 single or 3-phase (when applicable)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amperage:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e 25 Amps per circuit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eLead Wire:\u003c\/strong\u003e 10 Amps per circuit\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType RCC: (Ribcage) Heating Mounting Configuration\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebA604.jpg?Small\"\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis system was developed to reduce the cost and weight of typical shroud systems for the heating and cooling of high temperature extrusion processes.  Type RCC (Rib Cage) Air Cooled Systems use multiple Type R Ceramic Band Heaters under one shroud.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eThese low mass, non-thermally insulated ceramic band heaters work in tandem with a highly efficient stainless steel sheet metal shroud and are typically arranged with spaces between the heaters to enhance the cooling of the barrel when external heat is no longer required.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eForced air blowers are used for cooling. The ambient airflow enters the shroud, circulates around the ceramic heater and barrel, removes the heat from the heater and the process and exits the shroud opposite the entrance port.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eThe Cool TO-THE Touch dual layer shroud uses an inner stainless steel solid layer thermally isolated from the heater, providing a path for the forced cooling air. An outer Stainless Steel perforated layer provides optimal venting and heat dissipation while providing personnel safety.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eIgloo\u003cspan\u003e® Ceramic Terminal Covers\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cspan data-mce-fragment=\"1\"\u003eType C6: Double Port In-Line\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Type C6: Double Port In-Line\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB217.jpg?Medium\" width=\"123\" height=\"123\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cspan\u003eType C7: Double Port 90°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"Type C7: Double Port 90°\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB218.jpg?Medium\" width=\"121\" height=\"121\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cspan\u003eType C8: Single Port 90°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"Type C8: Single Port 90°\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB219.jpg?Medium\" width=\"121\" height=\"121\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIgloo™ Ceramic Terminal Covers consist of two individual ceramic parts. They are available with all types of insulation, construction styles, and clamping variations. Unlike conventional ceramic caps, Igloo fully insulates any standard #10 terminal lugs used for electrical hook-ups.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLimitations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne-Piece Band with Type T2 or Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diameter:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eTwo-Piece Band with Type T2 or Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diamter:\u003c\/strong\u003e 4\" (101.6 mm)  \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMin. Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eReverse Band with Type T3 Screw Terminals\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inner Diamter:\u003c\/strong\u003e 5-1\/2\" (139.7 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThree types of Igloo™ bases are available:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e \u003c\/span\u003e— Double Port In-Line P\/N CER-101-104\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e— Double Port 90° P\/N CER-101-106\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e— Single Port P\/N CER-101-107\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Igloo™ caps are available in the following screw terminal size:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e10-32 — P\/N CER-102-101\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: \u003cspan data-mce-fragment=\"1\"\u003eExposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eThree-Phase\u003c\/h4\u003e\n\u003cp\u003eOn very high wattage band heaters it would be advantageous to set up the wiring three-phase to reduce the current load across a single conductor. Three-phase wiring is available with all types of insulation, construction styles, and clamping variations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eDual Voltage\u003c\/h4\u003e\n\u003cp\u003eBand heaters can be designed using 3-wire series\/parallel circuits for dual voltage applications. Whether the heater is run on the high or low voltage, the wattage will be the same. Dual Voltage wiring is available with all types of insulation, construction styles, or clamping variations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eSingle-Phase\/Three-Phase\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCeramic Band Heaters can be designed with multiple circuits to operate single or three-phase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eElectrical Plugs\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eIndustry standard NEMA twist lock electrical connectors are available. The plugs can be attached to fiberglass leads, armor cable or wire braid. Electrical Plugs can be added to any termination variation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTerminal Lugs\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eVarious types of crimp terminals can be attached to the heater leads to make wiring into applications quick and easy. High temperature [1200°F (649°C)] ring terminals and nylon or PVC insulated terminals are available. Spade, ring, and right-angle or straight quick disconnect type terminals can be attached to the leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eHigh Temperature Lead Wire\u003c\/h4\u003e\n\u003cp\u003eWhen required, high temperature lead wire can be used. The wire is insulated with mica tapes over the stranded nickel conductors and then treated fiberglass over-braid.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 450°C (842°F)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eGround Terminal or Lead\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor those applications requiring a separate ground terminal or lead attached to the heater sheath. A Ground Terminal or Lead is available on any construction or termination variation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e__________\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOversize Gap\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe nominal gap is 3\/8\". If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe nominal gap is 3\/8\".  If a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCommon Applications:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e"}

Tempco - Ceramic Insulated Band Heaters

Product Description

A helically wound resistance coil made from nickel-chrome wire is precisely strung through specially designed ceramic insulating bricks, forming a flexible heating mat. TEMPCO's style of Ceramic Insulating Bricks offers several benefits including:

  • Excellent dielectric strength at high temperatures with high voltages
  • Ability to interlock and provide a more rigid structure
  • Allows for heater widths in smaller increments (1/8")
  • Reduces the chances of damaging internal coils in transit and handling
  • Allows for easier installation of the heater onto the pipe

These heaters transmit heat through both conduction & radiation. The element winding is designed to heat the ceramic blocks to the point at which they radiate energy into the barrel as well as conduct energy by being in contact with the barrel - fit is not as critical as in other types of bands.

