{"id":6673764515917,"title":"Tempco Mi-Plus ® Band Heaters","handle":"tempco-mi-plus-®-band-heaters","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eSpecially formulated mineral insulated tape providing excellent thermal conductivity and dielectric strength is used to insulate the nickel chrome resistance wire from the stainless steel sheath. The heater assembly is formed under pressure to a precise diameter with a thin low-mass cross section, assuring fast heat-up rates and reduced cycle times.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1400°F (760°C)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNominal Watt Density:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eNozzle Bands — under 3\" diameter: 30-100 W\/in2 (4.7-15.5 W\/cm\u003csup\u003e2\u003c\/sup\u003e)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBarrel Bands — 3\" and greater in diameter: 20-70 W\/in\u003csup\u003e2\u003c\/sup\u003e (3.1-10.9 W\/cm\u003csup\u003e2\u003c\/sup\u003e)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Amperage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"noBullets\"\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e\u003cem\u003eLead Wire Termination:\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003e12.5A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e\u003cem\u003eScrew Terminations:\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e8-32UNF—20A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e10-32UNF—25A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+10%, –5%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+5%, –10%\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cem\u003ePhysical Size Construction Limitations\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNominal Gap—Built-In Bracket:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eless than 1-3\/4\" dia. – 1\/4\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e1-3\/4\" to 2\" dia. – 5\/16\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e2\" to 5\" dia. – 3\/8\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e5\" to 18\" dia. – 1\/2\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003egreater than 18\" dia. – 3\/4\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eIf a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Inside Diameters:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eOne-Piece –*14\" (355.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOne-Piece Expandable – *14\" (355.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eTwo-Piece – 25\" (635.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOver 25\" (635.0 mm) will require multiple segments. Consult TEMPCO.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* Tempco recommends two-piece construction for heaters 10\" ID and greater\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStandard Widths:\u003c\/strong\u003e 1\" to 8\" (25.4 mm to 203.2 mm)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e ±3\/32\" (2.4 mm)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: If non-standard widths or tighter tolerances are required, consult Tempco.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eAdditional Limitations\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eFor heaters less than 4\" in diameter, the maximum width is twice the diameter.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eHeaters with standard brackets are available from 1\" to 8\" wide, while heaters with low profile brackets are available from 1\" to 6\" wide.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e1\" diameter heaters are only available in 1\" and 1-1\/2\" widths.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFor heaters from 10\" diameter up to 25\" diameter, Tempco recommends using 2-piece construction for superior clamping. Over 25\" diameter, 3 or 4 segments are recommended.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eCombinations of some minimum and maximum variations may not be available. Consult Tempco with your special requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePost terminals are only available on heaters greater than 2-1\/2\" in diameter and 1-1\/2\" in width.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiameter\/Width Limitations\u003c\/h4\u003e\n\u003cdiv class=\"scrollTable\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\" colspan=\"2\"\u003eWidth\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eOne-Piece Construction\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eExpandable Construction\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTwo-Piece Construction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1  to  10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4  to  254.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 44.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 50.8  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e114.3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 57.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e127\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e139.7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 69.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e152.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e165.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e190.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e203.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Specifications \u0026amp; Ordering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-2 and 1-3 for Mi-Plus design overviews.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-4 for specific Standard Specifications and Tolerance product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-5 for Maximum Allowable Watt Density information and calculations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOne Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4106%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.5475%;\"\u003e\u003cem\u003eOne-piece heaters provide the most heated surface area but can only be used where the entire heater can be slipped over the end of the barrel. One-piece heaters have built-in, full-width clamping bars.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTwo Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.5396%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.4604%;\"\u003e\u003cem\u003eTwo-piece construction satisfies the need for a heater that can be placed anywhere along the machine barrel and is recommended for larger diameter heaters. The two-piece construction style also provides dual voltage capability as heater halves may be wired together either in series or parallel. Two-piece heaters are rated at full voltage and 1\/2 the total wattage for each half.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOne Piece Expandable Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3327%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.6673%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe expandable construction style allows the heater to be opened up and placed anywhere along the machine barrel, as well as minimizes the unheated area as compared to a two-piece heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWith two heater circuits in a common case this heater naturally lends itself to a dual voltage system. Expandable heaters are rated for each circuit at full voltage and one half of the total wattage.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: It is not recommended to open a One-Piece Expandable Band Heater more than two times.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003ePartial Coverage Band with Built-In Brackets (2 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePartial coverage band heaters are required when an obstruction on the barrel would interfere with a full coverage band.  \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of construction is the 2-piece Band Heater with Built-In Brackets. The heater is bolted down to the cylinder at the ends and the built-in low thermal expansion strap pulls the heater tightly against the cylinder being heated. The standard center of hole to edge of heater dimension is 1\/4\".\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003ePartial Coverage Band with Separate Strap (1 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB102.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB102.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe alternate method of partial coverage construction is the 1-piece Band Heater with a separate 2-piece strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe 2-piece strap itself is bolted at the padded ends, allowing the heater to float between the pads as illustrated below. When tightening the strap, it will pull the heater against the cylinder being heated.  The standard center of hole to edge of heater dimension is 1\/4\".\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eClamping Options:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NB: Standard Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1\/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NS: Standard Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"152\" width=\"152\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NE: Standard Built-In Clamping Strap, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"152\" width=\"152\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1\/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SB: Separate Clamping Straps, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e              \u003cimg height=\"194\" width=\"194\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Size\u003c\/th\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eSuggested Diameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SS: Separate Clamping Straps, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eClearance\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eSuggested\u003cbr data-mce-fragment=\"1\"\u003eDiameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SE: Separate Clamping Straps, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e            \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e                 \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eClearance\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eSuggested Diameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LB: Low-Profile Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg height=\"164\" width=\"164\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LS: Low-Profile Built-In Clamping Strap, Two Piece Band     \u003cspan data-mce-fragment=\"1\"\u003e              \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LE: Low-Profile Built-In Clamping Strap, One Piece Expandable Band \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType OB: Outrigger Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis design is unique to 1\" wide heaters from 1-3\/8\" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1\" wide heaters the required clamping power.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on Mi-Plus heaters 1\" wide and 1-3\/8\" in diameter and greater.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType OS: Outrigger Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis design is unique to 1\" wide heaters from 1-3\/8\" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1\" wide heaters the required clamping power.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on Mi-Plus heaters 1\" wide and 1-3\/8\" in diameter and greater.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SL: Spring Loaded Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e\u003cspan\u003e 3-1\/2\" (88.9 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSL: Spring Loaded Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NEL: Spring Loaded Built-In Clamping Strap, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WB: Weld-On Bracket, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps.  Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Size\u003c\/th\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WS: Weld-On Bracket, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WE: Weld-On Bracket, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg?Small\"\u003e              \u003cimg height=\"178\" width=\"178\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3Y: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg?Small\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 8-32 Post Terminals — 2\" (50.8 mm), With 10-32 Post Terminals — 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-15 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 20px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 20px;\" data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg?Small\"\u003e             \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.4375px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 17.4375px;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg?Small\"\u003e       \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; near edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg?Small\"\u003e       \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; near edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.8542%;\" data-mce-fragment=\"1\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB579.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB579.jpg\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.8604%;\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg?Small\"\u003e        \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis low-profile termination is convenient where space limitations are a concern. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 10\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis low-profile termination is convenient where space limitations are a concern. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 10 each half\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for additional construction and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 217px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 217px;\" data-mce-fragment=\"1\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg?Small\"\u003e            \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.2188px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 19.2188px;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Right Angle Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"scrollTable\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2B: Abrasion-Resistant Right Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 217px;\"\u003e\n\u003ctd style=\"height: 217px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg?Small\"\u003e          \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.2188px;\"\u003e\n\u003ctd style=\"height: 18.2188px;\"\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2B: Abrasion-Resistant Right Angle Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg\" width=\"173\" height=\"173\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg?Small\"\u003e      \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for Lead Wire, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg height=\"163\" width=\"163\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg?Small\"\u003e               \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/12.5A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 167px;\"\u003e\n\u003ctd style=\"height: 167px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg?Small\"\u003e                    \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" width=\"123\" height=\"123\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.2188px;\"\u003e\n\u003ctd style=\"height: 17.2188px;\"\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e        \u003cimg height=\"213\" width=\"213\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg?Small\"\u003e            \u003cimg height=\"123\" width=\"123\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e two sets of leads opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg?Small\"\u003e            \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/25A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003cbr\u003e\u003cstrong\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003cbr\u003e\u003cstrong\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003cbr\u003e\u003cstrong\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 187px;\"\u003e\n\u003ctd style=\"height: 187px;\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg?Small\"\u003e           \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint18.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint18.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 245.219px;\"\u003e\n\u003ctd style=\"height: 245.219px;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/25A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003cbr\u003e\u003cstrong\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003cbr\u003e\u003cstrong\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003cbr\u003e\u003cstrong\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg?Small\"\u003e            \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e\u003cspan\u003e1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/12.5A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg?Small\"\u003e           \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" width=\"203\" height=\"203\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e center of each half; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg?Small\"\u003e          \u003cimg height=\"203\" width=\"203\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e two sets of leads opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 659px;\"\u003e\n\u003ctd style=\"width: 32.1295%; text-align: center; height: 659px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e          Type P1H                           \u003c\/strong\u003e\u003cstrong\u003e                 \u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB261BC.jpg?Medium\" alt=\"Type P1H Shown\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB261BC.jpg?Medium\"\u003e        \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCup \u003c\/strong\u003e\u003cstrong\u003eAssembly Only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"Cup Assembly Only\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint19.jpg?Medium\" width=\"123\" height=\"123\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eCup Assembly w\/90\u003cspan data-mce-fragment=\"1\"\u003e° Plug\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Cup Assembly with 90° Plug\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint22.jpg?Medium\" width=\"153\" height=\"153\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.3653%; height: 659px;\"\u003e\n\u003cp\u003e\u003cem\u003eQuick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250VAC           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1A\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly only\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1B\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1C\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1E\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1F\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel wire braid\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1H\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1J\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-20 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.576%;\" data-mce-selected=\"1\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType P1H\u003c\/strong\u003e\u003cbr\u003e        \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e  Cup Assembly Only\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg height=\"123\" width=\"123\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint19.jpg?Medium\" alt=\"Cup Assembly Only\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCup Assembly w\/90\u003cspan data-mce-fragment=\"1\"\u003e° Plug\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint22.jpg?Medium\" alt=\"Cup Assembly with 90° Plug\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.424%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eQuick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250VAC           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1A\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly only\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1B\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1C\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1E\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1F\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel wire braid\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1H\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1J\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-20 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9562%;\"\u003e\n\u003cp\u003e     \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e   \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"123\" width=\"123\" alt=\"Type P2A Shown\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB153.