{"id":4306010079309,"title":"HCS Field Selectable Input\/Output Controller","handle":"products-field-selectable-inputoutput-controller","description":"\u003cp\u003e\u003cspan\u003eField Selectable Input\/Output Controller features universal field selectable outputs for the main control output. The main control output can be selected from a relay contact, a voltage pulse, or a 4 to 20 mAmp output.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eField Selectable Input\/Output Controller also excepts 44 types of thermocouple, RTD, DC voltage and DC current. In addition these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. The Heater break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. The loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR. \u003c\/span\u003e\u003c\/p\u003e\u003ch2 style=\"text-align: left;\"\u003eField Selectable Input\/Output Controller Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eStandard universal inputs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eField selectable outputs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eEasy set up and programming fuzzy logic on\/off\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeater break alarm for monitoring multiple parallel heaters\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eLoop break alarm for heater breaks\/shorted sensors or relays\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAlarm hold and alarm delay functions 2 alarms field configurable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eDual set point local or remote setable and ramp to setpoint\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"text-align: left;\"\u003eField Selectable Input\/Output Controller Specifications:\u003c\/h2\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINPUT \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eThermocouple\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003eType K, J, T, E, R, B, N, S, L, \u0026amp; U\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRTD\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003ePT 100, JPT 100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eMillivolts\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-10mV, 0-100mV, 0-1V, 0-5V, 0-10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e4-20mA DC 0-20mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDefault Setting\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e-300 to 1500F J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOUTPUT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRelay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250VAC, 3A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePulsed Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 0\/12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-20mA DC, 4-20mA DC, max 600 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eContinuous Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-5V, 0-1 OV, 1-5V, DC Load Res \u0026gt; 1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCONTROL METHOD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarm Set Point\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eP, PI, PD, PID with fuzzy, on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eError Output\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eOutput errors mean T\/C, RTD input disconnection, A\/D convertor error and setting data error.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e+\/-0.3% FS+1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSampling Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0.5 second (500ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eEXTERNAL DIMENSIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 48 x 48 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D400\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 96 x 48 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D900\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e96 x 96 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e90-264 VAC - 50\/60 Hz 6VA 100V, 9VA 200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOPTIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eRS-485 (2 wire type) RS-422A (4-wire type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 150, 300, 1200, 2400, 4800, 9600 bps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAddress\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1 to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eParit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eWith or without, even or odd in case of with\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eStop Bit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1 or 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eData Bit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e7 or 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eExternal contact signal Off (SP1), On (SP2).\u003c\/p\u003e\u003cp\u003eRetransmission output: 4-20mA DC, 0-20mA DC, 1-5VDC, 0-1 OVDC, 0-5VDC.\u003c\/p\u003e","published_at":"2019-10-24T10:48:03-04:00","created_at":"2019-10-24T10:48:04-04:00","vendor":"HCS","type":"","tags":["Controllers\/Sensors","HCS","Process Heat","Tools"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986930520141,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCSFSIO-C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS Field Selectable Input\/Output Controller","public_title":null,"options":["Default Title"],"price":0,"weight":227,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-08-15_at_2.09.55_PM.png?v=1572456492"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-08-15_at_2.09.55_PM.png?v=1572456492","options":["Title"],"media":[{"alt":"HCS Field Selectable Input\/Output Controller","id":5533331783757,"position":1,"preview_image":{"aspect_ratio":0.853,"height":238,"width":203,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-08-15_at_2.09.55_PM.png?v=1572456492"},"aspect_ratio":0.853,"height":238,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-08-15_at_2.09.55_PM.png?v=1572456492","width":203}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eField Selectable Input\/Output Controller features universal field selectable outputs for the main control output. The main control output can be selected from a relay contact, a voltage pulse, or a 4 to 20 mAmp output.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eField Selectable Input\/Output Controller also excepts 44 types of thermocouple, RTD, DC voltage and DC current. In addition these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. The Heater break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. The loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR. \u003c\/span\u003e\u003c\/p\u003e\u003ch2 style=\"text-align: left;\"\u003eField Selectable Input\/Output Controller Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eStandard universal inputs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eField selectable outputs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eEasy set up and programming fuzzy logic on\/off\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eHeater break alarm for monitoring multiple parallel heaters\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eLoop break alarm for heater breaks\/shorted sensors or relays\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAlarm hold and alarm delay functions 2 alarms field configurable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eDual set point local or remote setable and ramp to setpoint\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"text-align: left;\"\u003eField Selectable Input\/Output Controller Specifications:\u003c\/h2\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINPUT \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eThermocouple\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003eType K, J, T, E, R, B, N, S, L, \u0026amp; U\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRTD\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003ePT 100, JPT 100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eMillivolts\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-10mV, 0-100mV, 0-1V, 0-5V, 0-10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e4-20mA DC 0-20mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDefault Setting\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e-300 to 1500F J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOUTPUT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRelay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250VAC, 3A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePulsed Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 0\/12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-20mA DC, 4-20mA DC, max 600 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eContinuous Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0-5V, 0-1 OV, 1-5V, DC Load Res \u0026gt; 1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCONTROL METHOD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarm Set Point\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eP, PI, PD, PID with fuzzy, on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eError Output\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eOutput errors mean T\/C, RTD input disconnection, A\/D convertor error and setting data error.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e+\/-0.3% FS+1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSampling Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0.5 second (500ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eEXTERNAL DIMENSIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 48 x 48 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D400\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 96 x 48 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eREX - D900\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e96 x 96 x 100-mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e90-264 VAC - 50\/60 Hz 6VA 100V, 9VA 200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOPTIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eRS-485 (2 wire type) RS-422A (4-wire type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 150, 300, 1200, 2400, 4800, 9600 bps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAddress\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1 to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eParit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003eWith or without, even or odd in case of with\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eStop Bit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1 or 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eData Bit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e7 or 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eExternal contact signal Off (SP1), On (SP2).\u003c\/p\u003e\u003cp\u003eRetransmission output: 4-20mA DC, 0-20mA DC, 1-5VDC, 0-1 OVDC, 0-5VDC.\u003c\/p\u003e"}

