{"id":4306011652173,"title":"HCS Temperature \/ Humidity Logger","handle":"products-hcs-barnant-temperature-humidity-logger","description":"\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMeasure temperature and humidity with one instrument\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAccepts two type J, K,or T thermocouple probes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStandby mode conserves batteries while logging data\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eOptional software for bi-directional\u003cspan style=\"font-family: verdana, geneva;\"\u003e RS-232 communications\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStores 850 pairs of measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eUse the benchtop \u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003e almost anywhere temperature and humidity needs to be monitored - laboratories, museums, art galleries, warehouses, protected outdoor environments, and more! The logger operates in three modes: two-channel temperature, humidity\/temperature, and dew point\/temperature.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eThis compact, portable \u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003e is packed with features. Non-volatile memory stores setup conditions (interval time or total logging time), thermocouple probe type, logged\/stored parameters, and peak\/valley values for each mode. Serial input\/output allows for printer and computer compatibility, optional data analysis software and serial printer available.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eMeasure and display either differential (DT) temperature or dual temperature simultaneously in the two-channel temperature mode. The \u003cspan style=\"font-size: small;\"\u003etemperature \/ humidity logger\u003c\/span\u003e accepts one or two type J, K, or T thermocouple probes with ANSI miniconnectors. Features in this mode include autocalibration of probe, selectable °F or °C scale, selectable 0.1%\/1° resolution up to 999.9° (1° above 999.9°), dual analog temperature output, and accuracy of ±0.1% of reading.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eMeasure and display both relative humidity and temperature (RTD) in the humidity\/temperature mode. Use one of two interchangeable relative humidity\/temperature probes. Wide-range probe 637-0050 has a compensated RH range from 0 to 100%. General-purpose probe 637-0052 has a compensated RH range from 5.0 to 95.0%. Other features in this mode include: automatic field calibration, a humidity resolution of 0.1% and 1% and analog humidity\/RTD outputs.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eIn the dew point\/temperature mode, \u003cspan style=\"font-size: small;\"\u003etemperature \/ humidity logger\u003c\/span\u003e calculates the dew point from the relative humidity and temperature data, and displays it and the temperature (RTD) on the LCD. A dew point range of -94° to 158°F (-70° to 70°C) is available with wide-range humidity probe 637-0050, a dew point range of -58° to 122°F (-50° to 50°C) is available with general-purpose humidity probe 637-0052.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eThe \u003cspan style=\"font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e is housed in a molded ABS plastic housing and has a membrane keypad. Dual LCD shows scale and mode selected. Two AA batteries (included) provide 50 hours of continuous operation in standby mode. Purchase optional battery pack for up to 300 hours of continuous use. (We recommend using the optional AC wall mount power supply 691-9050 where line power is available). Order the L-shaped mounting bracket to attach either RH probe to the logger. See below to order software, logger kits, probes, and accessories.\u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003eTemperature \/ Humidity Logger Specifications:\u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eWITH THERMOCOUPLE PROBES\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eTemperature ranges\u003c\/strong\u003e:\u003cbr\u003e  \u003cstrong\u003eJ\u003c\/strong\u003e: -310 to 1832°F (-190 to 1000°C)\u003cbr\u003e  \u003cstrong\u003eK\u003c\/strong\u003e: -418 to 2507°F (-250 to 1375°C)\u003cbr\u003e  \u003cstrong\u003eT\u003c\/strong\u003e: -418 to 752°F (-250 to 400°C)\u003cbr\u003e\u003cstrong\u003eTemperature resolution\u003c\/strong\u003e: 0.1\/1° F or °C (switchable); autoranging to 1° above 999.9°.