Specifications:

Performance Ratings

  • Maximum Temperature: 1400 °F (760 °C)
  • Nominal Watt Density: 20-45 w/in(3-7 w/cm2)
  • Maximum Watt Density: 45 w/in(7 w/cm2)

Electrical Ratings

  • Maximum Voltage: 480V per electrical termination.
  • Dual Voltage: Available - Depending on heater configuration.
  • Maximum Amperage per Circuit: Lead Wire terminations; 12.5 amp, Screw terminations: 25 amp.
  • Resistance Tolerance: +10%, - 5%
  • Wattage Tolerance: +5%, - 10% 

Physical Size Construction Limitations *

  • Sheath Material: Stainless Steel
  • Insulation Material: Ceramic Fiber Blanket; Standard Thickness: 1/4" (6.4 mm) - Double Thickness: 1/2" (12.7 mm). 
  • See reference page 1-62 for additional specifications and reference page 1-74 termination styles and electrical ratings.

Overall Thickness:

 Insulation Type

Diameter Less Than 4" Diameter of 4" or Greater Diameter of 4" or Greater
- Standard Standard Standard
Standard 1/2" (12.7 mm) 5/8" (15.9 mm) 1/2" (12.7 mm)
Double 11/16" (17.5 mm) 3/4" (19.1 mm) 11/16" (17.5 mm)
Ribcage (Uninsulated)
11/32" (8.7 mm) 1/2" (12.7 mm) 11/32" (8.7 mm)
  • Minimum Width: 1" (25.4 mm)
  • Standard Width Increments: 1/8" (3.2 mm) - Contact us at (844) 862-7880 for non-standard widths.
  • Maximum Width (One-Piece & Two-Piece): Dependent upon the ratio of diameter to width. Maximum Width to Diameter Ratio is 3:1 - Maximum Width for 5" or greater ID is 15".
  • Reverse Band: 4" (101.6 mm)
  • Width Tolerance: 1" (25.4 mm) to 3 1/2" (88.9 mm): ±1/16" (±1.6 mm) - 4" (101.8 mm) to 6 1/2" (165.1 mm): ±1/8" (±3.2 mm) - Over 6 1/2" (165.1 mm): ±1/4" (6.4 mm).
  • Minimum Diameter: One-Piece; 2" (50.8 mm) - Two-Piece; 4" (101.6 mm) - Reverse Band; 5 1/2" (139.7 mm).
  • Nominal Gap: 3/8" (9.5 mm) - If a larger gap is required for probes or thermocouples, then please specify when ordering.
  • See reference pages 1-63, 1-64, and 1-65 for Standard (Non-Stock) Ceramic Band specifications/ordering information.

    Note: If tighter tolerances are required, then please contact us at (844) 862-7880 for assistance.

      __________

      Design Features:

      One Piece Band

      /Tempco/Data-Assets/01-Band-Images/WebE527.jpg

      The One-Piece Ceramic Band Heater is the basic design most often specified by OEMs and processors. It is available with all types of insulation, construction styles, clamping or termination variations.

      Standard Insulation (S): 1/4"
      Built-In ceramic fiber insulation ¼" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.

      Limitations

      • Minimum Inside Diameter: 2" (50.8 mm)
      • Minimum Width: 1" (25.4 mm)
      • Maximum Inside Diameter: 21" (533.4 mm)
      • See reference pages 1-66 and 1-67 for additional construction information.

      ________________________________________

      Clamping Options (One Piece Band)

      Type B – Built-In Bracket (Standard) - One Piece Band

      The Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1/4-20. It is available with all types of insulation, construction styles, and termination variations.

        Limitations

        • Minimum Inside Diameter: 2" (50.8 mm)
        • Minimum Width: 1" (25.4 mm)
        • See reference pages 1-66 and 1-67 for additional construction information.

        __________

        Type S – Built-In Bracket with Spring-Loaded Screw - One Piece Band

        The Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.

          Limitations

          • Minimum Inside Diameter: 2" (50.8 mm)
          • Minimum Width: 1" (25.4 mm)
          • See reference pages 1-66 and 1-67 for additional construction information.

          __________

          Type L – Latch and Trunnion - One Piece Band

          The spring-loaded Latch and Trunnion clamping system is ideal for bands over 12" in diameter to absorb thermal expansion and facilitate installation on large bands.
          The Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.

            Limitations

            • Minimum Inside Diameter: 4" (101.6 mm)
            • Minimum Width: 1" (25.4 mm)
            • See reference pages 1-66 and 1-67 for additional construction information.

            __________

            Type F – Bent-Up Flange (Ears) - One Piece Band

            The Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.

              Limitations

              • Minimum Inside Diameter: 2" (50.8 mm)
              • Minimum Width: 1" (25.4 mm)
              • See reference pages 1-66 and 1-67 for additional construction information.

              __________

              Shell Overlap - One Piece Band

              The Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.

                Limitations

                • Minimum Inside Diameter: 3" (76.2 mm)
                • Minimum Width: 1 1/2" (38.1 mm)
                • Standard Hole: 3/4" (19.1 mm)
                • See reference pages 1-66 and 1-67 for additional construction information.

                ________________________________________

                Electrical Terminations (One Piece Band)

                Type T2 – Screw Terminals - One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_T2_2Pc.jpg

                Type T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2" in width unless otherwise specified. 10-32 post terminals are standard.

