{"id":4306011816013,"title":"HCS Temperature Monitoring System 12-Channel Scanning","handle":"products-hcs-barnant-temperature-monitoring-systems","description":"\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eStore and recall up to 4680 sets of readings with time and date\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eAutomatically or manually display, record and output temperature readings\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eField calibrate each probe separately - achieve accuracies of ± 0.1% of reading!\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eBidirectional RS-232 for setup or PC data logging\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIncludes a real-time clock, nonvolatile memory, and parallel printer output (benchtop only)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eImmune to RF interference\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOur Temperature Monitoring System is ideal when simultaneous monitoring of temperatures during different process steps or phases is critical, these new 12-channel scanning thermometers. \u003cbr\u003e\u003cbr\u003eThe wall mount Temperature Monitoring System is ideal for permanent installation and continuous monitoring of your processes. \u003cbr\u003e\u003cbr\u003eThe benchtop Temperature Monitoring System accepts most any power source giving you great flexibility as to where and when it may be used. Both models function as a data logger - store data in the non-volatile memory and later download to your printer or PC. Link both models in series to expand the number of channels you can scan. Each of the 12 thermocouple inputs is programmable to scan from every four seconds to hourly.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003eBENCHTOP THERMOMETER\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eParallel printer connection allows you to connect the thermometer to a printer - make a hard copy of your data as a permanent record\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003ePower unit with included 115 VAC or 230 VAC adapter or any 10 to 25 VDC or 7 to 20 VAC 500 mA power supply. (user supplied)\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eAccepts thermocouple probes with miniconnectors for quick and easy probe changes.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eWALL-MOUNT THERMOMETER\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eUse high and low relays for on\/off control; relays are rated at 250 VAC 2A or 2A at 30 VDC resistive.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eFeatures an easy-to-view drip proof housing with all wire connections on the bottom.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003ePower the unit with 100-240 VAC, 50\/60Hz.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eINSTRUMENT FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eScan and log up to 12 thermocouple inputs from any combination of J, K, T, E, N, B, R, and S thermocouple probes.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eThermocouple type is individually selectable per channel.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eDatalogging feature automatically stores up to 4680 sets of readings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eDownload readings or stored data to your computer.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eLink up to 8 units together to expand channel capacity.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eSequentially captures temperature data, allowing you to monitor and record process variations - ideal for statistical process control.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eEasy-to-use front panel MENU key lets you program data logging and print intervals, scan rate, date and time, temperature scale (°F, °C, K, °R), resolution (0.1 or 1°), channels displayed, thermocouple type, and data output parameters.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eEach channel features HOLD, STORE, MAX and MIN (measures maximum and minimum values), RECALL and AVERAGE buttons.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eCalibrate each channel separately at either one or two points to minimize probe offset. Parameter setup and calibration offsets are stored in nonvolatile memory.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eEach scanner is factory calibrated to NIST-traceable standards.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eMULTIPLE SAFETY FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eMENU key lets you select high or low alarm set points for each channel. Easily enable or disable the audible alarm and set alarm hysteresis; program for manual or automatic alarm reset.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eThermocouple inputs are electrically isolated from each other and from data outputs - provides safe and accurate measurements even when probes are exposed to various electrical conditions.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003ePHYSICAL FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eLarge 3\/4\" high, 14-segment, 12-character alphanumeric LCD indicates channel number or name, temperature reading, and temperature units.