{"id":4305999986765,"title":"HCS 1\/32 DIN Fuzzy Logic Temperature\/Process Controllers","handle":"products-heaters-controls-and-sensors-132-din-fuzzy-logic-temperatureprocess-controllers","description":"\u003cp\u003e\u003cspan style=\"color: #333333;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e\u003cem\u003eFuzyPro 1\/32 DIN Fuzzy Logic Temperature\/Process Controller for controlling temperature, humidity, pressure, flow, pH, detecting voltage, current, power, and phase failure.\u003c\/em\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial; font-size: medium;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eFuzzy Logic is an artificial intelligence technique that can make decisions based on vague or incomplete information—providing perfect control results. Though the basis is precise microprocessor technology, Fuzzy Logic uses linguistic descriptions to define input correlations and expected outcomes. The result of Fuzzy Logic is that initial overshoot and excursions from the set point due to process disturbances are eliminated. The process can be controlled with minimum or no temperature variations.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/32 DIN Fuzzy Logic \u003cspan\u003eTemperature\/Process Controllers\u003c\/span\u003e Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003ePID - FUZZY or ON\/OFF control \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeating\/Cooling + 2 Alarms \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eField input selection TC, RTD, Linear \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOutputs Relay, Pulsed DC, 4 - 20 mAmps \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eDual display red \/ green + LED% output \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSelf tuning with inhibited overshoot \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eLow Panel depth 31\/8\" (80 mm) \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e16 Ramp\/Dwell Segments option \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeater Saver power limit function \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eMultiple alarms on a single output \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eScalable linear input \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eRapid Cycling controls faster systems \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eCustomized operator interface \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSet Point Range limit \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003ePlug in from front \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOperator Lockout Security setting \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/16 DIN Fuzzy Logic Temperature Controllers Specifications:\u003c\/h2\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eAC 85 to 265 Volts 50\/60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eAbout 4 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eMemory Element\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eEPROM 10 Years Data Rentention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eWithin 0.2% of Displayed Value + 1 Digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSampling Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eInput to Output Seperate Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDielectric\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1000 V AC 1 Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eDC 500 V \u0026lt; IO M ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e14° - 122° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0 - 90% RH Non Consuming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro Ordering Information\u003c\/h2\u003e\n\u003ctable style=\"border-style: solid; border-color: grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003ePART #: A B C D E F G\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eA: Model\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003eF 16 = 1\/16 DIN 48 mm X 48 mm PID\/Fuzzy Control\u003cbr\u003eF 18 = 1\/8 DIN 48 mm X 96 mm PID\/Fuzzy Control\u003cbr\u003eF 14 = 1\/4 DIN 96 mm X 96 mm PID\/Fuzzy Control\u003cbr\u003eF 16P = 1\/16 DIN 48 mm X 48 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable \u003cbr\u003eF 18P = 1\/8 DIN 48 mm X 96 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable\u003cbr\u003eF 14P = 1\/4 DIN 96 mm X 96 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eB: Output 1 Control Output Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - Relay contact, SPST 3A\/240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 3 to 32 DC voltage pulse, 20 VDC\/20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Current, 4-20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 - SSR Output 1.1 Amp 240 Volts\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eC: \u003cspan\u003eOutput 2 Control Output Type\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - Relay Contact, SPST 3A\/240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 3 to 32 DC voltage pulse, 20 VDC\/20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Current, 4-20 mA \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 - SSR Output 1.1 Amp 240 Volts\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eD: Alarms\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - One alarm Relay 3A 240 volts SPST \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - Two Alarm Relays 3A 240 Volts SPST \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Three Alarms only available with single control Output or F14\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eE: Transmitter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - 0-20 mA (adjustable)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 -12 volts DC output Transducer power supply\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eF: Second Input\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - 4 - 20 mAmps remote Setpoint\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 0 to 20 mAmps remote Setpoint\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Heater Break Alarm\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2019-10-24T10:45:57-04:00","created_at":"2019-10-24T10:45:58-04:00","vendor":"IHS | Industrial Heat Sources","type":"HCS 1\/32 DIN Fuzzy Logic Temperature\/Process Controllers","tags":["Controllers\/Sensors","HCS","Process Heat"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986914201677,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCS-1\/32DIN-FLT\/PC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS 1\/32 DIN Fuzzy Logic Temperature\/Process Controllers","public_title":null,"options":["Default Title"],"price":0,"weight":227,"compare_at_price":null,"inventory_management":null,"barcode":"HCS-1\/32DIN-FLT\/PC","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/132DINFuzycontrols_1.jpg?v=1572456365"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/132DINFuzycontrols_1.jpg?v=1572456365","options":["Title"],"media":[{"alt":"HCS 1\/32 DIN Fuzzy Logic Temperature\/Process Controllers","id":5533306257485,"position":1,"preview_image":{"aspect_ratio":1.766,"height":184,"width":325,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/132DINFuzycontrols_1.jpg?v=1572456365"},"aspect_ratio":1.766,"height":184,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/132DINFuzycontrols_1.jpg?v=1572456365","width":325}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan style=\"color: #333333;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e\u003cem\u003eFuzyPro 1\/32 DIN Fuzzy Logic Temperature\/Process Controller for controlling temperature, humidity, pressure, flow, pH, detecting voltage, current, power, and phase failure.