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/25A
                • Not available for Reverse Construction.
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                __________

                Type T3 – Screw Terminals - One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE523.jpg

                Type T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.

                • Standard Termination Location: center of each half; across center of width
                • Minimum Inside Diameter: 4" (101.6 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 2" (50.8 mm)
                • Maximum Volts/Amps: 480VAC/25A each half
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                __________

                Type L1: Straight Lead Wires – One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE517.jpg

                Type L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10" long.

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/12.5A
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                __________

                Type W1: Abrasion Resistant Straight Wire Braid Leads – One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE518.jpg

                Straight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10" of wire braid over 12" of flexible leads.

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/12.5A
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                Note: Stainless steel construction may be required for widths of 7/8" (22.2 mm) to 1-5/8" (41.3 mm). 

                __________

                Type W2M: Right-Angle Wire Braid Leads, 90° to Heater - One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE544.jpg

                Stainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/12.5A
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                Note: If longer leads are required, specify when ordering.

                __________

                Type W5M: Right-Angle Wire Braid Leads, Parallel to Heater - One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE543.jpg

                Stainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/12.5A
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                __________

                Type R1: Abrasion Resistant Straight Armor Cable - One Piece Band

                /Tempco/Data-Assets/01-Band-Images/WebE520.jpg

                Straight Armor Cable is available with all types of insulation, construction styles, and clamping variations. Armor cable provides far superior protection to lead wires where abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10" of armor cable over 12" of flexible leads.

                R1A – Galvanized Steel Armor Cable

                R1B – Stainless Steel Armor Cable

                • Standard Termination Location: opposite the gap; center of width
                • Minimum Inside Diameter: 2" (50.8 mm)
                • Reverse Band:  5-1/2" (139.7 mm)
                • Minimum Width: 1" (25.4 mm)
                • Maximum Volts/Amps: 480VAC/12.5A
                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                  Note: Stainless steel construction may be required for widths of 7/8" (22.2 mm) to 1-5/8" (41.3 mm).

                  __________

                  Strain Relief (One Piece Band)

                  Type S1: Lead Wire Spring Strain Relief - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE519.jpg

                  A strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5/8" long. The flexible standard leads are 10" long with 2-1/2" of fiberglass sleeving.

                  S1A – Plain Leads and Strain Relief Spring

                  S1B – Stainless Steel Wire Braided Leads and Strain Relief Spring

                  • Standard Termination Location: opposite the gap; center of width
                  • Minimum Inside Diameter: 2" (50.8 mm)
                  • Reverse Band:  5-1/2" (139.7 mm)
                  • Minimum Width: 1" (25.4 mm)
                  • Maximum Volts/Amps: 480VAC/12.5A

                  ________________________________________

                  Standard & Low-Profile Terminal Boxes (One Piece Band)

                  Type C2 – Standard Terminal Box - One-Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE530.jpg

                  Terminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.

                  The Heavy Duty Terminal Boxes have a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7/8". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.

                  C2A – Box only
                  C2B – with galvanized armor
                  C2C – with stainless steel armor
                  C2D – with wire braid

                  Box Size: 1-1/2"H × 1-1/2"W × 2-1/2"L for bands 1-1/2" to 2" wide
                  Box Size: 1-1/2"H × 2-1/8"W × 2-1/8"L for bands greater than 2" wide

                  • Standard Termination Location: opposite the gap; center of width
                  • Minimum Inside Diameter: 2" (50.8 mm)
                  • Reverse Band:  15" (381 mm)
                  • Minimum Width: 1-1/2" (38.1 mm)
                  • Maximum Volts/Amps: 480VAC/25A

                  Note: Heater dimensions will determine terminal configuration.

                  Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

                  __________

                  Type C5: Low-Profile Terminal Box - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE534.jpg

                  Terminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.

                  The Heavy Duty Terminal Boxes have a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7/8". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.

                  C5A – Box only
                  C5B – with galvanized armor
                  C5C – with stainless steel armor
                  C5D – with wire braid
                  C5J – box with lead wire

                  Box Size: 1"H × 1-1/4"W × 3"L for bands 1-1/2" to 2" wide
                  Box Size: 1"H × 2-1/4"W × 2"L for bands greater than 2" wide

                  • Standard Termination Location: Opposite the gap; Center of width
                  • Minimum Inside Diameter: 2" (50.8 mm)
                  • ​​​​​​​Reverse Band:  15" (381 mm)
                  • Minimum Width: 1-1/2" (38.1 mm)
                  • Maximum Volts/Amps: 480VAC/25A

                  Note: 

                  1. Heater dimensions will determine terminal configuration.
                  2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.