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB153.jpg?Medium\"\u003e\u003cbr\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"180\" width=\"180\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.0438%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9562%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"123\" width=\"123\" alt=\"Type P2A Shown\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB267BC.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB267BC.jpg?Medium\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\" width=\"180\" height=\"180\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.0438%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB269BC.jpg?Medium\" alt=\"Type P2A Shown\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB269BC.jpg?Medium\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint24.jpg?Medium\" width=\"183\" height=\"183\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint24.jpg?Medium\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Options\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eThermocouple Coupling\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg?Small\"\u003e          \u003cimg height=\"203\" width=\"203\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eThe Thermocouple Coupling facilitates the installation of an external thermocouple with a threaded fitting. The standard location for the coupling is 90° from the gap at the center of the width. Specify without through hole for heater sensing or with through hole for load sensing.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eThread\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eD\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/8-27 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e9\/16\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e11\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/8-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\/8\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eM12-1.75mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eThermocouple Bayonet Adapter\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg?Small\"\u003e             \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA standard Bayonet Adapter facilitates the installation of an external thermocouple with a standard bayonet cap. The standard location for the adapter is 90° from the gap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSee \u003ca\u003eTemperature Sensors\u003c\/a\u003e for a complete selection of thermocouples available from stock.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eBuilt-In Thermocouple\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg height=\"101\" width=\"202\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA built-in thermocouple can be factory installed on Mi-Plus band heaters. ANSI type J or K thermocouples are available on Type L1, R,1 R2, W1, W2 and W5 lead wire terminations. Thermocouple junction is located inside the exit termination stamping, providing a relative heater temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThermocouple can be located in various positions on the heater. Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStock Heavy-Duty Quick Disconnect Plugs and Adapters\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cimg height=\"93\" width=\"93\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT123.jpg?Medium\" alt=\"P1\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P2\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT124.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT124.jpg?Medium\"\u003e\u003cimg height=\"91\" width=\"91\" alt=\"P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT125.jpg?Medium\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P5\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHeaters with pre-wired plugs allow quick and easy installation of the heater. These plugs can be attached to armor cable or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor other types of plugs, consult Tempco or specify the manufacturer's part number when ordering. See \u003ca\u003eAccessories\u003c\/a\u003e for additional Twist-Lock electrical plugs.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 485px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 73px;\"\u003eReference\u003c\/th\u003e\n\u003cth style=\"width: 87.3125px; text-align: center;\"\u003e     NEMA      Plug or Receptacle\u003c\/th\u003e\n\u003cth style=\"width: 43.6875px;\"\u003eAmps\u003c\/th\u003e\n\u003cth style=\"width: 55px;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"width: 75px;\"\u003e\n\u003cp\u003ePlug Part  Number\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 100px;\"\u003eConnectors (Female) Part Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP1 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL1-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-102\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\" rowspan=\"2\"\u003eP2 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\" rowspan=\"2\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\" rowspan=\"2\"\u003eEHD-102-107\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\" rowspan=\"2\"\u003eEHD-103-103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP3 straight\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003e5-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-103\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP4 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL5-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-113\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP5 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL6-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-121\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP6 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL6-20\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-122\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIgloo Ceramic Terminal Covers for Screw Terminals\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable style=\"width: 96.7696%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 23.9264%;\"\u003e\n\u003cp\u003e Double Port In-Line\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB144BC.jpg?Medium\" alt=\"Double Port In-Line\"\u003e\u003c\/p\u003e\n\u003cp\u003e                     Single Port\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB146BC.jpg?Medium\" alt=\"Single Port\"\u003e\u003c\/p\u003e\n\u003cp\u003e                              Double Port 90\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB145BC.jpg?Medium\" alt=\"Double Port 90°\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 69.3667%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIgloo™ ceramic terminal covers consist of two individual ceramic parts. With a tight-fitting cap and a solid base, an Igloo will fully insulate any standard #8 or #10 terminal lug used for electrical wiring hookups. Igloos can be assembled onto any standard Mi-Plus Band with 8-32 or 10-32 screw terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eThree types of Igloo™ bases are available:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e — Double Port In-Line P\/N CER-101-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e — Double Port 90° P\/N CER-101-106\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e — Single Port P\/N CER-101-107\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eIgloo™ caps are available in the three screw terminal sizes:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-32\u003c\/strong\u003e — P\/N CER-102-101\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-24\u003c\/strong\u003e — P\/N CER-102-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e8-32\u003c\/strong\u003e — P\/N CER-102-105\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWhen ordering, specify the type of Igloo and the screw terminal size.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eIgloo Double Port 90° are recommended on expandable heaters with Type T3X Termination.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eIgloo Double Port In-Line will not fit on expandable heaters with Type T3X termination.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eSee reference page 1-15 for additional specifications and ordering information.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"Float75 Freeform noHeight New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float75 Freeform noHeight New50 CenterZone TitanBlock\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003e\u003c\/h5\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem\u003eCommon Applications\u003c\/em\u003e\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2021-10-04T08:36:51-04:00","created_at":"2021-10-04T08:36:28-04:00","vendor":"Tempco","type":"Replacement Parts","tags":["Electronics","Food \u0026 Beverage","Heaters","Manufacturing","Medical \u0026 Pharmaceutical Production","Plastic Fabrication","Process Heat","Replacement Parts","Tempco"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39491363930189,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MPP50101","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Tempco Mi-Plus ® Band Heaters","public_title":null,"options":["Default Title"],"price":0,"weight":2268,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters.png?v=1633354331","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-1.png?v=1633366849","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-2.png?v=1633366897","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-3.png?v=1633366898","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-4.png?v=1633366900","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-5.png?v=1633366899","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-6.png?v=1633366896","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-7.png?v=1633366897","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-8.png?v=1633366896","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-9.png?v=1633366901","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-10.png?v=1633366899","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-11.png?v=1633366896","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-12.png?v=1633366900","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-13.png?v=1633366899","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-14.png?v=1633366896","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-15.png?v=1633366897","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-16.png?v=1633366899","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-17.png?v=1633366898","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-18.png?v=1633366898","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-19.png?v=1633366897","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-20.png?v=1633366898","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-21.png?v=1633366901"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters.png?v=1633354331","options":["Title"],"media":[{"alt":null,"id":21033163784269,"position":1,"preview_image":{"aspect_ratio":1.089,"height":484,"width":527,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters.png?v=1633354331"},"aspect_ratio":1.089,"height":484,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters.png?v=1633354331","width":527},{"alt":null,"id":21033681387597,"position":2,"preview_image":{"aspect_ratio":0.776,"height":861,"width":668,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-1.png?v=1633366849"},"aspect_ratio":0.776,"height":861,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-1.png?v=1633366849","width":668},{"alt":null,"id":21033684140109,"position":3,"preview_image":{"aspect_ratio":0.836,"height":833,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-2.png?v=1633366897"},"aspect_ratio":0.836,"height":833,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-2.png?v=1633366897","width":696},{"alt":null,"id":21033684172877,"position":4,"preview_image":{"aspect_ratio":0.834,"height":831,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-3.png?v=1633366898"},"aspect_ratio":0.834,"height":831,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-3.png?v=1633366898","width":693},{"alt":null,"id":21033684205645,"position":5,"preview_image":{"aspect_ratio":0.832,"height":835,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-4.png?v=1633366900"},"aspect_ratio":0.832,"height":835,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-4.png?v=1633366900","width":695},{"alt":null,"id":21033684238413,"position":6,"preview_image":{"aspect_ratio":0.83,"height":827,"width":686,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-5.png?v=1633366899"},"aspect_ratio":0.83,"height":827,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-5.png?v=1633366899","width":686},{"alt":null,"id":21033684271181,"position":7,"preview_image":{"aspect_ratio":0.839,"height":828,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-6.png?v=1633366896"},"aspect_ratio":0.839,"height":828,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-6.png?v=1633366896","width":695},{"alt":null,"id":21033684303949,"position":8,"preview_image":{"aspect_ratio":0.837,"height":829,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-7.png?v=1633366897"},"aspect_ratio":0.837,"height":829,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-7.png?v=1633366897","width":694},{"alt":null,"id":21033684336717,"position":9,"preview_image":{"aspect_ratio":0.838,"height":828,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-8.png?v=1633366896"},"aspect_ratio":0.838,"height":828,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-8.png?v=1633366896","width":694},{"alt":null,"id":21033684369485,"position":10,"preview_image":{"aspect_ratio":0.834,"height":832,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-9.png?v=1633366901"},"aspect_ratio":0.834,"height":832,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-9.png?v=1633366901","width":694},{"alt":null,"id":21033684402253,"position":11,"preview_image":{"aspect_ratio":0.842,"height":827,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-10.png?v=1633366899"},"aspect_ratio":0.842,"height":827,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-10.png?v=1633366899","width":696},{"alt":null,"id":21033684435021,"position":12,"preview_image":{"aspect_ratio":0.84,"height":830,"width":697,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-11.png?v=1633366896"},"aspect_ratio":0.84,"height":830,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-11.png?v=1633366896","width":697},{"alt":null,"id":21033684467789,"position":13,"preview_image":{"aspect_ratio":0.833,"height":833,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-12.png?v=1633366900"},"aspect_ratio":0.833,"height":833,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-12.png?v=1633366900","width":694},{"alt":null,"id":21033684500557,"position":14,"preview_image":{"aspect_ratio":0.83,"height":834,"width":692,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-13.png?v=1633366899"},"aspect_ratio":0.83,"height":834,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-13.png?v=1633366899","width":692},{"alt":null,"id":21033684533325,"position":15,"preview_image":{"aspect_ratio":1.338,"height":861,"width":1152,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-14.png?v=1633366896"},"aspect_ratio":1.338,"height":861,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-14.png?v=1633366896","width":1152},{"alt":null,"id":21033684566093,"position":16,"preview_image":{"aspect_ratio":0.813,"height":854,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-15.png?v=1633366897"},"aspect_ratio":0.813,"height":854,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-15.png?v=1633366897","width":694},{"alt":null,"id":21033684598861,"position":17,"preview_image":{"aspect_ratio":0.806,"height":862,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-16.png?v=1633366899"},"aspect_ratio":0.806,"height":862,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-16.png?v=1633366899","width":695},{"alt":null,"id":21033684631629,"position":18,"preview_image":{"aspect_ratio":0.832,"height":833,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-17.png?v=1633366898"},"aspect_ratio":0.832,"height":833,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-17.png?v=1633366898","width":693},{"alt":null,"id":21033684664397,"position":19,"preview_image":{"aspect_ratio":0.839,"height":830,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-18.png?v=1633366898"},"aspect_ratio":0.839,"height":830,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-18.png?v=1633366898","width":696},{"alt":null,"id":21033684697165,"position":20,"preview_image":{"aspect_ratio":0.794,"height":870,"width":691,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-19.png?v=1633366897"},"aspect_ratio":0.794,"height":870,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-19.png?v=1633366897","width":691},{"alt":null,"id":21033684729933,"position":21,"preview_image":{"aspect_ratio":0.838,"height":829,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-20.png?v=1633366898"},"aspect_ratio":0.838,"height":829,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-20.png?v=1633366898","width":695},{"alt":null,"id":21033684762701,"position":22,"preview_image":{"aspect_ratio":0.836,"height":831,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-21.png?v=1633366901"},"aspect_ratio":0.836,"height":831,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoMi-PlusBandHeaters-21.png?v=1633366901","width":695}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eSpecially formulated mineral insulated tape providing excellent thermal conductivity and dielectric strength is used to insulate the nickel chrome resistance wire from the stainless steel sheath. The heater assembly is formed under pressure to a precise diameter with a thin low-mass cross section, assuring fast heat-up rates and reduced cycle times.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1400°F (760°C)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNominal Watt Density:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eNozzle Bands — under 3\" diameter: 30-100 W\/in2 (4.7-15.5 W\/cm\u003csup\u003e2\u003c\/sup\u003e)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eBarrel Bands — 3\" and greater in diameter: 20-70 W\/in\u003csup\u003e2\u003c\/sup\u003e (3.1-10.9 W\/cm\u003csup\u003e2\u003c\/sup\u003e)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cem\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Amperage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"noBullets\"\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e\u003cem\u003eLead Wire Termination:\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003e12.5A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e\u003cem\u003eScrew Terminations:\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e8-32UNF—20A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"noBullets\"\u003e10-32UNF—25A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+10%, –5%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWattage Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+5%, –10%\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eCaution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cem\u003ePhysical Size Construction Limitations\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNominal Gap—Built-In Bracket:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eless than 1-3\/4\" dia. – 1\/4\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e1-3\/4\" to 2\" dia. – 5\/16\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e2\" to 5\" dia. – 3\/8\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e5\" to 18\" dia. – 1\/2\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003egreater than 18\" dia. – 3\/4\"\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eIf a larger gap is required for probes or thermocouples, specify when ordering.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Inside Diameters:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eOne-Piece –*14\" (355.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOne-Piece Expandable – *14\" (355.6 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eTwo-Piece – 25\" (635.0 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOver 25\" (635.0 mm) will require multiple segments. Consult TEMPCO.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* Tempco recommends two-piece construction for heaters 10\" ID and greater\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStandard Widths:\u003c\/strong\u003e 1\" to 8\" (25.4 mm to 203.2 mm)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWidth Tolerance:\u003c\/strong\u003e ±3\/32\" (2.4 mm)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: If non-standard widths or tighter tolerances are required, consult Tempco.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eAdditional Limitations\u003c\/em\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eFor heaters less than 4\" in diameter, the maximum width is twice the diameter.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eHeaters with standard brackets are available from 1\" to 8\" wide, while heaters with low profile brackets are available from 1\" to 6\" wide.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e1\" diameter heaters are only available in 1\" and 1-1\/2\" widths.