\u003cbr\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e: ±0.1% of reading or ±0.7°F (±0.4°C) above -238°F (-150°C) ±2°F (±1°C) below -238°F (-150°C)\u003cbr\u003e\u003cstrong\u003eDifferential (DT) accuracy\u003c\/strong\u003e: ±0.5°F (±0.3°C)\u003cbr\u003e\u003cstrong\u003eProbes\u003c\/strong\u003e: one or two type J, K, or T thermocouple probes (sold separately)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eWITH RELATIVE HUMIDITY\/TEMPERATURE PROBE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eRH ranges\u003c\/strong\u003e:\u003cbr\u003e\u003cstrong\u003e637-0050\u003c\/strong\u003e 0.0 to 100.0% RH within -22 to 158°F (-30 to 70°C) temperature range\u003cbr\u003e\u003cstrong\u003e637-0052\u003c\/strong\u003e 5.0 to 95.0% RH within 32 to 122°F (0 to 50°C) temperature range\u003cbr\u003e\u003cstrong\u003eRH resolution\u003c\/strong\u003e: 0.1% \/ 1% (selectable)\u003cbr\u003e\u003cstrong\u003eRH accuracy\u003c\/strong\u003e:\u003cbr\u003e\u003cstrong\u003e637-0050\u003c\/strong\u003e ±2% RH from 10.0 to 96.0% RH; ±3% outside these limits\u003cbr\u003e\u003cstrong\u003e637-0052\u003c\/strong\u003e ±RH from 10.0 to 90.0% RH; ±3% outside these limits\u003cbr\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e: -32 to 212°F (0 to 100°C)\u003cbr\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e: ±2.7°F (±1.5°C)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eGENERAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: dual LCD - one 4-digit, 3\/8\"H and one 5-character alphanumeric, 3\/16\"H\u003cbr\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e: 0.0 to 1.0V analog output of temperature and humidity; bidirectional RS-232-C\u003cbr\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e: Stores 850 pairs of readings for recall\u003cbr\u003e\u003cstrong\u003ePower\u003c\/strong\u003e: two AA batteries (included), optional battery pack, or optional AC adapter\u003cbr\u003e\u003cstrong\u003eBattery life\u003c\/strong\u003e: up to 50 hours of continuous operation in standby mode (with AA batteries) or up to 300 hours (with optional battery pack)\u003cbr\u003e\u003cstrong\u003eLow battery indication\u003c\/strong\u003e: yes\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 6 1\/2\"Wx3 1\/2\"Hx7 3\/4\"D\u003cbr\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e: 3 lbs (1.4 kg)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","published_at":"2019-10-24T10:48:21-04:00","created_at":"2019-10-24T10:48:22-04:00","vendor":"HCS","type":"","tags":["Controllers\/Sensors","HCS","Process Heat","Tools"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986933469261,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCSTH-L","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS Temperature \/ Humidity Logger","public_title":null,"options":["Default Title"],"price":0,"weight":907,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.24.22_PM.png?v=1572456509"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.24.22_PM.png?v=1572456509","options":["Title"],"media":[{"alt":"HCS Temperature \/ Humidity Logger","id":5533334339661,"position":1,"preview_image":{"aspect_ratio":1.524,"height":294,"width":448,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.24.22_PM.png?v=1572456509"},"aspect_ratio":1.524,"height":294,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.24.22_PM.png?v=1572456509","width":448}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMeasure temperature and humidity with one instrument\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAccepts two type J, K,or T thermocouple probes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStandby mode conserves batteries while logging data\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eOptional software for bi-directional\u003cspan style=\"font-family: verdana, geneva;\"\u003e RS-232 communications\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStores 850 pairs of measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eUse the benchtop \u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003e almost anywhere temperature and humidity needs to be monitored - laboratories, museums, art galleries, warehouses, protected outdoor environments, and more! The logger operates in three modes: two-channel temperature, humidity\/temperature, and dew point\/temperature.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eThis compact, portable \u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small;\"\u003e is packed with features. Non-volatile memory stores setup conditions (interval time or total logging time), thermocouple probe type, logged\/stored parameters, and peak\/valley values for each mode. Serial input\/output allows for printer and computer compatibility, optional data analysis software and serial printer available.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eMeasure and display either differential (DT) temperature or dual temperature simultaneously in the two-channel temperature mode. The \u003cspan style=\"font-size: small;\"\u003etemperature \/ humidity logger\u003c\/span\u003e accepts one or two type J, K, or T thermocouple probes with ANSI miniconnectors. Features in this mode include autocalibration of probe, selectable °F or °C scale, selectable 0.1%\/1° resolution up to 999.9° (1° above 999.9°), dual analog temperature output, and accuracy of ±0.1% of reading.