                  Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

                  ________________________________________

                  Standard & Low-Profile Quick Disconnect Plugs (One Piece Band)

                  Type P1: Quick Disconnect Plugs - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebF519.jpg

                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                  Type P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                  • Standard Termination Location: Opposite the gap; Center of width
                  • Minimum Inside Diameter: 2" (50.8 mm)
                  • Reverse Band:  5-1/2" (139.7 mm)
                  • Minimum Width: 2" (50.8 mm) depending on termination orientation

                  Plug Electrical Ratings

                  • 2-Pole 3-Wire Grounding
                  • Maximum Volts: 250 VAC
                  • Maximum Amps: 16A
                  • Maximum Temperature: 392°F (200°C)

                  P1K – Cup Assembly only
                  P1L – w/straight plug only
                  P1M – w/90° plug only
                  P1N – w/straight plug & galvanized armor cable
                  P1O – w/straight plug & stainless steel armor cable
                  P1P – w/straight plug & wire braid
                  P1Q – w/90° plug & galvanized armor cable
                  P1R – w/90° plug & stainless steel armor cable
                  P1S – w/90° plug & wire braid

                  __________

                  Type P2: Quick Disconnect Plugs, Low-Profile - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE515.jpg

                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                  Note: Type P2 plug assemblies have a lower profile and are available with a straight plug only.

                  • Standard Termination Location: Opposite the gap; Center of width
                  • Minimum Inside Diameter: 2" (50.8 mm)
                  • Reverse Band:  Consult Tempco with your requirements.
                  • Minimum Width: 2" (50.8 mm)

                  Plug Electrical Ratings

                  • 2-Pole 3-Wire Grounding
                  • Maximum Volts: 250 VAC
                  • Maximum Amps: 16A
                  • Maximum Temperature: 392°F (200°C)

                  P1K – Cup Assembly only
                  P1L – w/straight plug only
                  P1M – w/90° plug only
                  P1N – w/straight plug & galvanized armor cable\
                  P1O – w/straight plug & stainless steel armor cable
                  P1P – w/straight plug & wire braid
                  P1Q – w/90° plug & galvanized armor cable/
                  P1R – w/90° plug & stainless steel armor cable
                  P1S – w/90° plug & wire braid

                  ________________________________________

                  Vertical & Horizontal Quick Disconnect Plugs (One Piece Band)

                  Type P3: Din 49458 A/B Quick Disconnect Plugs, Vertical - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE501.jpg

                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                  Type P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                  • Standard Termination Location: Opposite the gap; Center of width
                  • Minimum Inside Diameter: 3" (76.2 mm)
                  • Reverse Band:  Consult Tempco with your requirements.
                  • Minimum Width: 2" (50.8 mm)

                  Plug Electrical Ratings

                  • 2-Pole 3-Wire Grounding
                  • Maximum Volts: 250 VAC
                  • Maximum Amps: 16A
                  • Maximum Temperature: 392°F (200°C)

                  P3A – Box assembly only
                  P3B – Box assembly w/straight plug
                  P3C – Box assembly w/right-angle plug

                  __________

                  Type P4: Din 49458 A/B Quick Disconnect Plugs, Horizontal - One Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebF521.jpg

                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                  Type P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                  • Standard Termination Location: Opposite the gap; Center of width
                  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
                  • Reverse Band:  Consult Tempco with your requirements.
                  • Minimum Width: 2-1/2" (63.5 mm)

                  Plug Electrical Ratings

                  • 2-Pole 3-Wire Grounding
                  • Maximum Volts: 250 VAC
                  • Maximum Amps: 16A
                  • Maximum Temperature: 392°F (200°C)

                  P4A – Box assembly only
                  P4B – Box assembly w/straight plug

                  ________________________________________

                  Two Piece Band

                  /Tempco/Data-Assets/01-Band-Images/WebE528.jpg

                  The Two-Piece Ceramic Band Heater is commonly used on sizes larger than 21" diameter or when it would be inconvenient to use a one-piece heater. It is available with all types of insulation, construction styles, clamping or termination variations.

                  Standard Insulation (S): 1/4"
                  Built-In ceramic fiber insulation ¼" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.

                  Limitations

                  • Minimum Inside Diameter: 4" (101.6 mm)
                  • Minimum Width:  1" (25.4 mm)
                  • Maximum Inside Diameter: 44" (1118 mm)

                    Note: Larger sizes are manufactured in multiple sections. Watts and volts are specified per each section when ordering.

                    ________________________________________

                    Clamping Options (Two-Piece Band)

                    Type B – Built-In Bracket (Standard) - Two Piece Band

                    The Built-In Bracket is the basic design most often specified by OEMs and processors. The standard screw used is 1/4-20. It is available with all types of insulation, construction styles, and termination variations.

                      Limitations

                      • Minimum Inside Diameter: 4" (101.6 mm)
                      • Minimum Width: 1" (25.4 mm
                      • See reference pages 1-66 and 1-67 for additional construction information.

                      __________

                      Type S – Built-In Bracket with Spring-Loaded Screw - Two Piece Band

                      The Built-In Bracket can also be supplied with a spring- loaded screw. The spring-loaded clamp aids in absorbing thermal expansion.

                        Limitations

                        • Minimum Inside Diameter: 4" (101.6 mm)
                        • Minimum Width: 1" (25.4 mm)
                        • See reference pages 1-66 and 1-67 for additional construction information.

                        __________

                        Type L – Latch and Trunnion - Two Piece Band

                        The spring-loaded Latch and Trunnion clamping system is ideal for bands over 12" in diameter to absorb thermal expansion and facilitate installation on large bands.
                        The Latch and Trunnion clamping system is available with all types of insulation, construction styles, and termination variations.

                          Limitations

                          • Minimum Inside Diameter: 4" (101.6 mm)
                          • Minimum Width: 2" (50.8 mm)
                          • See reference pages 1-66 and 1-67 for additional construction information.