\u003c\/em\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial; font-size: medium;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eFuzzy Logic is an artificial intelligence technique that can make decisions based on vague or incomplete information—providing perfect control results. Though the basis is precise microprocessor technology, Fuzzy Logic uses linguistic descriptions to define input correlations and expected outcomes. The result of Fuzzy Logic is that initial overshoot and excursions from the set point due to process disturbances are eliminated. The process can be controlled with minimum or no temperature variations.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/32 DIN Fuzzy Logic \u003cspan\u003eTemperature\/Process Controllers\u003c\/span\u003e Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003ePID - FUZZY or ON\/OFF control \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeating\/Cooling + 2 Alarms \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eField input selection TC, RTD, Linear \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOutputs Relay, Pulsed DC, 4 - 20 mAmps \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eDual display red \/ green + LED% output \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSelf tuning with inhibited overshoot \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eLow Panel depth 31\/8\" (80 mm) \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e16 Ramp\/Dwell Segments option \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeater Saver power limit function \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eMultiple alarms on a single output \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eScalable linear input \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eRapid Cycling controls faster systems \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eCustomized operator interface \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSet Point Range limit \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003ePlug in from front \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOperator Lockout Security setting \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/16 DIN Fuzzy Logic Temperature Controllers Specifications:\u003c\/h2\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eAC 85 to 265 Volts 50\/60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eAbout 4 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eMemory Element\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eEPROM 10 Years Data Rentention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eWithin 0.2% of Displayed Value + 1 Digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSampling Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eInput to Output Seperate Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDielectric\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1000 V AC 1 Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eDC 500 V \u0026lt; IO M ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e14° - 122° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0 - 90% RH Non Consuming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro Ordering Information\u003c\/h2\u003e\n\u003ctable style=\"border-style: solid; border-color: grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003ePART #: A B C D E F G\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eA: Model\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003eF 16 = 1\/16 DIN 48 mm X 48 mm PID\/Fuzzy Control\u003cbr\u003eF 18 = 1\/8 DIN 48 mm X 96 mm PID\/Fuzzy Control\u003cbr\u003eF 14 = 1\/4 DIN 96 mm X 96 mm PID\/Fuzzy Control\u003cbr\u003eF 16P = 1\/16 DIN 48 mm X 48 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable \u003cbr\u003eF 18P = 1\/8 DIN 48 mm X 96 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable\u003cbr\u003eF 14P = 1\/4 DIN 96 mm X 96 mm PID\/Fuzzy\u003cbr\u003eControl 8 or 16 Steps programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eB: Output 1 Control Output Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - Relay contact, SPST 3A\/240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 3 to 32 DC voltage pulse, 20 VDC\/20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Current, 4-20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 - SSR Output 1.1 Amp 240 Volts\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eC: \u003cspan\u003eOutput 2 Control Output Type\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - Relay Contact, SPST 3A\/240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 3 to 32 DC voltage pulse, 20 VDC\/20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Current, 4-20 mA \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 - SSR Output 1.1 Amp 240 Volts\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eD: Alarms\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - One alarm Relay 3A 240 volts SPST \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - Two Alarm Relays 3A 240 Volts SPST \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Three Alarms only available with single control Output or F14\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eE: Transmitter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - 0-20 mA (adjustable)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 -12 volts DC output Transducer power supply\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eF: Second Input\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: left;\"\u003e\n\u003cspan\u003e0 - None\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 - 4 - 20 mAmps remote Setpoint\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 - 0 to 20 mAmps remote Setpoint\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3 - Heater Break Alarm\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}