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eMeasure and display both relative humidity and temperature (RTD) in the humidity\/temperature mode. Use one of two interchangeable relative humidity\/temperature probes. Wide-range probe 637-0050 has a compensated RH range from 0 to 100%. General-purpose probe 637-0052 has a compensated RH range from 5.0 to 95.0%. Other features in this mode include: automatic field calibration, a humidity resolution of 0.1% and 1% and analog humidity\/RTD outputs.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eIn the dew point\/temperature mode, \u003cspan style=\"font-size: small;\"\u003etemperature \/ humidity logger\u003c\/span\u003e calculates the dew point from the relative humidity and temperature data, and displays it and the temperature (RTD) on the LCD. A dew point range of -94° to 158°F (-70° to 70°C) is available with wide-range humidity probe 637-0050, a dew point range of -58° to 122°F (-50° to 50°C) is available with general-purpose humidity probe 637-0052.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003eThe \u003cspan style=\"font-size: small;\"\u003eTemperature\/Humidity Logger\u003c\/span\u003e is housed in a molded ABS plastic housing and has a membrane keypad. Dual LCD shows scale and mode selected. Two AA batteries (included) provide 50 hours of continuous operation in standby mode. Purchase optional battery pack for up to 300 hours of continuous use. (We recommend using the optional AC wall mount power supply 691-9050 where line power is available). Order the L-shaped mounting bracket to attach either RH probe to the logger. See below to order software, logger kits, probes, and accessories.\u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003eTemperature \/ Humidity Logger Specifications:\u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eWITH THERMOCOUPLE PROBES\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eTemperature ranges\u003c\/strong\u003e:\u003cbr\u003e  \u003cstrong\u003eJ\u003c\/strong\u003e: -310 to 1832°F (-190 to 1000°C)\u003cbr\u003e  \u003cstrong\u003eK\u003c\/strong\u003e: -418 to 2507°F (-250 to 1375°C)\u003cbr\u003e  \u003cstrong\u003eT\u003c\/strong\u003e: -418 to 752°F (-250 to 400°C)\u003cbr\u003e\u003cstrong\u003eTemperature resolution\u003c\/strong\u003e: 0.1\/1° F or °C (switchable); autoranging to 1° above 999.9°.\u003cbr\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e: ±0.1% of reading or ±0.7°F (±0.4°C) above -238°F (-150°C) ±2°F (±1°C) below -238°F (-150°C)\u003cbr\u003e\u003cstrong\u003eDifferential (DT) accuracy\u003c\/strong\u003e: ±0.5°F (±0.3°C)\u003cbr\u003e\u003cstrong\u003eProbes\u003c\/strong\u003e: one or two type J, K, or T thermocouple probes (sold separately)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eWITH RELATIVE HUMIDITY\/TEMPERATURE PROBE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eRH ranges\u003c\/strong\u003e:\u003cbr\u003e\u003cstrong\u003e637-0050\u003c\/strong\u003e 0.0 to 100.0% RH within -22 to 158°F (-30 to 70°C) temperature range\u003cbr\u003e\u003cstrong\u003e637-0052\u003c\/strong\u003e 5.0 to 95.0% RH within 32 to 122°F (0 to 50°C) temperature range\u003cbr\u003e\u003cstrong\u003eRH resolution\u003c\/strong\u003e: 0.1% \/ 1% (selectable)\u003cbr\u003e\u003cstrong\u003eRH accuracy\u003c\/strong\u003e:\u003cbr\u003e\u003cstrong\u003e637-0050\u003c\/strong\u003e ±2% RH from 10.0 to 96.0% RH; ±3% outside these limits\u003cbr\u003e\u003cstrong\u003e637-0052\u003c\/strong\u003e ±RH from 10.0 to 90.0% RH; ±3% outside these limits\u003cbr\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e: -32 to 212°F (0 to 100°C)\u003cbr\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e: ±2.7°F (±1.5°C)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, geneva; font-size: small; color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eGENERAL SPECIFICATIONS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: dual LCD - one 4-digit, 3\/8\"H and one 5-character alphanumeric, 3\/16\"H\u003cbr\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e: 0.0 to 1.0V analog output of temperature and humidity; bidirectional RS-232-C\u003cbr\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e: Stores 850 pairs of readings for recall\u003cbr\u003e\u003cstrong\u003ePower\u003c\/strong\u003e: two AA batteries (included), optional battery pack, or optional AC adapter\u003cbr\u003e\u003cstrong\u003eBattery life\u003c\/strong\u003e: up to 50 hours of continuous operation in standby mode (with AA batteries) or up to 300 hours (with optional battery pack)\u003cbr\u003e\u003cstrong\u003eLow battery indication\u003c\/strong\u003e: yes\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 6 1\/2\"Wx3 1\/2\"Hx7 3\/4\"D\u003cbr\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e: 3 lbs (1.4 kg)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e"}