                            __________

                            Type F - Bent-Up Flange (Ears) - Two Piece Band

                            The Bent-Up Flange (Ears) design is available with all types of insulation, construction styles, and termination variations.

                            Limitations

                            • Minimum Inside Diameter: 4" (101.6 mm)
                            • Minimum Width: 2.5" (63.5 mm)
                            • See reference pages 1-66 and 1-67 for additional construction information.

                              __________

                              Shell Overlap - Two-Piece Band

                              The Shell Overlap design is the preferred method of providing a thermocouple mounting hole in a ceramic band heater. It is available with all types of insulation, construction styles, clamping and termination variations.

                              Limitations

                              • Minimum Inside Diameter: 4" (101.6 mm)
                              • Minimum Width: 2" (50.8 mm)
                              • Standard Hole: 3/4" (19.1 mm)
                              • See reference pages 1-66 and 1-67 for additional construction information.

                                ________________________________________

                                Electrical Terminations (Two Piece Band)

                                Type T2 – Screw Terminals - Two Piece Band

                                /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_T2_2Pc.jpg

                                Type T2 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters under 2" in width unless otherwise specified. 10-32 post terminals are standard.

                                • Standard Termination Location: Center of each half; center of width
                                • Minimum Inside Diameter: 4" (101.6 mm)
                                • Minimum Width: 1" (25.4 mm)
                                • Maximum Volts/Amps: 480VAC/25A each half
                                • See reference pages 1-68 and 1-69 for additional electrical termination information.
                                __________

                                Type T3 – Screw Terminals - Two Piece Band

                                /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_T3_2Pc.jpg

                                Type T3 Screw Terminals are available with all types of insulation, construction styles, and clamping variations. They are considered to be standard on most band heaters unless otherwise specified. For use with leads, crimp terminals, or bus bars.

                                • Standard Termination Location: center of each half; across center of width
                                • Minimum Inside Diameter: 4" (101.6 mm)
                                • Reverse Band:  5-1/2" (139.7 mm)
                                • Minimum Width: 2" (50.8 mm)
                                • Maximum Volts/Amps: 480VAC/25A each half
                                • See reference pages 1-68 and 1-69 for additional electrical termination information.

                                __________

                                Type L1: Straight Lead Wires - Two Piece Band

                                /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_L1_2Pc.jpg

                                Type L1 Straight Lead Wires are available with all types of insulation, construction styles, and clamping variations. They are used primarily on small diameter bands where clearance is limited. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard flexible leads are 10" long.

                                • Standard Termination Location: center of each half; center of width
                                • Minimum Inside Diameter: 4" (101.6 mm)
                                • Reverse Band:  5-1/2" (139.7 mm)
                                • Minimum Width: 1" (25.4 mm)
                                • Maximum Volts/Amps: 480VAC/12.5A each half
                                • See reference pages 1-68 and 1-69 for additional electrical termination information.
                                __________

                                  Type W1: Abrasion Resistant Straight Wire Braid Leads - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_W1_2Pc.jpg

                                  Straight Wire Braid Leads are available with all types of insulation, construction styles, and clamping variations. Wire braid leads offer sharp bending not possible with armor cable. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10" of wire braid over 12" of flexible leads.

                                  • Standard Termination Location: center of each half; center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Maximum Volts/Amps: 480VAC/12.5A each half
                                  • See reference pages 1-68 and 1-69 for additional electrical termination information.

                                   __________

                                  Type W2M: Right-Angle Wire Braid Leads, 90° to Heater - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_W2M_2Pc.jpg

                                  Stainless Steel Wire Braid exits perpendicular to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

                                  • Standard Termination Location: Center of each half; center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Maximum Volts/Amps: 480VAC/12.5A each half
                                  • See reference pages 1-68 and 1-69 for additional electrical termination information.

                                  Note: If longer leads are required, specify when ordering.

                                   __________

                                  Type W5M: Right-Angle Wire Braid Leads, Parallel to Heater - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_W5M_2Pc.jpg

                                  Stainless Steel Wire Braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap acts as a strain relief which protects against excessive flexing or pulling of the lead wire. The standard leads are 10" of wire braid over 12" of flexible leads.

                                  • Standard Termination Location: Opposite the gap; Center of width
                                  • Minimum Inside Diameter: 2" (50.8 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Maximum Volts/Amps: 480VAC/12.5A
                                  • See reference pages 1-68 and 1-69 for additional electrical termination information.

                                  Note: If longer leads are required, specify when ordering.

                                   __________

                                  Type R2: Abrasion Resistant Right-Angle Armor Cable, Two Piece Band

                                   /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_R2_2Pc.jpg

                                  Right-Angle Armor Cable is available with all types of insulation, construction styles, and clamping variations. It is used where space is limited and abrasion is a constant problem. If applicable, screw terminals should always be specified due to the high heat generated by ceramic bands. The standard leads are 10" of armor cable over 12" of flexible leads.

                                  R2A – Galvanized Steel Armor Cable

                                  R2B – Stainless Steel Armor Cable

                                  • Standard Termination Location: center of each half; center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Maximum Volts/Amps: 480VAC/12.5A each half
                                  • See reference pages 1-68 and 1-69 for additional electrical termination information.

                                  Note: Stainless steel construction may be required for widths of 7/8" (22.2 mm) to 1-5/8" (41.3 mm).