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eFor heaters from 10\" diameter up to 25\" diameter, Tempco recommends using 2-piece construction for superior clamping. Over 25\" diameter, 3 or 4 segments are recommended.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eCombinations of some minimum and maximum variations may not be available. Consult Tempco with your special requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003ePost terminals are only available on heaters greater than 2-1\/2\" in diameter and 1-1\/2\" in width.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiameter\/Width Limitations\u003c\/h4\u003e\n\u003cdiv class=\"scrollTable\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\" colspan=\"2\"\u003eWidth\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eOne-Piece Construction\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eExpandable Construction\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTwo-Piece Construction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eInside Diameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003emm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1  to  10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4  to  254.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 25.4  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 50.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 38.1  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 44.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 50.8  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e4-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e114.3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 57.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e127\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e5-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e139.7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 69.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 63.5  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e152.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 76.2  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e6-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e165.1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 82.6  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e177.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-1⁄2  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 88.9  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e7-1⁄2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e190.5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3-3⁄4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 95.3  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e203.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  14\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  355.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4  to  25\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e101.6  to  635.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Specifications \u0026amp; Ordering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-2 and 1-3 for Mi-Plus design overviews.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-4 for specific Standard Specifications and Tolerance product information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-5 for Maximum Allowable Watt Density information and calculations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDesign Features:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOne Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4106%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB108BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.5475%;\"\u003e\u003cem\u003eOne-piece heaters provide the most heated surface area but can only be used where the entire heater can be slipped over the end of the barrel. One-piece heaters have built-in, full-width clamping bars.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTwo Piece Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.5396%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB110BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.4604%;\"\u003e\u003cem\u003eTwo-piece construction satisfies the need for a heater that can be placed anywhere along the machine barrel and is recommended for larger diameter heaters. The two-piece construction style also provides dual voltage capability as heater halves may be wired together either in series or parallel. Two-piece heaters are rated at full voltage and 1\/2 the total wattage for each half.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eOne Piece Expandable Band Construction\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3327%;\"\u003e \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB112BC.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.6673%;\"\u003e\n\u003cp\u003e\u003cem\u003eThe expandable construction style allows the heater to be opened up and placed anywhere along the machine barrel, as well as minimizes the unheated area as compared to a two-piece heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWith two heater circuits in a common case this heater naturally lends itself to a dual voltage system. Expandable heaters are rated for each circuit at full voltage and one half of the total wattage.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eCaution: It is not recommended to open a One-Piece Expandable Band Heater more than two times.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003ePartial Coverage Band with Built-In Brackets (2 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB250BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB103.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePartial coverage band heaters are required when an obstruction on the barrel would interfere with a full coverage band.  \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe preferred method of construction is the 2-piece Band Heater with Built-In Brackets. The heater is bolted down to the cylinder at the ends and the built-in low thermal expansion strap pulls the heater tightly against the cylinder being heated. The standard center of hole to edge of heater dimension is 1\/4\".\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003ePartial Coverage Band with Separate Strap (1 Piece)\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e                \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB251BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB102.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB102.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe alternate method of partial coverage construction is the 1-piece Band Heater with a separate 2-piece strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe 2-piece strap itself is bolted at the padded ends, allowing the heater to float between the pads as illustrated below. When tightening the strap, it will pull the heater against the cylinder being heated.  The standard center of hole to edge of heater dimension is 1\/4\".\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eClamping Options:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NB: Standard Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1\/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NS: Standard Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"152\" width=\"152\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NE: Standard Built-In Clamping Strap, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"152\" width=\"152\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB148BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint3.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1\/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter: \u003c\/strong\u003e3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters 3\" in diameter \u0026amp; larger.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for Installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SB: Separate Clamping Straps, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e              \u003cimg height=\"194\" width=\"194\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Size\u003c\/th\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eSuggested Diameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SS: Separate Clamping Straps, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e              \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eClearance\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eSuggested\u003cbr data-mce-fragment=\"1\"\u003eDiameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SE: Separate Clamping Straps, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e            \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB253BC.jpg?Small\"\u003e                 \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-12 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eClearance\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003eSuggested Diameter Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\" – 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e2\" – 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u0026gt; 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LB: Low-Profile Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg height=\"164\" width=\"164\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LS: Low-Profile Built-In Clamping Strap, Two Piece Band     \u003cspan data-mce-fragment=\"1\"\u003e              \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType LE: Low-Profile Built-In Clamping Strap, One Piece Expandable Band \u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB149BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint4.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eWhen space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3\" in diameter.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1-3\/8\" (34.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on all Mi-Plus heaters less than 3\" in diameter\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType OB: Outrigger Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis design is unique to 1\" wide heaters from 1-3\/8\" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1\" wide heaters the required clamping power.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on Mi-Plus heaters 1\" wide and 1-3\/8\" in diameter and greater.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType OS: Outrigger Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB150BC.jpg?Small\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint5.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis design is unique to 1\" wide heaters from 1-3\/8\" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1\" wide heaters the required clamping power.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Standard on Mi-Plus heaters 1\" wide and 1-3\/8\" in diameter and greater.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType SL: Spring Loaded Built-In Clamping Strap, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e\u003cspan\u003e 3-1\/2\" (88.9 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NSL: Spring Loaded Built-In Clamping Strap, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType NEL: Spring Loaded Built-In Clamping Strap, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB152.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint6A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSpring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8\" in diameter and offered as an option on any heater with standard brackets. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 3-1\/2\" (88.9 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WB: Weld-On Bracket, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps.  Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Size\u003c\/th\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WS: Weld-On Bracket, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg height=\"163\" width=\"163\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType WE: Weld-On Bracket, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC502.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB10A.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eThe Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLimitations\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-13 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eBolt Size\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eClearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e8-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e10-32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e1\/4-20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Terminations\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB114BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (8-32)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB115BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T2: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB117BC.jpg?Small\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003ePost Terminals:\u003c\/strong\u003e 10-32 or 8-32\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12\" Leads, 10\" Stainless Steel Braid Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB118BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB119BC.jpg?Small\"\u003e              \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3X: Screw Terminals, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB121BC.jpg?Small\"\u003e              \u003cimg height=\"178\" width=\"178\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 10-32 Post Terminals — 2-1\/2\" (63.5 mm), With 8-32 Post Terminals — 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/ 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOrdering Information:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-14 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType T3Y: Screw Terminals, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB122BC.jpg?Small\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint7.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e next to same gap on each half; across center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003eWith 8-32 Post Terminals — 2\" (50.8 mm), With 10-32 Post Terminals — 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 25A (10-32) or 20A (8-32) each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-15 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB133BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB134BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" width=\"193\" height=\"193\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 20px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 20px;\" data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB135BC.jpg?Small\"\u003e             \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint12.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.4375px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 17.4375px;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThe lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10\" of stainless steel loose wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference pages 1-15 and 1-16 for construction - installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB123BC.jpg?Small\"\u003e       \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThis style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; near edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB125BC.jpg?Small\"\u003e       \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint89.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; near edge of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.8542%;\" data-mce-fragment=\"1\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB579.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB579.jpg\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.8604%;\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-16 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB124BC.jpg?Small\"\u003e        \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis low-profile termination is convenient where space limitations are a concern. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 10\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB126BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint10.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis low-profile termination is convenient where space limitations are a concern. The standard leads are 10\" of stainless steel wire braid over 12\" of flexible leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC each half\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 10 each half\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB130BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 480VAC\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e 12.5\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e               \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB131BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for additional construction and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Straight Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr style=\"height: 217px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 217px;\" data-mce-fragment=\"1\"\u003e               \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB132BC.jpg?Small\"\u003e            \u003cimg height=\"213\" width=\"213\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint14.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.2188px;\" data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"height: 19.2188px;\" data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eStainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R1: Abrasion-Resistant Right Angle Armor Cable, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg\" width=\"163\" height=\"163\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB254BC.jpg?Small\"\u003e         \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width: \u003c\/strong\u003e1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-17 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"scrollTable\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2B: Abrasion-Resistant Right Angle Armor Cable, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 217px;\"\u003e\n\u003ctd style=\"height: 217px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB255BC.jpg?Small\"\u003e          \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.2188px;\"\u003e\n\u003ctd style=\"height: 18.2188px;\"\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2B: Abrasion-Resistant Right Angle Armor Cable, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg\" width=\"173\" height=\"173\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB256BC.jpg?Small\"\u003e      \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\" width=\"213\" height=\"213\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint20.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eStainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10\" of stainless steel armor cable over 12\" of lead wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandard Termination Location:\u003c\/strong\u003e two sets of leads opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Width:\u003c\/strong\u003e 1-1\/2\" (38.1 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for Lead Wire, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e             \u003cimg height=\"163\" width=\"163\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebBC501.jpg?Small\"\u003e               \u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/12.5A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 167px;\"\u003e\n\u003ctd style=\"height: 167px;\"\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_2pcDrwng.jpg?Small\"\u003e                    \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" width=\"123\" height=\"123\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.2188px;\"\u003e\n\u003ctd style=\"height: 17.2188px;\"\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 1\" (25.4 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e480VAC\/12.5A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e        \u003cimg height=\"213\" width=\"213\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1PcExpndDrwng.jpg?Small\"\u003e            \u003cimg height=\"123\" width=\"123\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebR2H_1pcDrwng.