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIndicator light warns you of open probes or out-of-range readings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eBenchtop models accept thermocouple probes with ANSI miniconnectors for quick hookup and changes.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eWall-mount models accept thermocouple probes with stripped ends.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eCOMPUTER\/PRINTER CAPABILITIES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eUse printing function to send current readings directly to your computer and printer at chosen intervals.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eVary data logging and printing intervals from 4 seconds to 99 minutes, 59 seconds.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eFeatures RS-232 (for both units), and parallel printer output of date and time (benchtop only), channel number and name, and temperature readings in a tabular format.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIncludes RS-232 cable. Parallel printer cable is not included (sold separately)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eRemember to order the proper probes for your application. Barnant offers a wide variety of thermocouple probes (J, K, T, E, N, R, S, and B) wire, connectors and other accessories to ensure your temperature scanner will provide the ultimate function and performance. \u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003eTemperature Monitoring System Specifications: \u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eRanges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e \u003cstrong\u003eJ\u003c\/strong\u003e: -200 to 1000°C (-392 to 1832°F)\u003cbr\u003e \u003cstrong\u003eK\u003c\/strong\u003e: -250 to 1372°C (-418 to 2501°F)\u003cbr\u003e \u003cstrong\u003eT\u003c\/strong\u003e: -250 to 400°C (-418 to 752°F)\u003cbr\u003e \u003cstrong\u003eE\u003c\/strong\u003e: -250 to 1000°C (-418 to 1832°F)\u003cbr\u003e \u003cstrong\u003eN\u003c\/strong\u003e: -250 to 1300°C (-418 to 2372°F)\u003cbr\u003e \u003cstrong\u003eR\u003c\/strong\u003e: 0 to1768°C (32 to 3214°F)\u003cbr\u003e \u003cstrong\u003eS\u003c\/strong\u003e: 0 to 1768°C (32 to 3214°F)\u003cbr\u003e \u003cstrong\u003eB\u003c\/strong\u003e: 200 to 1800°C (392 to 3272°F)\u003cbr\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 0.1°\/1° selectable up to 999.9°, 1° above 1000°; autorange to 1° below -150°C\u003cbr\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: J, K, T, E, N: ±0.1% of rdg., ±0.5°C (±0.8°F) above -150°C; ±0.25% of rdg., ±1°C (±2°F) below -150°C\u003cbr\u003eR, S, B: ±0.1% of reading, ±2°C (±4°F)\u003cbr\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: 12 character alphanumeric LCD\u003cbr\u003e\u003cstrong\u003eDisplay update rate\u003c\/strong\u003e: 3 sec\/channel\u003cbr\u003e\u003cstrong\u003eScan rate\u003c\/strong\u003e: From 4 sec\/12 channels to 99 min 59 sec\/12 channels\u003cbr\u003e\u003cstrong\u003eAlarm output\u003c\/strong\u003e: (Wall-mount units only) SPDT high\/low relays are rated at 250 VAC 2A or 2A at 30 VDC resistive.\u003cbr\u003e\u003cstrong\u003eDigital output\u003c\/strong\u003e: Both models: RS-232, ASCII format, baud rate 19.2 K, RJ11connector;\u003cbr\u003eBenchtop unit only: Centronics parallel printer output; DB25F connector\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Benchtop: 7 1\/2\"L x 10 1\/2\"W x 3 1\/2\"H\u003cbr\u003eWall-mount: 5 1\/2\"L x 11 1\/4\"W x 8 1\/2\"H\u003cbr\u003e\u003cstrong\u003eShpg wt\u003c\/strong\u003e: Benchtop: 3 lb (1.4 kg)\u003cbr\u003eWall-mount: 4 lb (1.8 kg)\u003cbr\u003e\u003cstrong\u003ePower\u003c\/strong\u003e: Wall-mount: 90-240 VAC, 50\/60Hz. Bench-top: 10 to 25 VDC, or 7 to 20 VAC 500mA. (optional, user supplied)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003eOrdering Information:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003e692-0000\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000; font-family: verdana, geneva;\"\u003eBenchtop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000; font-family: verdana, geneva;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e115 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cstrong\u003e69\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cstrong\u003e2-0230\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003eBenchtop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e230 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e692-1000\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003eWall-mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e115 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003e692-1230\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003eWall-mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e230 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2019-10-24T10:48:24-04:00","created_at":"2019-10-24T10:48:24-04:00","vendor":"HCS","type":"","tags":["Controllers\/Sensors","HCS","Process Heat","Tools"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986933633101,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCSTMSC-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS Temperature Monitoring System 12-Channel Scanning","public_title":null,"options":["Default Title"],"price":0,"weight":907,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.37.06_PM.png?v=1572456511"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.37.06_PM.png?v=1572456511","options":["Title"],"media":[{"alt":"HCS