                                  ________________________________________

                                  Strain Relief (Two Piece Band)

                                  Type S1: Lead Wire Spring Strain Relief - Two Piece Band

                                   /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_S1_2Pc.jpg

                                  A strain relief spring is attached to the heater at the termination exit to reduce strain on leads subjected to excessive flexing. The spring is 2-5/8" long. The flexible standard leads are 10" long with 2-1/2" of fiberglass sleeving.

                                  S1A – Plain Leads and Strain Relief Spring

                                  S1B – Stainless Steel Wire Braided Leads and Strain Relief Spring

                                  • Standard Termination Location: Center of each half; Center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Maximum Volts/Amps: 480VAC/12.5A each half

                                   ________________________________________

                                  Standard & Low-Profile Terminal Boxes (Two Piece Band)

                                  Type C2 – Standard Terminal Box - Two Piece Band

                                   /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_C2_2Pc.jpg

                                  Terminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.

                                  The Heavy Duty Terminal Boxes have a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7/8". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.

                                  C2A – Box only
                                  C2B – with galvanized armor
                                  C2C – with stainless steel armor
                                  C2D – with wire braid

                                  Box Size: 1-1/2"H × 1-1/2"W × 2-1/2"L for bands 1-1/2" to 2" wide
                                  Box Size: 1-1/2"H × 2-1/8"W × 2-1/8"L for bands greater than 2" wide

                                  • Standard Termination Location: Center of each half; Center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • ​​​​​​​Reverse Band:  15" (381 mm)
                                  • Minimum Width: 1-1/2" (38.1 mm)
                                  • Maximum Volts/Amps: 480VAC/25A each half

                                  __________

                                  Type C5 – Low-Profile Terminal Box - Two Piece Band

                                  Terminal Boxes are available with all types of insulation, construction styles, or clamping variations. It is a simple and economical way to protect employees from electric shock or prevent electric shorts that can result from exposed wiring on band heater electrical installations.

                                  The Heavy Duty Terminal Boxes have a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. The boxes can be field assembled on band heaters that have a center distance between screws of 7/8". To simplify installation the boxes can be pre-wired with galvanized armor, stainless steel armor, or wire braid.

                                  C5A – Box only
                                  C5B – with galvanized armor
                                  C5C – with stainless steel armor
                                  C5D – with wire braid
                                  C5J – box with lead wire

                                  Box Size: 1"H × 1-1/4"W × 3"L for bands 1-1/2" to 2" wide
                                  Box Size: 1"H × 2-1/4"W × 2"L for bands greater than 2" wide

                                  • Standard Termination Location: Center of each half; Center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • ​​​​​​​Reverse Band:  15" (381 mm)
                                  • Minimum Width: 1-1/2" (38.1 mm)
                                  • Maximum Volts/Amps: 480VAC/25A each half

                                  Note: 

                                  1. Heater dimensions will determine terminal configuration.
                                  2. If a Low Profile Box with cable or leads is required, it is strongly recommended to order it pre-wired by the factory.

                                  Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

                                  ________________________________________

                                  Standard & Low-Profile Quick Disconnect Plugs (Two Piece Band)

                                  Type P1: Quick Disconnect Plugs - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_P1_2Pc.jpg

                                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                                  Type P1 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                                  • Standard Termination Location: center of each half; center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  5-1/2" (139.7 mm)
                                  • Minimum Width: 2" (50.8 mm) depending on termination orientation

                                  Plug Electrical Ratings

                                  • 2-Pole 3-Wire Grounding
                                  • Maximum Volts: 250 VAC
                                  • Maximum Amps: 16A
                                  • Maximum Temperature: 392°F (200°C)

                                  P1K – Cup Assembly only
                                  P1L – w/straight plug only
                                  P1M – w/90° plug only
                                  P1N – w/straight plug & galvanized armor cable
                                  P1O – w/straight plug & stainless steel armor cable
                                  P1P – w/straight plug & wire braid
                                  P1Q – w/90° plug & galvanized armor cable
                                  P1R – w/90° plug & stainless steel armor cable
                                  P1S – w/90° plug & wire braid

                                  __________

                                  Type P2: Quick Disconnect Plugs, Low-Profile - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_P2_2Pc.jpg

                                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                                  Note: Type P2 plug assemblies have a lower profile and are available with a straight plug only.

                                  • Standard Termination Location: center of each half; center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  Consult Tempco with your requirements.
                                  • Minimum Width: 2" (50.8 mm)

                                  Plug Electrical Ratings

                                  • 2-Pole 3-Wire Grounding
                                  • Maximum Volts: 250 VAC
                                  • Maximum Amps: 16A
                                  • Maximum Temperature: 392°F (200°C)

                                  P1K – Cup Assembly only
                                  P1L – w/straight plug only
                                  P1M – w/90° plug only
                                  P1N – w/straight plug & galvanized armor cable
                                  P1O – w/straight plug & stainless steel armor cable
                                  P1P – w/straight plug & wire braid
                                  P1Q – w/90° plug & galvanized armor cable
                                  P1R – w/90° plug & stainless steel armor cable
                                  P1S – w/90° plug & wire braid

                                  ________________________________________

                                  Vertical & Horizontal Quick Disconnect Plugs (Two Piece Band)