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHigh Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e two sets of leads opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-18 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB136BC.jpg?Small\"\u003e            \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/25A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003cbr\u003e\u003cstrong\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003cbr\u003e\u003cstrong\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003cbr\u003e\u003cstrong\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB137BC.jpg?Small\"\u003e            \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\" width=\"183\" height=\"183\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint21.jpg?Medium\"\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e center of each half; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e 480VAC\/25A each half\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType C: General Purpose Terminal Box, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 187px;\"\u003e\n\u003ctd style=\"height: 187px;\"\u003e              \u003cimg height=\"163\" width=\"163\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB138BC.jpg?Small\"\u003e           \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint18.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint18.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 245.219px;\"\u003e\n\u003ctd style=\"height: 245.219px;\"\u003e\n\u003cp\u003e\u003cem\u003eThe Heavy Duty Stainless Steel Terminal Box has a 1\/2\" trade size knockout (actual diameter 7\/8\") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/25A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eType CA \u003c\/strong\u003e– Box only (shown)\u003cbr\u003e\u003cstrong\u003eType CD \u003c\/strong\u003e– Box with prewired SS wire braid\u003cbr\u003e\u003cstrong\u003eType CC \u003c\/strong\u003e– Box with prewired SS armor cable\u003cbr\u003e\u003cstrong\u003eType CE \u003c\/strong\u003e– Box with prewired plain leads\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB127BC.jpg?Small\"\u003e            \u003cimg height=\"193\" width=\"193\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter: \u003c\/strong\u003e\u003cspan\u003e1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003c\/strong\u003e\u003cspan\u003e 480VAC\/12.5A\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg\" width=\"153\" height=\"153\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB128BC.jpg?Small\"\u003e           \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" width=\"203\" height=\"203\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e center of each half; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1\" (25.4 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType L1: Plain Wire Leads, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB129BC.jpg?Small\"\u003e          \u003cimg height=\"203\" width=\"203\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint16.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003ePlain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10\" long.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e two sets of leads opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 2-1\/2\" (63.5 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\" (38.1 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts\/Amps: \u003c\/strong\u003e\u003cspan\u003e480VAC\/12.5A each half\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eNote: Plain wire leads do not offer protection against contamination or abrasion.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-19 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 659px;\"\u003e\n\u003ctd style=\"width: 32.1295%; text-align: center; height: 659px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e          Type P1H                           \u003c\/strong\u003e\u003cstrong\u003e                 \u003c\/strong\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB261BC.jpg?Medium\" alt=\"Type P1H Shown\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB261BC.jpg?Medium\"\u003e        \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCup \u003c\/strong\u003e\u003cstrong\u003eAssembly Only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"Cup Assembly Only\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint19.jpg?Medium\" width=\"123\" height=\"123\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eCup Assembly w\/90\u003cspan data-mce-fragment=\"1\"\u003e° Plug\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Cup Assembly with 90° Plug\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint22.jpg?Medium\" width=\"153\" height=\"153\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.3653%; height: 659px;\"\u003e\n\u003cp\u003e\u003cem\u003eQuick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250VAC           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1A\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly only\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1B\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1C\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1E\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1F\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel wire braid\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1H\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1J\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-20 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P1: Quick Disconnect Plugs, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.576%;\" data-mce-selected=\"1\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eType P1H\u003c\/strong\u003e\u003cbr\u003e        \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB263BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e  Cup Assembly Only\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg height=\"123\" width=\"123\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint19.jpg?Medium\" alt=\"Cup Assembly Only\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCup Assembly w\/90\u003cspan data-mce-fragment=\"1\"\u003e° Plug\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"153\" width=\"153\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint22.jpg?Medium\" alt=\"Cup Assembly with 90° Plug\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.424%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eQuick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e opposite the gap; center of width\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 3\" (76.2 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e 2\" (50.8 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e 250VAC           \u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps: \u003c\/strong\u003e16\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 392°F (200°C)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1A\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly only\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1B\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1C\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1E\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1F\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with straight plug and stainless steel wire braid\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1H\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel armor cable\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eP1J\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e— Cup Assembly with 90° plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-20 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9562%;\"\u003e\n\u003cp\u003e     \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB266BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e   \u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"123\" width=\"123\" alt=\"Type P2A Shown\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB153.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB153.jpg?Medium\"\u003e\u003cbr\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"180\" width=\"180\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.0438%;\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, Two Piece Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9562%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB268BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"123\" width=\"123\" alt=\"Type P2A Shown\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB267BC.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB267BC.jpg?Medium\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\" width=\"180\" height=\"180\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint23.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.0438%;\" data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eType P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Expandable Band\u003c\/h4\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg\" width=\"153\" height=\"153\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB270BC.jpg?Small\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB269BC.jpg?Medium\" alt=\"Type P2A Shown\" width=\"123\" height=\"123\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB269BC.jpg?Medium\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint24.jpg?Medium\" width=\"183\" height=\"183\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPrint24.jpg?Medium\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-selected=\"1\"\u003e\n\u003cp\u003e\u003cem\u003eThis lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTo simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10\" of protection over 12\" of flexible leads.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eStandard Termination Location:\u003c\/strong\u003e\u003cspan\u003e opposite the gap; center of width\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e\u003cspan\u003e 3\" (76.2 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width:\u003c\/strong\u003e\u003cspan\u003e 2\" (50.8 mm)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Volts:\u003c\/strong\u003e\u003cspan\u003e 250VAC    \u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Amps:\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e\u003cspan\u003e 572°F (300°C)\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eP2A\u003c\/strong\u003e — Box and Cup only\u003cbr\u003e\u003cstrong\u003eP2B\u003c\/strong\u003e — Box and Cup with straight plug\u003cbr\u003e\u003cstrong\u003eP2D\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel armor cable\u003cbr\u003e\u003cstrong\u003eP2E\u003c\/strong\u003e — Box and Cup with straight plug and stainless steel wire braid\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-21 for construction and installation information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 1-23 for additional installation recommendations.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAdditional Options\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eThermocouple Coupling\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e           \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB258BC.jpg?Small\"\u003e          \u003cimg height=\"203\" width=\"203\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB114.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eThe Thermocouple Coupling facilitates the installation of an external thermocouple with a threaded fitting. The standard location for the coupling is 90° from the gap at the center of the width. Specify without through hole for heater sensing or with through hole for load sensing.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eThread\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eD\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/8-27 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e9\/16\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/4-20 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e11\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/8-18 NPT\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7\/8\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eM12-1.75mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eThermocouple Bayonet Adapter\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e              \u003cimg height=\"153\" width=\"153\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB259BC.jpg?Small\"\u003e             \u003cimg height=\"183\" width=\"183\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebMB115.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA standard Bayonet Adapter facilitates the installation of an external thermocouple with a standard bayonet cap. The standard location for the adapter is 90° from the gap.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSee \u003ca\u003eTemperature Sensors\u003c\/a\u003e for a complete selection of thermocouples available from stock.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eBuilt-In Thermocouple\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cimg height=\"101\" width=\"202\" alt=\"\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg?Small\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebPAGE1-23.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA built-in thermocouple can be factory installed on Mi-Plus band heaters. ANSI type J or K thermocouples are available on Type L1, R,1 R2, W1, W2 and W5 lead wire terminations. Thermocouple junction is located inside the exit termination stamping, providing a relative heater temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThermocouple can be located in various positions on the heater. Consult Tempco with your requirements.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStock Heavy-Duty Quick Disconnect Plugs and Adapters\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cimg height=\"93\" width=\"93\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT123.jpg?Medium\" alt=\"P1\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P2\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT124.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT124.jpg?Medium\"\u003e\u003cimg height=\"91\" width=\"91\" alt=\"P3\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT125.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT125.jpg?Medium\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P4\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT126.jpg?Medium\"\u003e\u003cimg height=\"93\" width=\"93\" alt=\"P5\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/15-Accessories-Images\/WebT127.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eHeaters with pre-wired plugs allow quick and easy installation of the heater. These plugs can be attached to armor cable or stainless steel wire braid.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor other types of plugs, consult Tempco or specify the manufacturer's part number when ordering. See \u003ca\u003eAccessories\u003c\/a\u003e for additional Twist-Lock electrical plugs.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 485px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 73px;\"\u003eReference\u003c\/th\u003e\n\u003cth style=\"width: 87.3125px; text-align: center;\"\u003e     NEMA      Plug or Receptacle\u003c\/th\u003e\n\u003cth style=\"width: 43.6875px;\"\u003eAmps\u003c\/th\u003e\n\u003cth style=\"width: 55px;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"width: 75px;\"\u003e\n\u003cp\u003ePlug Part  Number\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 100px;\"\u003eConnectors (Female) Part Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP1 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL1-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-102\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\" rowspan=\"2\"\u003eP2 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\" rowspan=\"2\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\" rowspan=\"2\"\u003eEHD-102-107\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\" rowspan=\"2\"\u003eEHD-103-103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP3 straight\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003e5-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-103\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP4 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL5-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e125V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-113\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP5 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL6-15\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-121\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 73px; text-align: center;\"\u003eP6 twist lock\u003c\/td\u003e\n\u003ctd style=\"width: 87.3125px; text-align: center;\"\u003eL6-20\u003c\/td\u003e\n\u003ctd style=\"width: 43.6875px; text-align: center;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"width: 55px; text-align: center;\"\u003e250V\u003c\/td\u003e\n\u003ctd style=\"width: 75px; text-align: center;\"\u003eEHD-102-122\u003c\/td\u003e\n\u003ctd style=\"width: 100px; text-align: center;\"\u003eEHD-103-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIgloo Ceramic Terminal Covers for Screw Terminals\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable style=\"width: 96.7696%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 23.9264%;\"\u003e\n\u003cp\u003e Double Port In-Line\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB144BC.jpg?Medium\" alt=\"Double Port In-Line\"\u003e\u003c\/p\u003e\n\u003cp\u003e                     Single Port\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB146BC.jpg?Medium\" alt=\"Single Port\"\u003e\u003c\/p\u003e\n\u003cp\u003e                              Double Port 90\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"103\" width=\"103\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/01-Band-Images\/WebB145BC.jpg?Medium\" alt=\"Double Port 90°\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 69.3667%;\"\u003e\n\u003cp\u003e\u003cspan\u003eIgloo™ ceramic terminal covers consist of two individual ceramic parts. With a tight-fitting cap and a solid base, an Igloo will fully insulate any standard #8 or #10 terminal lug used for electrical wiring hookups. Igloos can be assembled onto any standard Mi-Plus Band with 8-32 or 10-32 screw terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Inside Diameter:\u003c\/strong\u003e 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eMinimum Width\u003c\/strong\u003e: 2-1\/2\" (63.5 mm)\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eThree types of Igloo™ bases are available:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C6\u003c\/strong\u003e — Double Port In-Line P\/N CER-101-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C7\u003c\/strong\u003e — Double Port 90° P\/N CER-101-106\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eType C8\u003c\/strong\u003e — Single Port P\/N CER-101-107\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eIgloo™ caps are available in the three screw terminal sizes:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-32\u003c\/strong\u003e — P\/N CER-102-101\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e10-24\u003c\/strong\u003e — P\/N CER-102-104\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e8-32\u003c\/strong\u003e — P\/N CER-102-105\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWhen ordering, specify the type of Igloo and the screw terminal size.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eIgloo Double Port 90° are recommended on expandable heaters with Type T3X Termination.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eIgloo Double Port In-Line will not fit on expandable heaters with Type T3X termination.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eSee reference page 1-15 for additional specifications and ordering information.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"Float75 Freeform noHeight New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float75 Freeform noHeight New50 CenterZone TitanBlock\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003e\u003c\/h5\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem\u003eCommon Applications\u003c\/em\u003e\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New100 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New100 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eAutoclaves \u0026amp; Sterilizers\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eBlow Molding Machines (Barrels \u0026amp; Heads)\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eBlown Film Dies\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eDrum Heating\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eExtrusion Die\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFluidized Beds\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFood \u0026amp; Candy Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eFood Service Warming Pots\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Float33 Freeform New50 CenterZone TitanBlock StripeGrey Float firstItemInRow\" data-mce-fragment=\"1\" blockinfo=\"Float33 Freeform New50 CenterZone TitanBlock\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eHolding Tanks\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eHot Runner Molding Bushings\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eMetallurgical Analyzation Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eOil Reclamation Systems\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePlastic Extruders\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePlastic Injection Molding Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003ePulp \u0026amp; Paper Processing Equipment\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eVending Machines\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