HCS Temperature / Humidity Logger

Product Description
  • Measure temperature and humidity with one instrument
  • Accepts two type J, K,or T thermocouple probes
  • Standby mode conserves batteries while logging data
  • Optional software for bi-directional RS-232 communications
  • Stores 850 pairs of measurements

Use the benchtop Temperature/Humidity Logger almost anywhere temperature and humidity needs to be monitored - laboratories, museums, art galleries, warehouses, protected outdoor environments, and more! The logger operates in three modes: two-channel temperature, humidity/temperature, and dew point/temperature.

This compact, portable Temperature/Humidity Logger is packed with features. Non-volatile memory stores setup conditions (interval time or total logging time), thermocouple probe type, logged/stored parameters, and peak/valley values for each mode. Serial input/output allows for printer and computer compatibility, optional data analysis software and serial printer available.

Measure and display either differential (DT) temperature or dual temperature simultaneously in the two-channel temperature mode. The temperature / humidity logger accepts one or two type J, K, or T thermocouple probes with ANSI miniconnectors. Features in this mode include autocalibration of probe, selectable °F or °C scale, selectable 0.1%/1° resolution up to 999.9° (1° above 999.9°), dual analog temperature output, and accuracy of ±0.1% of reading.

Measure and display both relative humidity and temperature (RTD) in the humidity/temperature mode. Use one of two interchangeable relative humidity/temperature probes. Wide-range probe 637-0050 has a compensated RH range from 0 to 100%. General-purpose probe 637-0052 has a compensated RH range from 5.0 to 95.0%. Other features in this mode include: automatic field calibration, a humidity resolution of 0.1% and 1% and analog humidity/RTD outputs.

In the dew point/temperature mode, temperature / humidity logger calculates the dew point from the relative humidity and temperature data, and displays it and the temperature (RTD) on the LCD. A dew point range of -94° to 158°F (-70° to 70°C) is available with wide-range humidity probe 637-0050, a dew point range of -58° to 122°F (-50° to 50°C) is available with general-purpose humidity probe 637-0052.

The Temperature/Humidity Logger is housed in a molded ABS plastic housing and has a membrane keypad. Dual LCD shows scale and mode selected. Two AA batteries (included) provide 50 hours of continuous operation in standby mode. Purchase optional battery pack for up to 300 hours of continuous use. (We recommend using the optional AC wall mount power supply 691-9050 where line power is available). Order the L-shaped mounting bracket to attach either RH probe to the logger. See below to order software, logger kits, probes, and accessories.

Temperature / Humidity Logger Specifications:

WITH THERMOCOUPLE PROBES:
Temperature ranges:
  J: -310 to 1832°F (-190 to 1000°C)
  K: -418 to 2507°F (-250 to 1375°C)
  T: -418 to 752°F (-250 to 400°C)
Temperature resolution: 0.1/1° F or °C (switchable); autoranging to 1° above 999.9°.
Temperature accuracy: ±0.1% of reading or ±0.7°F (±0.4°C) above -238°F (-150°C) ±2°F (±1°C) below -238°F (-150°C)
Differential (DT) accuracy: ±0.5°F (±0.3°C)
Probes: one or two type J, K, or T thermocouple probes (sold separately)

WITH RELATIVE HUMIDITY/TEMPERATURE PROBE:
RH ranges:
637-0050 0.0 to 100.0% RH within -22 to 158°F (-30 to 70°C) temperature range
637-0052 5.0 to 95.0% RH within 32 to 122°F (0 to 50°C) temperature range
RH resolution: 0.1% / 1% (selectable)
RH accuracy:
637-0050 ±2% RH from 10.0 to 96.0% RH; ±3% outside these limits
637-0052 ±RH from 10.0 to 90.0% RH; ±3% outside these limits
Temperature range: -32 to 212°F (0 to 100°C)
Temperature accuracy: ±2.7°F (±1.5°C)

GENERAL SPECIFICATIONS:
Display: dual LCD - one 4-digit, 3/8"H and one 5-character alphanumeric, 3/16"H
Output: 0.0 to 1.0V analog output of temperature and humidity; bidirectional RS-232-C
Memory: Stores 850 pairs of readings for recall
Power: two AA batteries (included), optional battery pack, or optional AC adapter
Battery life: up to 50 hours of continuous operation in standby mode (with AA batteries) or up to 300 hours (with optional battery pack)
Low battery indication: yes
Dimensions: 6 1/2"Wx3 1/2"Hx7 3/4"D
Shipping weight: 3 lbs (1.4 kg)