                                  Type P3: Din 49458 A/B Quick Disconnect Plugs, Vertical - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_P3_2Pc.jpg

                                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                                  Type P3 assemblies are available with a straight or right-angle plug. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                                  • Standard Termination Location: Center of each half; Center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  Consult Tempco with your requirements.
                                  • Minimum Width: 2" (50.8 mm)

                                  Plug Electrical Ratings

                                  • 2-Pole 3-Wire Grounding
                                  • Maximum Volts: 250 VAC
                                  • Maximum Amps: 16A
                                  • Maximum Temperature: 392°F (200°C)

                                  P3A – Box assembly only
                                  P3B – Box assembly w/straight plug
                                  P3C – Box assembly w/right-angle plug

                                  __________

                                  Type P4: Din 49458 A/B Quick Disconnect Plugs, Horizontal - Two Piece Band

                                  /Tempco/Data-Assets/01-Band-Images/WebCrmcBand_P4_2Pc.jpg

                                  Quick Disconnect Plugs are available on any construction or clamping variation. These quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminates all live exposed terminals or wiring that can be a potential hazard to employees or machinery.

                                  Type P4 plug assemblies have a lower profile and are available with a straight plug only. To simplify installation, band heaters with these assemblies can be supplied pre-wired using high temperature lead wire protected with armor cable.

                                  • Standard Termination Location: Center of each half; Center of width
                                  • Minimum Inside Diameter: 4" (101.6 mm)
                                  • Reverse Band:  Consult Tempco with your requirements.
                                  • Minimum Width: 2-1/2" (63.5 mm)

                                  Plug Electrical Ratings

                                  • 2-Pole 3-Wire Grounding
                                  • Maximum Volts: 250 VAC
                                  • Maximum Amps: 16A
                                  • Maximum Temperature: 392°F (200°C)

                                  P4A – Box assembly only
                                  P4B – Box assembly w/straight plug

                                  ________________________________________

                                  Reverse Band

                                  /Tempco/Data-Assets/01-Band-Images/WebE541.jpg

                                  Reverse Ceramic Band Heaters are intended for the outer surface of the band to heat the inner surface of a cylinder. These heaters use the same built-in insulation as normal ceramic bands and therefor can either reduce the power needed to heat an application to the desired temperature or offer some thermal protection to anything else that might also be inside the cylinder.

                                  Standard Insulation (S): 1/4"
                                  Built-In ceramic fiber insulation ¼" thick standard on all Ceramic Bands will reduce power consumption by 25 to 30 percent, and lower external temperatures.

                                  The specially designed internal brackets exert outward pressure to ensure good contact with the application surface. To aid in holding the internal components together during installation, reverse ceramic bands are supplied with a perforated stainless steel outer liner.

                                  The outer diameter is the distinguishing characteristic and should match the inner diameter of the cylinder to be heated.  If airflow is needed for cooling, Tempco’s Type R Uninsulated Ceramic Band with a perforated sheath is also available. This is also the same robust construction that can reach higher temperatures than other heater bands.

                                  Limitations

                                  • Minimum Inside Diameter: 5-1/2" (139.7 mm)
                                  • Minimum Width:  1" (25.4 mm)
                                  • Maximum Inside Diameter: 44" (1118 mm)
                                  • Maximum Width: 4" (101.6 mm)
                                  • See reference pages 1-66 and 1-67 for additional construction information.

                                  ________________________________________

                                  Additional Options:

                                  Optional Double Insulation (D): 1/2

                                  /Tempco/Data-Assets/01-Band-Images/WebE533.jpg

                                  Standard built-In ceramic fiber insulation 1/4" thick on all Ceramic Bands; will reduce power consumption by 25 to 30 percent and lower external temperatures (when compared to uninsulated band heaters).
                                  Optional built-in ceramic fiber insulation 1/2" thick is available; for situations requiring additional insulation for lower external temperatures and increased electrical energy savings. This will decrease power consumption by 35 to 37 percent (when compared to uninsulated band heaters).

                                  Note: Not available for Reverse Construction.

                                  __________

                                  Type R: Uninsulated Ceramic Band Heaters

                                  /Tempco/Data-Assets/01-Band-Images/WebE531.jpg
                                  Type R Construction is an uninsulated ceramic band heater with a perforated Stainless Steel outer shell for more efficient cooling.  It is typically used in multiple quantities with forced air cooling systems such as Tempco's Cool TO-THE Touch Shroud Systems (see Type RCC below).

                                  Performance Ratings

                                  • Maximum Watt Density: 50 W/in2 (8 W/cm2)
                                  • Maximum Temperature: 900°F (482°C)

                                  Mechanical Ratings

                                  • Standard Width Increments: 1/8" 3.2 cm
                                  • Maximum Width: depends on ratio of diameter to width
                                  • Minimum Width: 1" (25.4 mm)
                                  • Standard Gap: 3/8" ±1/8" (9.5 ±3.2 mm)

                                  Electrical Ratings

                                  • Resistance tolerance: +10%, –5%
                                  • Wattage tolerance: +5%, –10%
                                  • Maximum Voltage: 480 single or 3-phase (when applicable)
                                  • Maximum Amperage:
                                  • Screw Terminals: 25 Amps per circuit
                                  • Lead Wire: 10 Amps per circuit

                                  __________

                                  Type RCC: (Ribcage) Heating Mounting Configuration


                                  /Tempco/Data-Assets/01-Band-Images/WebA604.jpg

                                  This system was developed to reduce the cost and weight of typical shroud systems for the heating and cooling of high temperature extrusion processes.  Type RCC (Rib Cage) Air Cooled Systems use multiple Type R Ceramic Band Heaters under one shroud.