Tempco Mi-Plus ® Band Heaters

Product Description

Specially formulated mineral insulated tape providing excellent thermal conductivity and dielectric strength is used to insulate the nickel chrome resistance wire from the stainless steel sheath. The heater assembly is formed under pressure to a precise diameter with a thin low-mass cross section, assuring fast heat-up rates and reduced cycle times.

Specifications:

Performance Ratings

Maximum Temperature: 1400°F (760°C)

Nominal Watt Density:

  • Nozzle Bands — under 3" diameter: 30-100 W/in2 (4.7-15.5 W/cm2)
  • Barrel Bands — 3" and greater in diameter: 20-70 W/in2 (3.1-10.9 W/cm2)

Electrical Ratings

Maximum Amperage:

  • Lead Wire Termination: 12.5A
  • Screw Terminations:
  • 8-32UNF—20A
  • 10-32UNF—25A

Resistance Tolerance: +10%, –5%

Wattage Tolerance: +5%, –10%

Caution: Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

Physical Size Construction Limitations

Nominal Gap—Built-In Bracket:

  • less than 1-3/4" dia. – 1/4"
  • 1-3/4" to 2" dia. – 5/16"
  • 2" to 5" dia. – 3/8"
  • 5" to 18" dia. – 1/2"
  • greater than 18" dia. – 3/4"
  • If a larger gap is required for probes or thermocouples, specify when ordering.

Maximum Inside Diameters:

  • One-Piece –*14" (355.6 mm)
  • One-Piece Expandable – *14" (355.6 mm)
  • Two-Piece – 25" (635.0 mm)
  • Over 25" (635.0 mm) will require multiple segments. Consult TEMPCO.

* Tempco recommends two-piece construction for heaters 10" ID and greater

Standard Widths: 1" to 8" (25.4 mm to 203.2 mm)

Width Tolerance: ±3/32" (2.4 mm)

Note: If non-standard widths or tighter tolerances are required, consult Tempco.