Temperature Monitoring System 12-Channel Scanning","id":5533334601805,"position":1,"preview_image":{"aspect_ratio":1.11,"height":309,"width":343,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.37.06_PM.png?v=1572456511"},"aspect_ratio":1.11,"height":309,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/Screen_Shot_2016-11-02_at_1.37.06_PM.png?v=1572456511","width":343}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eStore and recall up to 4680 sets of readings with time and date\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eAutomatically or manually display, record and output temperature readings\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eField calibrate each probe separately - achieve accuracies of ± 0.1% of reading!\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eBidirectional RS-232 for setup or PC data logging\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIncludes a real-time clock, nonvolatile memory, and parallel printer output (benchtop only)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eImmune to RF interference\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eOur Temperature Monitoring System is ideal when simultaneous monitoring of temperatures during different process steps or phases is critical, these new 12-channel scanning thermometers. \u003cbr\u003e\u003cbr\u003eThe wall mount Temperature Monitoring System is ideal for permanent installation and continuous monitoring of your processes. \u003cbr\u003e\u003cbr\u003eThe benchtop Temperature Monitoring System accepts most any power source giving you great flexibility as to where and when it may be used. Both models function as a data logger - store data in the non-volatile memory and later download to your printer or PC. Link both models in series to expand the number of channels you can scan. Each of the 12 thermocouple inputs is programmable to scan from every four seconds to hourly.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003eBENCHTOP THERMOMETER\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eParallel printer connection allows you to connect the thermometer to a printer - make a hard copy of your data as a permanent record\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003ePower unit with included 115 VAC or 230 VAC adapter or any 10 to 25 VDC or 7 to 20 VAC 500 mA power supply. (user supplied)\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eAccepts thermocouple probes with miniconnectors for quick and easy probe changes.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eWALL-MOUNT THERMOMETER\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eUse high and low relays for on\/off control; relays are rated at 250 VAC 2A or 2A at 30 VDC resistive.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eFeatures an easy-to-view drip proof housing with all wire connections on the bottom.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003ePower the unit with 100-240 VAC, 50\/60Hz.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eINSTRUMENT FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eScan and log up to 12 thermocouple inputs from any combination of J, K, T, E, N, B, R, and S thermocouple probes.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eThermocouple type is individually selectable per channel.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eDatalogging feature automatically stores up to 4680 sets of readings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eDownload readings or stored data to your computer.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eLink up to 8 units together to expand channel capacity.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eSequentially captures temperature data, allowing you to monitor and record process variations - ideal for statistical process control.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eEasy-to-use front panel MENU key lets you program data logging and print intervals, scan rate, date and time, temperature scale (°F, °C, K, °R), resolution (0.1 or 1°), channels displayed, thermocouple type, and data output parameters.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eEach channel features HOLD, STORE, MAX and MIN (measures maximum and minimum values), RECALL and AVERAGE buttons.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eCalibrate each channel separately at either one or two points to minimize probe offset. Parameter setup and calibration offsets are stored in nonvolatile memory.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eEach scanner is factory calibrated to NIST-traceable standards.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eMULTIPLE SAFETY FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eMENU key lets you select high or low alarm set points for each channel. Easily enable or disable the audible alarm and set alarm hysteresis; program for manual or automatic alarm reset.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eThermocouple inputs are electrically isolated from each other and from data outputs - provides safe and accurate measurements even when probes are exposed to various electrical conditions.