{"id":4306011193421,"title":"HCS PID Temperature Controllers","handle":"products-hcs-pid-temperature-controllers","description":"\u003cp\u003ePID Temperature Controllers feature dual displays \u0026amp; selectable inputs. These PID Temperature Controllers are easy to operate and the out can be ordered for a relay contact, a voltage pulse, or a 4 to 20 mAmp output. \u003cbr\u003e\u003cbr\u003ePID Temperature Controllers also accepts various inputs from f thermocouples, RTD, DC voltage and DC current. In addition, these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. \u003cbr\u003e\u003cbr\u003eThe Heater Break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. \u003cbr\u003e\u003cbr\u003eThe loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR.\u003c\/p\u003e\u003ch2\u003ePID Temperature Controllers Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStandard inputs thermocouple, RTD \u003c\/li\u003e\n\u003cli\u003eHeat \/ Cool action \u003c\/li\u003e\n\u003cli\u003eRelay, Triac, DC voltage pulse or current output \u003c\/li\u003e\n\u003cli\u003eHeater Break alarm for monitoring multiple parallel heaters \u003c\/li\u003e\n\u003cli\u003eLoop break alarm for heater breaks\/shorted sensors or relays\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePID Temperature Controllers Specifications:\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003cbr\u003eThermocouple. . . . . . . . .K,J,R,S,B,T,L,N,E,PLII W5Re\/W26Re.\u003cbr\u003eRTD. . . . . . . . . . . . . (PIIOO, JPll OO) -199.9-649.0C -199.9-999 OF\u003cbr\u003eDC voltage. . . . . . . . . .(0-5V,1-5V) 0.0-100% (fixed)\u003cbr\u003eDC current. . . . . . . . . .(0-20mA, 4-20mA) 0.0-100% (fixed)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl Output\u003c\/strong\u003e\u003cbr\u003eRelay. . . . . . . . . . . . 25OVAC, 3A Form A or Form C contact\u003cbr\u003eVoltage pulse. . . . . . . . 0 \/ l2VDC, load resistance more than 600 Ohms\u003cbr\u003eCurrent. . . . . . . . . . . 4-20mA DC load resistance less tham 600 Ohms\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHBA Alarm\u003c\/strong\u003e\u003cbr\u003eInput. . . . . . . . . . . . Output signal from CT\u003cbr\u003eRange. . . . . . . . . . . . 0-30A or 0-100A\u003cbr\u003eAccuracy. . . . . . . . . . .+\/-0.5% or 2A, whichever is larger\u003cbr\u003eRelay output. . . . . . . . .25OVAC, 1 A contact\u003cbr\u003eHeating load draw:. . . . . .30 or 100 amps must be specified\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLBA Alarm\u003c\/strong\u003e\u003cbr\u003eSetting range 0.1-200.0 minutes.\u003cbr\u003eRelay output 25OVAC,1 A contact\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl Action\u003c\/strong\u003e\u003cbr\u003ea) PID action with autotuning\u003cbr\u003eb) Heat \/ cool PID action with autotuning (not available on REX-C100)\u003cbr\u003eHeating proportional band (P). 1-100% of input range.\u003cbr\u003eCooling proportional band. . .1-1000% of heating proportional band\u003cbr\u003eIntegral (1). . . . . . . . . .1-3600 seconds\u003cbr\u003eDerivative (D). . . . . . . . .1-3600 seconds\u003cbr\u003eARW. . . . . . . . . . . . . .1-100% of proportional band\u003cbr\u003eHeating cycle. . . . . . . . .1-100 seconds\u003cbr\u003eCooling cycle. . . . . . . . .1-100 seconds\u003c\/p\u003e\u003cp\u003eSampling Rate 0.5 seconds\u003cbr\u003eSetting Accuracy Thermocouple input.+\/- (0.5% of SV + 1 digit)\u003c\/p\u003e\u003cp\u003eRTD input. . . . . . . . . . . +\/- (0.5% of SV + 1 digit) 0.8C (1.6F)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExternal Dimensions\u003c\/strong\u003e\u003cbr\u003eREX-C100. . . . . . . . . . . .48 x 48 x 100mm\u003cbr\u003eREX-C400. . . . . . . . . . . .96 x 48 x 100mm\u003cbr\u003eREX-C410. . . . . . . . . . . .48 x 96 x 100mm\u003cbr\u003eREX-C700. . . . . . . . . . . .96 x 96 x 100mm\u003c\/p\u003e\u003cp\u003eSupply Voltage 90-264 VAC (50 \/ 60 HZ)\u003c\/p\u003e","published_at":"2019-10-24T10:48:16-04:00","created_at":"2019-10-24T10:48:17-04:00","vendor":"HCS","type":"","tags":["Controllers\/Sensors","HCS","Process Heat","Tools"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986932879437,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCSPIDT-C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS PID Temperature Controllers","public_title":null,"options":["Default