Additional Limitations

  • For heaters less than 4" in diameter, the maximum width is twice the diameter.
  • Heaters with standard brackets are available from 1" to 8" wide, while heaters with low profile brackets are available from 1" to 6" wide.
  • 1" diameter heaters are only available in 1" and 1-1/2" widths.
  • For heaters from 10" diameter up to 25" diameter, Tempco recommends using 2-piece construction for superior clamping. Over 25" diameter, 3 or 4 segments are recommended.
  • Combinations of some minimum and maximum variations may not be available. Consult Tempco with your special requirements.
  • Post terminals are only available on heaters greater than 2-1/2" in diameter and 1-1/2" in width.

Diameter/Width Limitations

Width One-Piece Construction Expandable Construction Two-Piece Construction
Inside Diameter Inside Diameter Inside Diameter
in mm in mm in mm in mm
1  25.4 1  to  10  25.4  to  254.0 n/a n/a 3  to  25  76.2  to  635.0
1-1⁄2  38.1 1  to  14  25.4  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
2  50.8 1-1⁄2  to  14  38.1  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
2-1⁄2  63.5 1-1⁄2  to  14  38.1  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
3  76.2 1-1⁄2  to  14  38.1  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
3-1⁄2  88.9 1-3⁄4  to  14  44.5  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
4 101.6 2  to  14  50.8  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
4-1⁄2 114.3 2-1⁄4  to  14  57.2  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
5 127 2-1⁄2  to  14  63.5  to  355.6 2-1⁄2  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
5-1⁄2 139.7 2-3⁄4  to  14  69.9  to  355.6 3  to  14  63.5  to  355.6 3  to  25  76.2  to  635.0
6 152.4 3  to  14  76.2  to  355.6 3  to  14  76.2  to  355.6 3  to  25  76.2  to  635.0
6-1⁄2 165.1 3-1⁄4  to  14  82.6  to  355.6 3-1⁄4  to  14  82.6  to  355.6 3-1⁄4  to  25  82.6  to  635.0
7 177.8 3-1⁄2  to  14  88.9  to  355.6 3-1⁄2  to  14  88.9  to  355.6 3-1⁄2  to  25  88.9  to  635.0
7-1⁄2 190.5 3-3⁄4  to  14  95.3  to  355.6 3-3⁄4  to  14  95.3  to  355.6 3-3⁄4  to  25  95.3  to  635.0
8 203.2 4  to  14 101.6  to  355.6 4  to  14 101.6  to  355.6 4  to  25 101.6  to  635.0


Additional Specifications & Ordering Information:

  • See reference pages 1-2 and 1-3 for Mi-Plus design overviews.
  • See reference page 1-4 for specific Standard Specifications and Tolerance product information.
  • See reference page 1-5 for Maximum Allowable Watt Density information and calculations.

Design Features:

One Piece Band Construction

 /Tempco/Data-Assets/01-Band-Images/WebB108BC.jpg One-piece heaters provide the most heated surface area but can only be used where the entire heater can be slipped over the end of the barrel. One-piece heaters have built-in, full-width clamping bars.


Two Piece Band Construction

 /Tempco/Data-Assets/01-Band-Images/WebB110BC.jpg Two-piece construction satisfies the need for a heater that can be placed anywhere along the machine barrel and is recommended for larger diameter heaters. The two-piece construction style also provides dual voltage capability as heater halves may be wired together either in series or parallel. Two-piece heaters are rated at full voltage and 1/2 the total wattage for each half.


One Piece Expandable Band Construction

 /Tempco/Data-Assets/01-Band-Images/WebB112BC.jpg

The expandable construction style allows the heater to be opened up and placed anywhere along the machine barrel, as well as minimizes the unheated area as compared to a two-piece heater.

With two heater circuits in a common case this heater naturally lends itself to a dual voltage system. Expandable heaters are rated for each circuit at full voltage and one half of the total wattage.

Caution: It is not recommended to open a One-Piece Expandable Band Heater more than two times.


Partial Coverage Band with Built-In Brackets (2 Piece)

               /Tempco/Data-Assets/01-Band-Images/WebB250BC.jpg              

Partial coverage band heaters are required when an obstruction on the barrel would interfere with a full coverage band.  

The preferred method of construction is the 2-piece Band Heater with Built-In Brackets. The heater is bolted down to the cylinder at the ends and the built-in low thermal expansion strap pulls the heater tightly against the cylinder being heated. The standard center of hole to edge of heater dimension is 1/4".


Partial Coverage Band with Separate Strap (1 Piece)

                /Tempco/Data-Assets/01-Band-Images/WebB251BC.jpg              

The alternate method of partial coverage construction is the 1-piece Band Heater with a separate 2-piece strap.

The 2-piece strap itself is bolted at the padded ends, allowing the heater to float between the pads as illustrated below. When tightening the strap, it will pull the heater against the cylinder being heated.  The standard center of hole to edge of heater dimension is 1/4".


Clamping Options:

Type NB: Standard Built-In Clamping Strap, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB148BC.jpg              

The clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3" (76.2 mm)

Note: Standard on all Mi-Plus heaters 3" in diameter & larger

  • See reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.
  • See reference page 1-23 for Installation recommendations.


Type NS: Standard Built-In Clamping Strap, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB148BC.jpg              
Limitations
  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3" (76.2 mm)

Note: Standard on all Mi-Plus heaters 3" in diameter & larger

  • See reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.
  • See reference page 1-23 for Installation recommendations.


Type NE: Standard Built-In Clamping Strap, One Piece Expandable Band

               /Tempco/Data-Assets/01-Band-Images/WebB148BC.jpg              

The clamping brackets of the Mi-Plus Heater are formed from its outer sheath, producing a unique Built-In Strap. Clamping power is generated through barrel nuts and 1/4-20 alloy steel socket head cap screws, which are an integral part of the Built-In Strap.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3" (76.2 mm)

Note: Standard on all Mi-Plus heaters 3" in diameter & larger.

  • See reference pages 1-10, 1-11, and 1-12 for additional construction - installation information.
  • See reference page 1-23 for Installation recommendations.

Type SB: Separate Clamping Straps, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB253BC.jpg              

This option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.

  • See reference page 1-12 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance Suggested Diameter Range
8-32 .50" 1" – 3"
10-32 .56" 2" – 6"
1/4-20 .62" > 3"

 

Type SS: Separate Clamping Straps, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB253BC.jpg              

This option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.

  • See reference page 1-12 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance Suggested
Diameter Range
8-32 .50" 1" – 3"
10-32 .56" 2" – 6"
1/4-20 .62" > 3"


Type SE: Separate Clamping Straps, One Piece Expandable Band

            /Tempco/Data-Assets/01-Band-Images/WebB253BC.jpg                 

This option uses a separate strap to properly clamp the heater. A separate strap is useful when clearance is limited or there is an obstruction. Separate straps are made strictly to customer specifications.

  • See reference page 1-12 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance Suggested Diameter Range
8-32 .50" 1" – 3"
10-32 .56" 2" – 6"
1/4-20 .62" > 3"


Type LB: Low-Profile Built-In Clamping Strap, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB149BC.jpg              

When space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3" in diameter.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 1-3/8" (34.9 mm)

Note: Standard on all Mi-Plus heaters less than 3" in diameter

  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type LS: Low-Profile Built-In Clamping Strap, Two Piece Band                   

               /Tempco/Data-Assets/01-Band-Images/WebB149BC.jpg              

When space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3" in diameter.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 1-3/8" (34.9 mm)

Note: Standard on all Mi-Plus heaters less than 3" in diameter

  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type LE: Low-Profile Built-In Clamping Strap, One Piece Expandable Band 

               /Tempco/Data-Assets/01-Band-Images/WebB149BC.jpg              

When space is limited use Tempco's low profile clamping. This compact design uses 10-32 alloy socket head cap screws. Standard on all Mi-Plus heaters less than 3" in diameter.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 1-3/8" (34.9 mm)

Note: Standard on all Mi-Plus heaters less than 3" in diameter

  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type OB: Outrigger Built-In Clamping Strap, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB150BC.jpg              

This design is unique to 1" wide heaters from 1-3/8" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1" wide heaters the required clamping power.

Note: Standard on Mi-Plus heaters 1" wide and 1-3/8" in diameter and greater.

  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type OS: Outrigger Built-In Clamping Strap, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB150BC.jpg               

This design is unique to 1" wide heaters from 1-3/8" diameter and greater. Two 8-32 alloy socket head cap screws are used to give 1" wide heaters the required clamping power.

Note: Standard on Mi-Plus heaters 1" wide and 1-3/8" in diameter and greater.

  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type SL: Spring Loaded Built-In Clamping Strap, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB152.jpg              

Spring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8" in diameter and offered as an option on any heater with standard brackets.

The extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3-1/2" (88.9 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type NSL: Spring Loaded Built-In Clamping Strap, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB152.jpg              

Spring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8" in diameter and offered as an option on any heater with standard brackets.

The extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3-1/2" (88.9 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type NEL: Spring Loaded Built-In Clamping Strap, One Piece Expandable Band

               /Tempco/Data-Assets/01-Band-Images/WebB152.jpg              

Spring loaded clamping with alloy steel socket head cap screws is standard on heaters over 8" in diameter and offered as an option on any heater with standard brackets.

The extra heavy duty compression springs serve to combat thermal expansion of the heater by self adjustment, thereby ensuring excellent contact of the heater surface with the machine barrel or die. This type of clamping is also useful on heaters that are mounted vertically.

Limitations

  • Minimum Width: 1-1/2" (38.1 mm)
  • Minimum Diameter: 3-1/2" (88.9 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type WB: Weld-On Bracket, One Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebBC502.jpg              

The Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps.  Contact us with your requirements (844-862-7880).