                                  • These low mass, non-thermally insulated ceramic band heaters work in tandem with a highly efficient stainless steel sheet metal shroud and are typically arranged with spaces between the heaters to enhance the cooling of the barrel when external heat is no longer required.
                                  • Forced air blowers are used for cooling. The ambient airflow enters the shroud, circulates around the ceramic heater and barrel, removes the heat from the heater and the process and exits the shroud opposite the entrance port.
                                  • The Cool TO-THE Touch dual layer shroud uses an inner stainless steel solid layer thermally isolated from the heater, providing a path for the forced cooling air. An outer Stainless Steel perforated layer provides optimal venting and heat dissipation while providing personnel safety.

                                  __________

                                  Igloo® Ceramic Terminal Covers

                                   Type C6: Double Port In-Line

                                  Type C6: Double Port In-Line

                                  Type C7: Double Port 90°

                                  Type C7: Double Port 90°

                                  Type C8: Single Port 90°

                                  Type C8: Single Port 90°

                                   

                                  Igloo™ Ceramic Terminal Covers consist of two individual ceramic parts. They are available with all types of insulation, construction styles, and clamping variations. Unlike conventional ceramic caps, Igloo fully insulates any standard #10 terminal lugs used for electrical hook-ups.

                                  Limitations:

                                  One-Piece Band with Type T2 or Type T3 Screw Terminals

                                  • Minimum Inner Diameter: 2" (50.8 mm)
                                  • Minimum Width: 1" (25.4 mm)
                                  • Two-Piece Band with Type T2 or Type T3 Screw Terminals
                                  • Minimum Inner Diamter: 4" (101.6 mm)  
                                  • Min. Width: 1" (25.4 mm)
                                  • Reverse Band with Type T3 Screw Terminals
                                  • Minimum Inner Diamter: 5-1/2" (139.7 mm)

                                  Three types of Igloo™ bases are available:

                                  Type C6 — Double Port In-Line P/N CER-101-104
                                  Type C7 — Double Port 90° P/N CER-101-106
                                  Type C8 — Single Port P/N CER-101-107

                                  Note: Igloo™ caps are available in the following screw terminal size:
                                  10-32 — P/N CER-102-101

                                  Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

                                  __________

                                  Three-Phase

                                  On very high wattage band heaters it would be advantageous to set up the wiring three-phase to reduce the current load across a single conductor. Three-phase wiring is available with all types of insulation, construction styles, and clamping variations.

                                  • Minimum Width: 3" (76.2 mm)

                                  __________

                                  Dual Voltage

                                  Band heaters can be designed using 3-wire series/parallel circuits for dual voltage applications. Whether the heater is run on the high or low voltage, the wattage will be the same. Dual Voltage wiring is available with all types of insulation, construction styles, or clamping variations.

                                  • Minimum width: 2" (50.8 mm)

                                  __________

                                  Single-Phase/Three-Phase

                                  Ceramic Band Heaters can be designed with multiple circuits to operate single or three-phase.

                                  __________

                                  Electrical Plugs

                                  Industry standard NEMA twist lock electrical connectors are available. The plugs can be attached to fiberglass leads, armor cable or wire braid. Electrical Plugs can be added to any termination variation.

                                  __________

                                  Terminal Lugs

                                  Various types of crimp terminals can be attached to the heater leads to make wiring into applications quick and easy. High temperature [1200°F (649°C)] ring terminals and nylon or PVC insulated terminals are available. Spade, ring, and right-angle or straight quick disconnect type terminals can be attached to the leads.

                                  __________

                                  High Temperature Lead Wire

                                  When required, high temperature lead wire can be used. The wire is insulated with mica tapes over the stranded nickel conductors and then treated fiberglass over-braid.

                                  • Maximum Temperature: 450°C (842°F)

                                  __________

                                  Ground Terminal or Lead

                                  For those applications requiring a separate ground terminal or lead attached to the heater sheath. A Ground Terminal or Lead is available on any construction or termination variation.

                                  __________

                                  Oversize Gap

                                  The nominal gap is 3/8". If a larger gap is required for probes or thermocouples, specify when ordering.

                                  The nominal gap is 3/8".  If a larger gap is required for probes or thermocouples, specify when ordering.

                                  Common Applications:

                                  • Autoclaves & Sterilizers
                                  • Blow Molding Machines (Barrels & Heads)
                                  • Blown Film Dies
                                  • Drum Heating
                                  • Extrusion Die
                                  • Fluidized Beds
                                  • Food & Candy Extruders
                                  • Food Service Warming Pots
                                  • Holding Tanks
                                  • Hot Runner Molding Bushings
                                  • Metallurgical Analyzation Equipment
                                  • Oil Reclamation Systems
                                  • Plastic Extruders
                                  • Plastic Injection Molding Machines
                                  • Pulp & Paper Processing Equipment
                                  • Vending Machines