HCS Field Selectable Input/Output Controller

Product Description

Field Selectable Input/Output Controller features universal field selectable outputs for the main control output. The main control output can be selected from a relay contact, a voltage pulse, or a 4 to 20 mAmp output.

Field Selectable Input/Output Controller also excepts 44 types of thermocouple, RTD, DC voltage and DC current. In addition these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. The Heater break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. The loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR. 

Field Selectable Input/Output Controller Features:

  • Standard universal inputs 
  • Field selectable outputs 
  • Easy set up and programming fuzzy logic on/off 
  • Heater break alarm for monitoring multiple parallel heaters 
  • Loop break alarm for heater breaks/shorted sensors or relays 
  • Alarm hold and alarm delay functions 2 alarms field configurable 
  • Dual set point local or remote setable and ramp to setpoint

Field Selectable Input/Output Controller Specifications:

INPUT 
Thermocouple Type K, J, T, E, R, B, N, S, L, & U
RTD PT 100, JPT 100
Millivolts 0-10mV, 0-100mV, 0-1V, 0-5V, 0-10V
Current 4-20mA DC 0-20mA DC
Default Setting -300 to 1500F J
OUTPUT
Relay 250VAC, 3A resistive load
Pulsed Voltage  0/12VDC
Current 0-20mA DC, 4-20mA DC, max 600 ohms
Continuous Voltage 0-5V, 0-1 OV, 1-5V, DC Load Res > 1 K
CONTROL METHOD
Alarm Set Point P, PI, PD, PID with fuzzy, on/off
Error Output Output errors mean T/C, RTD input disconnection, A/D convertor error and setting data error.
Accuracy +/-0.3% FS+1 digit
Sampling Time 0.5 second (500ms)
EXTERNAL DIMENSIONS
REX - D100  48 x 48 x 100-mm.
REX - D400  96 x 48 x 100-mm.
REX - D900 96 x 96 x 100-mm.
Power Supply 90-264 VAC - 50/60 Hz 6VA 100V, 9VA 200V
OPTIONS
Digital Communication RS-485 (2 wire type) RS-422A (4-wire type)
Communication Speed  150, 300, 1200, 2400, 4800, 9600 bps.
Address 1 to 16
Parit With or without, even or odd in case of with
Stop Bit 1 or 2
Data Bit 7 or 8

External contact signal Off (SP1), On (SP2).

Retransmission output: 4-20mA DC, 0-20mA DC, 1-5VDC, 0-1 OVDC, 0-5VDC.