Limitations

  • Minimum Width: 1" (25.4 mm)
  • Minimum Diameter: 1" (25.4 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance
8-32 .50"
10-32 .56"
1/4-20 .62"


Type WS: Weld-On Bracket, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebBC502.jpg              

The Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).

Limitations

  • Minimum Width: 1" (25.4 mm)
  • Minimum Diameter: 1" (25.4 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance
8-32 .50"
10-32 .56"
1/4-20 .62"


Type WE: Weld-On Bracket, One Piece Expandable Band

               /Tempco/Data-Assets/01-Band-Images/WebBC502.jpg              

The Mi-Plus is available without built-in brackets. For this option, brackets are welded onto the heater plate at user-specified locations. A weld-on bracket is useful when clearance is limited or there is an obstruction for using separate straps. Contact us with your requirements (844-862-7880).

Limitations

  • Minimum Width: 1" (25.4 mm)
  • Minimum Diameter: 1" (25.4 mm)
  • See reference page 1-13 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.
Bolt Size Clearance
8-32 .50"
10-32 .56"
1/4-20 .62"


Electrical Terminations

Type T2: Screw Terminals, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB114BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Post Terminals: 10-32 or 8-32
  • Maximum Volts: 480VAC
  • Maximum Amps: 25A (10-32) or 20A (8-32)

Ordering Information:

  • See reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12" Leads, 10" Stainless Steel Braid Ordering Information.
  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T2: Screw Terminals, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB115BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: center each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Post Terminals: 10-32 or 8-32
  • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

Ordering Information:

  • See reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12" Leads, 10" Stainless Steel Braid Ordering Information.
  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T2: Screw Terminals, One Piece Expandable Band

              /Tempco/Data-Assets/01-Band-Images/WebB117BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: center each half; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Post Terminals: 10-32 or 8-32
  • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

Ordering Information:

  • See reference pages 1-6 and 1-7 for 'Terminator Program' for Stock Mi-Plus Nozzle Band Heater Type W-2; Right-Angle Wire Braid Leads (12" Leads, 10" Stainless Steel Braid Ordering Information.
  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T3X: Screw Terminals, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB118BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: opposite the gap; across center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: With 10-32 Post Terminals — 2-1/2" (63.5 mm), With 8-32 Post Terminals — 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

Ordering Information:

  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T3X: Screw Terminals, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB119BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: opposite the gap; across center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: With 10-32 Post Terminals — 2-1/2" (63.5 mm), With 8-32 Post Terminals — 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

Ordering Information:

  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T3X: Screw Terminals, One Piece Expandable Band

              /Tempco/Data-Assets/01-Band-Images/WebB121BC.jpg              

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: opposite the gap; across center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: With 10-32 Post Terminals — 2-1/2" (63.5 mm), With 8-32 Post Terminals — 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/ 25A (10-32) or 20A (8-32) each half

Ordering Information:

  • See reference page 1-8 for Stock and Standard Mi-Plus Type T2 or T3X Screw Terminal Terminations - Ordering Information.
  • See reference page 1-14 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type T3Y: Screw Terminals, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB122BC.jpg               

The specially designed Stainless Steel Power Terminals are internally connected to the heater and are resistant to over-torquing. The screw terminals are virtually unbreakable. Secure tightening of the electrical connections is essential for safety and long heater life.

  • Standard Termination Location: next to same gap on each half; across center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: With 8-32 Post Terminals — 2" (50.8 mm), With 10-32 Post Terminals — 2-1/2" (63.5 mm)
  • Maximum Volts: 480VAC each half
  • Maximum Amps: 25A (10-32) or 20A (8-32) each half
  • See reference page 1-15 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB133BC.jpg            

The lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable.

This stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10" of stainless steel loose wire braid over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC
  • Maximum Amps: 12.5
  • See reference pages 1-15 and 1-16 for construction - installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W1: Abrasion-Resistant Straight Wire Braid Leads, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB134BC.jpg            

The lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable.

This stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10" of stainless steel loose wire braid over 12" of flexible leads.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC each half
  • Maximum Amps: 12.5A each half
  • See reference pages 1-15 and 1-16 for construction - installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W1: Abrasion-Resistant Straight Wire Braid Leads, One Piece Expandable Band

              /Tempco/Data-Assets/01-Band-Images/WebB135BC.jpg             

The lead wires exit straight out through a stainless steel eyelet. Flexible stainless steel wire braid leads are highly recommended for improved abrasion resistance. Wire braid leads offer sharp bending not possible with armor cable.

This stainless steel braid is loosely wrapped around two mica insulated lead wires rated for 842°F (450°C). The standard leads are 10" of stainless steel loose wire braid over 12" of flexible leads.

  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference pages 1-15 and 1-16 for construction - installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB123BC.jpg       

This style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments.

The stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10" of stainless steel wire braid over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; near edge of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC
  • Maximum Amps: 12.5
  • See reference page 1-16 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB125BC.jpg       

This style of wiring is the most prevalent for nozzle band heaters, as it contributes to the most flexible and space saving installation. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments.

The stainless steel braid exits parallel to the heater centerline through a low profile stainless steel cap. This cap also acts as a strain relief, guarding against excessive flexing or pulling of the lead wire. By keeping the lead wires away from the heater, less damage from high temperature contact is likely to occur. The standard leads are 10" of stainless steel wire braid over 12" of flexible leads.

  • Standard Termination Location: center of each half; near edge of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-16 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W2: Right-Angle Wire Braid Leads, 90 Degrees to Heater Diameter, One Piece Expandable Band

/Tempco/Data-Assets/01-Band-Images/WebB579.jpg
  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-16 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, One Piece Band

           /Tempco/Data-Assets/01-Band-Images/WebB124BC.jpg        

The stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments.

This low-profile termination is convenient where space limitations are a concern. The standard leads are 10" of stainless steel wire braid over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC
  • Maximum Amps: 10
  • See reference page 1-17 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type W5: Right-Angle Wire Braid Leads, 90 Degrees to heater Width, Two Piece Band

           /Tempco/Data-Assets/01-Band-Images/WebB126BC.jpg         

The stainless steel braid exits parallel to the heater surface through a low profile stainless steel cap, which also acts as a strain relief guarding against excessive flexing or pulling of the lead wire. Mica insulated lead wires rated for 842°F (450°C) with tightly wrapped stainless steel overbraid are used, providing protection in abrasive environments.

This low-profile termination is convenient where space limitations are a concern. The standard leads are 10" of stainless steel wire braid over 12" of flexible leads.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC each half
  • Maximum Amps: 10 each half
  • See reference page 1-17 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R1: Abrasion-Resistant Straight Armor Cable, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB130BC.jpg            

Stainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" lead wire.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts: 480VAC
  • Maximum Amps: 12.5
  • See reference page 1-17 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R1: Abrasion-Resistant Straight Armor Cable, Two Piece Band

               /Tempco/Data-Assets/01-Band-Images/WebB131BC.jpg         

Stainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" lead wire.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-17 for additional construction and specifications.


Type R1: Abrasion-Resistant Straight Armor Cable, One Piece Expandable Band

               /Tempco/Data-Assets/01-Band-Images/WebB132BC.jpg            

Stainless steel armor cable provides vastly superior lead wire protection in cases where abrasion is a constant problem. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" lead wire.

  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-17 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R1: Abrasion-Resistant Right Angle Armor Cable, One Piece Band

             /Tempco/Data-Assets/01-Band-Images/WebB254BC.jpg         

Stainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" of lead wire.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A
  • See reference page 1-17 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R2B: Abrasion-Resistant Right Angle Armor Cable, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB255BC.jpg         

Stainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" of lead wire.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-18 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R2B: Abrasion-Resistant Right Angle Armor Cable, One Piece Expandable Band

             /Tempco/Data-Assets/01-Band-Images/WebB256BC.jpg      

Stainless Steel Right-Angle Armor Cable will provide excellent lead wire protection. This space saving termination will give long-term abrasion protection. The lead wires are mica insulated and rated for 842°F (450°C). The standard leads are 10" of stainless steel armor cable over 12" of lead wire.

  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-18 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R2H: Abrasion-Resistant Right Angle Armor Cable for Lead Wire, One Piece Band

             /Tempco/Data-Assets/01-Band-Images/WebBC501.jpg               

High Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1-1/2" (38.1 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A
  • See reference page 1-18 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebR2H_2pcDrwng.jpg                    

High Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-18 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type R2H: Abrasion-Resistant Right Angle Armor Cable for HTL Lead Wire, One Piece Expandable Band

        /Tempco/Data-Assets/01-Band-Images/WebR2H_1PcExpndDrwng.jpg            

High Temperature Termination: 1022°F (550°C), with Special SS Right-Angle Fitting, and 3-Conductor Wire.

  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half
  • See reference page 1-18 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type C: General Purpose Terminal Box, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB136BC.jpg            

The Heavy Duty Stainless Steel Terminal Box has a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/25A

Type CA – Box only (shown)
Type CD – Box with prewired SS wire braid
Type CC – Box with prewired SS armor cable
Type CE – Box with prewired plain leads

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type C: General Purpose Terminal Box, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB137BC.jpg            

The Heavy Duty Stainless Steel Terminal Box has a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/25A each half

Type CA – Box only (shown)
Type CD – Box with prewired SS wire braid
Type CC – Box with prewired SS armor cable
Type CE – Box with prewired plain leads

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type C: General Purpose Terminal Box, One Piece Expandable Band

              /Tempco/Data-Assets/01-Band-Images/WebB138BC.jpg           

The Heavy Duty Stainless Steel Terminal Box has a 1/2" trade size knockout (actual diameter 7/8") that will accept standard armor cable connectors. To simplify installation, Mi-Plus band heaters with terminal boxes can be pre-wired.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts/Amps: 480VAC/25A each half

Type CA – Box only (shown)
Type CD – Box with prewired SS wire braid
Type CC – Box with prewired SS armor cable
Type CE – Box with prewired plain leads

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type L1: Plain Wire Leads, One Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB127BC.jpg            

Plain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10" long.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 1" (25.4 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A

Note: Plain wire leads do not offer protection against contamination or abrasion.