Title"],"price":0,"weight":227,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.48.37_PM.png?v=1572456504"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.48.37_PM.png?v=1572456504","options":["Title"],"media":[{"alt":"HCS PID Temperature Controllers","id":5533333520461,"position":1,"preview_image":{"aspect_ratio":2.676,"height":170,"width":455,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.48.37_PM.png?v=1572456504"},"aspect_ratio":2.676,"height":170,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.48.37_PM.png?v=1572456504","width":455}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003ePID Temperature Controllers feature dual displays \u0026amp; selectable inputs. These PID Temperature Controllers are easy to operate and the out can be ordered for a relay contact, a voltage pulse, or a 4 to 20 mAmp output. \u003cbr\u003e\u003cbr\u003ePID Temperature Controllers also accepts various inputs from f thermocouples, RTD, DC voltage and DC current. In addition, these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. \u003cbr\u003e\u003cbr\u003eThe Heater Break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. \u003cbr\u003e\u003cbr\u003eThe loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR.\u003c\/p\u003e\u003ch2\u003ePID Temperature Controllers Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStandard inputs thermocouple, RTD \u003c\/li\u003e\n\u003cli\u003eHeat \/ Cool action \u003c\/li\u003e\n\u003cli\u003eRelay, Triac, DC voltage pulse or current output \u003c\/li\u003e\n\u003cli\u003eHeater Break alarm for monitoring multiple parallel heaters \u003c\/li\u003e\n\u003cli\u003eLoop break alarm for heater breaks\/shorted sensors or relays\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePID Temperature Controllers Specifications:\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003cbr\u003eThermocouple. . . . . . . . .K,J,R,S,B,T,L,N,E,PLII W5Re\/W26Re.\u003cbr\u003eRTD. . . . . . . . . . . . . (PIIOO, JPll OO) -199.9-649.0C -199.9-999 OF\u003cbr\u003eDC voltage. . . . . . . . . .(0-5V,1-5V) 0.0-100% (fixed)\u003cbr\u003eDC current. . . . . . . . . .(0-20mA, 4-20mA) 0.0-100% (fixed)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl Output\u003c\/strong\u003e\u003cbr\u003eRelay. . . . . . . . . . . . 25OVAC, 3A Form A or Form C contact\u003cbr\u003eVoltage pulse. . . . . . . . 0 \/ l2VDC, load resistance more than 600 Ohms\u003cbr\u003eCurrent. . . . . . . . . . . 4-20mA DC load resistance less tham 600 Ohms\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHBA Alarm\u003c\/strong\u003e\u003cbr\u003eInput. . . . . . . . . . . . Output signal from CT\u003cbr\u003eRange. . . . . . . . . . . . 0-30A or 0-100A\u003cbr\u003eAccuracy. . . . . . . . . . .+\/-0.5% or 2A, whichever is larger\u003cbr\u003eRelay output. . . . . . . . .25OVAC, 1 A contact\u003cbr\u003eHeating load draw:. . . . . .30 or 100 amps must be specified\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLBA Alarm\u003c\/strong\u003e\u003cbr\u003eSetting range 0.1-200.0 minutes.\u003cbr\u003eRelay output 25OVAC,1 A contact\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl Action\u003c\/strong\u003e\u003cbr\u003ea) PID action with autotuning\u003cbr\u003eb) Heat \/ cool PID action with autotuning (not available on REX-C100)\u003cbr\u003eHeating proportional band (P). 1-100% of input range.\u003cbr\u003eCooling proportional band. . .1-1000% of heating proportional band\u003cbr\u003eIntegral (1). . . . . . . . . .1-3600 seconds\u003cbr\u003eDerivative (D). . . . . . . . .1-3600 seconds\u003cbr\u003eARW. . . . . . . . . . . . . .1-100% of proportional band\u003cbr\u003eHeating cycle. . . . . . . . .1-100 seconds\u003cbr\u003eCooling cycle. . . . . . . . .1-100 seconds\u003c\/p\u003e\u003cp\u003eSampling Rate 0.5 seconds\u003cbr\u003eSetting Accuracy Thermocouple input.+\/- (0.5% of SV + 1 digit)\u003c\/p\u003e\u003cp\u003eRTD input. . . . . . . . . . . +\/- (0.5% of SV + 1 digit) 0.8C (1.6F)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExternal Dimensions\u003c\/strong\u003e\u003cbr\u003eREX-C100. . . . . . . . . . . .48 x 48 x 100mm\u003cbr\u003eREX-C400. . . . . . . . . . . .96 x 48 x 100mm\u003cbr\u003eREX-C410. . . . . . . . . . . .48 x 96 x 100mm\u003cbr\u003eREX-C700. . . . . . . . . . . .96 x 96 x 100mm\u003c\/p\u003e\u003cp\u003eSupply Voltage 90-264 VAC (50 \/ 60 HZ)\u003c\/p\u003e"}