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003ePHYSICAL FEATURES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eLarge 3\/4\" high, 14-segment, 12-character alphanumeric LCD indicates channel number or name, temperature reading, and temperature units.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIndicator light warns you of open probes or out-of-range readings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eBenchtop models accept thermocouple probes with ANSI miniconnectors for quick hookup and changes.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eWall-mount models accept thermocouple probes with stripped ends.\u003c\/span\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: helvetica, arial; font-size: small; color: #000000;\"\u003e\u003cstrong\u003eCOMPUTER\/PRINTER CAPABILITIES for both models\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eUse printing function to send current readings directly to your computer and printer at chosen intervals.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eVary data logging and printing intervals from 4 seconds to 99 minutes, 59 seconds.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eFeatures RS-232 (for both units), and parallel printer output of date and time (benchtop only), channel number and name, and temperature readings in a tabular format.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eIncludes RS-232 cable. Parallel printer cable is not included (sold separately)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; color: #000000;\"\u003eRemember to order the proper probes for your application. Barnant offers a wide variety of thermocouple probes (J, K, T, E, N, R, S, and B) wire, connectors and other accessories to ensure your temperature scanner will provide the ultimate function and performance. \u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003eTemperature Monitoring System Specifications: \u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Verdana;\"\u003eRanges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: Verdana;\"\u003e:\u003cbr\u003e \u003cstrong\u003eJ\u003c\/strong\u003e: -200 to 1000°C (-392 to 1832°F)\u003cbr\u003e \u003cstrong\u003eK\u003c\/strong\u003e: -250 to 1372°C (-418 to 2501°F)\u003cbr\u003e \u003cstrong\u003eT\u003c\/strong\u003e: -250 to 400°C (-418 to 752°F)\u003cbr\u003e \u003cstrong\u003eE\u003c\/strong\u003e: -250 to 1000°C (-418 to 1832°F)\u003cbr\u003e \u003cstrong\u003eN\u003c\/strong\u003e: -250 to 1300°C (-418 to 2372°F)\u003cbr\u003e \u003cstrong\u003eR\u003c\/strong\u003e: 0 to1768°C (32 to 3214°F)\u003cbr\u003e \u003cstrong\u003eS\u003c\/strong\u003e: 0 to 1768°C (32 to 3214°F)\u003cbr\u003e \u003cstrong\u003eB\u003c\/strong\u003e: 200 to 1800°C (392 to 3272°F)\u003cbr\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 0.1°\/1° selectable up to 999.9°, 1° above 1000°; autorange to 1° below -150°C\u003cbr\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: J, K, T, E, N: ±0.1% of rdg., ±0.5°C (±0.8°F) above -150°C; ±0.25% of rdg., ±1°C (±2°F) below -150°C\u003cbr\u003eR, S, B: ±0.1% of reading, ±2°C (±4°F)\u003cbr\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: 12 character alphanumeric LCD\u003cbr\u003e\u003cstrong\u003eDisplay update rate\u003c\/strong\u003e: 3 sec\/channel\u003cbr\u003e\u003cstrong\u003eScan rate\u003c\/strong\u003e: From 4 sec\/12 channels to 99 min 59 sec\/12 channels\u003cbr\u003e\u003cstrong\u003eAlarm output\u003c\/strong\u003e: (Wall-mount units only) SPDT high\/low relays are rated at 250 VAC 2A or 2A at 30 VDC resistive.\u003cbr\u003e\u003cstrong\u003eDigital output\u003c\/strong\u003e: Both models: RS-232, ASCII format, baud rate 19.2 K, RJ11connector;\u003cbr\u003eBenchtop unit only: Centronics parallel printer output; DB25F connector\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Benchtop: 7 1\/2\"L x 10 1\/2\"W x 3 1\/2\"H\u003cbr\u003eWall-mount: 5 1\/2\"L x 11 1\/4\"W x 8 1\/2\"H\u003cbr\u003e\u003cstrong\u003eShpg wt\u003c\/strong\u003e: Benchtop: 3 lb (1.4 kg)\u003cbr\u003eWall-mount: 4 lb (1.8 kg)\u003cbr\u003e\u003cstrong\u003ePower\u003c\/strong\u003e: Wall-mount: 90-240 VAC, 50\/60Hz. Bench-top: 10 to 25 VDC, or 7 to 20 VAC 500mA. (optional, user supplied)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: Verdana;\"\u003eOrdering Information:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003e692-0000\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000; font-family: verdana, geneva;\"\u003eBenchtop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000; font-family: verdana, geneva;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e115 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cstrong\u003e69\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cstrong\u003e2-0230\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003eBenchtop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e230 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e692-1000\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva;\"\u003eWall-mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e115 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003e692-1230\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003eWall-mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, geneva; color: #000000;\"\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e230 VAC 50 \/ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e"}