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type L1: Plain Wire Leads, Two Piece Band

              /Tempco/Data-Assets/01-Band-Images/WebB128BC.jpg           

Plain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10" long.

  • Standard Termination Location: center of each half; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 1" (25.4 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half

Note: Plain wire leads do not offer protection against contamination or abrasion.

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type L1: Plain Wire Leads, One Piece Expandable Band

              /Tempco/Data-Assets/01-Band-Images/WebB129BC.jpg          

Plain wire leads are available on all construction styles. The lead wires exit straight out through a stainless steel eyelet. High-temperature 842°F (450°C) mica insulated lead wire is standard. The standard lead length is 10" long.

  • Standard Termination Location: two sets of leads opposite the gap; center of width
  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 1-1/2" (38.1 mm)
  • Maximum Volts/Amps: 480VAC/12.5A each half

Note: Plain wire leads do not offer protection against contamination or abrasion.

  • See reference page 1-19 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type P1: Quick Disconnect Plugs, One Piece Band

          Type P1H                                            
Type P1H Shown        

 

 

Cup Assembly Only

Cup Assembly Only

 

Cup Assembly w/90° Plug

Cup Assembly with 90° Plug

Quick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.

The assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.

The standard abrasive protection leads are 10" of protection over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts: 250VAC           
  • Maximum Amps: 16
  • Maximum Temperature: 392°F (200°C)

P1A — Cup Assembly only
P1B — Cup Assembly with straight plug
P1C — Cup Assembly with 90° plug
P1E — Cup Assembly with straight plug and stainless steel armor cable
P1F — Cup Assembly with straight plug and stainless steel wire braid
P1H — Cup Assembly with 90° plug and stainless steel armor cable
P1J — Cup Assembly with 90° plug and stainless steel wire braid

  • See reference page 1-20 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type P1: Quick Disconnect Plugs, Two Piece Band

Type P1H
        /Tempco/Data-Assets/01-Band-Images/WebB263BC.jpg

 

  Cup Assembly Only 

Cup Assembly Only

Cup Assembly w/90° Plug

Cup Assembly with 90° Plug

Quick Disconnect Plugs are a simple, safe and quick way to apply power to a band heater installation. The combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.

The assembly is available with a straight or right-angle plug. To simplify installation, Mi-Plus band heaters with Quick Disconnects can be pre-wired with stainless steel armor or stainless steel wire braid.

The standard abrasive protection leads are 10" of protection over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts: 250VAC           
  • Maximum Amps: 16
  • Maximum Temperature: 392°F (200°C)

P1A — Cup Assembly only
P1B — Cup Assembly with straight plug
P1C — Cup Assembly with 90° plug
P1E — Cup Assembly with straight plug and stainless steel armor cable
P1F — Cup Assembly with straight plug and stainless steel wire braid
P1H — Cup Assembly with 90° plug and stainless steel armor cable
P1J — Cup Assembly with 90° plug and stainless steel wire braid

  • See reference page 1-20 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Band

     /Tempco/Data-Assets/01-Band-Images/WebB266BC.jpg

   Type P2A Shown

This lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.

To simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10" of protection over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts: 250VAC    
  • Maximum Amps: 16
  • Maximum Temperature: 572°F (300°C)

P2A — Box and Cup only
P2B — Box and Cup with straight plug
P2D — Box and Cup with straight plug and stainless steel armor cable
P2E — Box and Cup with straight plug and stainless steel wire braid

  • See reference page 1-21 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, Two Piece Band

/Tempco/Data-Assets/01-Band-Images/WebB268BC.jpg

 

Type P2A Shown

This lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.

To simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10" of protection over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts: 250VAC    
  • Maximum Amps: 16
  • Maximum Temperature: 572°F (300°C)

P2A — Box and Cup only
P2B — Box and Cup with straight plug
P2D — Box and Cup with straight plug and stainless steel armor cable
P2E — Box and Cup with straight plug and stainless steel wire braid

  • See reference page 1-21 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.


Type P2: Terminal Box and High-Temperature Quick Disconnect Straight Plug, One Piece Expandable Band


 /Tempco/Data-Assets/01-Band-Images/WebB270BC.jpg

 

Type P2A Shown

This lower profile terminal box and high temperature quick disconnect plug assembly offers a solution where clearance is a problem. This combination of plug and cup assembly along with stainless steel armor cable or stainless steel wire braid eliminates all live exposed terminals or wiring that can be a potential hazard.

To simplify installation, can be pre-wired with stainless steel armor or stainless steel wire braid. The standard abrasive protection leads are 10" of protection over 12" of flexible leads.

  • Standard Termination Location: opposite the gap; center of width
  • Minimum Inside Diameter: 3" (76.2 mm)
  • Minimum Width: 2" (50.8 mm)
  • Maximum Volts: 250VAC    
  • Maximum Amps: 16
  • Maximum Temperature: 572°F (300°C)

P2A — Box and Cup only
P2B — Box and Cup with straight plug
P2D — Box and Cup with straight plug and stainless steel armor cable
P2E — Box and Cup with straight plug and stainless steel wire braid

  • See reference page 1-21 for construction and installation information.
  • See reference page 1-23 for additional installation recommendations.

 

Additional Options

Thermocouple Coupling

           /Tempco/Data-Assets/01-Band-Images/WebB258BC.jpg          
The Thermocouple Coupling facilitates the installation of an external thermocouple with a threaded fitting. The standard location for the coupling is 90° from the gap at the center of the width. Specify without through hole for heater sensing or with through hole for load sensing.
Thread D H
1/8-27 NPT 9/16" 5/8"
1/4-20 NPT 3/4" 11/16"
3/8-18 NPT 7/8" 5/8"
M12-1.75mm 3/4" 1/2"


Thermocouple Bayonet Adapter

              /Tempco/Data-Assets/01-Band-Images/WebB259BC.jpg             

A standard Bayonet Adapter facilitates the installation of an external thermocouple with a standard bayonet cap. The standard location for the adapter is 90° from the gap.

See Temperature Sensors for a complete selection of thermocouples available from stock.


Built-In Thermocouple

 /Tempco/Data-Assets/01-Band-Images/WebPAGE1-23.jpg

A built-in thermocouple can be factory installed on Mi-Plus band heaters. ANSI type J or K thermocouples are available on Type L1, R,1 R2, W1, W2 and W5 lead wire terminations. Thermocouple junction is located inside the exit termination stamping, providing a relative heater temperature.

Thermocouple can be located in various positions on the heater. Consult Tempco with your requirements.

 

Stock Heavy-Duty Quick Disconnect Plugs and Adapters

P1P2P3P4P5

Heaters with pre-wired plugs allow quick and easy installation of the heater. These plugs can be attached to armor cable or stainless steel wire braid.

For other types of plugs, consult Tempco or specify the manufacturer's part number when ordering. See Accessories for additional Twist-Lock electrical plugs.

Reference      NEMA      Plug or Receptacle Amps Voltage

Plug Part  Number

Connectors (Female) Part Number
P1 twist lock L1-15 15A 125V EHD-102-102 EHD-103-101
P2 twist lock n/a 10A 250V EHD-102-107 EHD-103-103
15A 125V
P3 straight 5-15 15A 125V EHD-102-103 EHD-103-102
P4 twist lock L5-15 15A 125V EHD-102-113 EHD-103-104
P5 twist lock L6-15 15A 250V EHD-102-121 EHD-103-107
P6 twist lock L6-20 20A 250V EHD-102-122 EHD-103-150


Igloo Ceramic Terminal Covers for Screw Terminals

 Double Port In-Line

Double Port In-Line

                     Single Port

Single Port

                              Double Port 90°

Double Port 90°

Igloo™ ceramic terminal covers consist of two individual ceramic parts. With a tight-fitting cap and a solid base, an Igloo will fully insulate any standard #8 or #10 terminal lug used for electrical wiring hookups. Igloos can be assembled onto any standard Mi-Plus Band with 8-32 or 10-32 screw terminals.

  • Minimum Inside Diameter: 2-1/2" (63.5 mm)
  • Minimum Width: 2-1/2" (63.5 mm)

Three types of Igloo™ bases are available:

  • Type C6 — Double Port In-Line P/N CER-101-104
  • Type C7 — Double Port 90° P/N CER-101-106
  • Type C8 — Single Port P/N CER-101-107

Igloo™ caps are available in the three screw terminal sizes:

  • 10-32 — P/N CER-102-101
  • 10-24 — P/N CER-102-104
  • 8-32 — P/N CER-102-105

When ordering, specify the type of Igloo and the screw terminal size.

Note:

  • Igloo Double Port 90° are recommended on expandable heaters with Type T3X Termination.
  • Igloo Double Port In-Line will not fit on expandable heaters with Type T3X termination.
  • See reference page 1-15 for additional specifications and ordering information.

Common Applications

  • Autoclaves & Sterilizers
  • Blow Molding Machines (Barrels & Heads)
  • Blown Film Dies
  • Drum Heating
  • Extrusion Die
  • Fluidized Beds
  • Food & Candy Extruders
  • Food Service Warming Pots
  • Holding Tanks
  • Hot Runner Molding Bushings
  • Metallurgical Analyzation Equipment
  • Oil Reclamation Systems
  • Plastic Extruders
  • Plastic Injection Molding Machines
  • Pulp & Paper Processing Equipment
  • Vending Machines
Sku: MPP50101