{"id":7450574586075,"title":"Tempco Hi-Density Miniature Cartridge Heaters","handle":"tempco-hi-density-miniature-cartridge-heaters","description":"\u003cp data-mce-fragment=\"1\"\u003eThe small size of the heater provides lower internal temperatures and faster heating response times.  Swaged construction allows for higher watt densities, higher operating temperatures, and longer heater life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe standard sheath material is 304 Stainless Steel which provides good thermal conductivity and resistance to corrosion and scaling. The welded end disc made from the same material as the sheath provides a positive seal against moisture and other contaminants. Grade “A” Nickel-Chrome resistance wire precisely wound on a high purity magnesium oxide core places the resistance wire as close to the inside of the sheath as possible. A high purity Magnesium Oxide (MgO) powder is used to fill all remaining space inside the sheath. Heater is then swaged, which compacts the magnesium oxide grains into a solid mass.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe standard termination is a Teflon\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eplug with Teflon\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eleads (Type M3) with internally connected leads that provide flexibility and allow the leads to bend sharply as they exit the heater.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1200°F (649°C)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Watt Density:\u003c\/strong\u003e 100-200 W\/in\u003csup\u003e2\u003c\/sup\u003e (15.5-31 W\/cm\u003csup\u003e2\u003c\/sup\u003e) depending on operating temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eSheath Material\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStandard:\u003c\/strong\u003e\u003cspan\u003e Type 304 Stainless Steel\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOptional (1\/8 in Heaters Only):\u003c\/strong\u003e\u003cspan\u003e Inconel 600\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum operating temperature and the life expectancy of a cartridge heater is dependent on two main factors:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum recommended sheath temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum ambient temperature for the termination selected\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS if you require a recommendation for your application (844) 862-7880.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eDimensional Specifications\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\"\u003eNominal Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003e1\/8\"\u003c\/th\u003e\n\u003cth colspan=\"2\" rowspan=\"1\"\u003e5\/32\"\u003c\/th\u003e\n\u003cth colspan=\"2\" rowspan=\"1\"\u003e3\/16\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eActual Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.122\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.153\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.89\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.184\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eDiameter Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±.002 (-0.051)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMinimum Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e1.25 (31.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e12 (305)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003eLength Tolerance Heaters up to 3.5\"\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(89 mm) long\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±3\/32 (2.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003eLength Tolerance Heaters over 3.5\"\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(89 mm) long\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±3% of Sheath Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Diameter\u003c\/th\u003e\n\u003cth\u003e1\/8\"\u003c\/th\u003e\n\u003cth\u003e5\/32\"\u003c\/th\u003e\n\u003cth\u003e3\/16\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Wattage at 120V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Wattage at 240V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eWattage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e+10,-15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eResistance Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e+15,-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTermination Location\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eSingle-Ended Straight Termination\u003c\/em\u003e\u003c\/h4\u003e\n\u003cbr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC091.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC091.jpg?Small\" width=\"254\" height=\"187\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Electrical Termination is located at one end of the heater and exits straight out from the heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cem\u003eType M3: Teflon \u003c\/em\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cem\u003eEnd Plug Seal with Teflon \u003c\/em\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cem\u003eLeads\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard Termination for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003eHi-Density Miniature Cartridge Heaters\u003c\/em\u003e\u003c\/strong\u003e.  A moisture resistant Teflon® seal is swaged in during the manufacturing process with Teflon® insulated lead wire.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/2\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e24 gage Teflon® insulated leads temperature rating: 392°F (200°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMoisture resistant swaged Teflon® seal.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType N: \u003c\/em\u003e\u003cem data-mce-fragment=\"1\"\u003eExternal Pins with \u003c\/em\u003e\u003cem data-mce-fragment=\"1\"\u003eLeads\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"353\" height=\"233\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 470px;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 470px;\"\u003e\n\u003cp\u003e\u003cem\u003eFlexible stranded lead wires have fiberglass insulation and are connected to 1-1\/4\" (32 mm) long solid conductors. Silicone rubber coated fiberglass sleeving insulates the pin\/lead wire connection.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e24 gage ultralead leads temperature rating: 482°F (250°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eLeads externally crimped to nickel pins\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType F: Internally Connected Flexible Leads\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"223\" width=\"303\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe fiberglass lead wires are internally connected to the terminal pins. This lead termination provides flexibility, permitting the lead wires to be sharply bent as they exit the heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/2\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eHigh temperature fiberglass leads temperature rating: 842°F (450°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType W: Wire Braided Leads\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"223\" width=\"383\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C586_lighter_W_Dim.jpg\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C586_lighter_W_Dim.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eStainless steel braid over fiberglass leads offers sharp bending not possible with armor cable, as well as abrasion protection.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard lead wire temperature rating: 842°F (450°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) cable over 12\" (305 mm) leads. Specify longer leads or cable.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType C1B: Stainless Steel Armor Cable, Mechanically Fastened\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" alt=\"Type C1B Dimensions\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C613_Dim.jpg?Medium\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C613_Dim.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eArmor cable provides the maximum in protection for abrasive, jagged environments. The coupling between the cartridge and the armor cable is mechanically fastened.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard fiberglass lead wire temperature rating: 482°F (250°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) cable over 12\" (305 mm) leads. Specify longer leads or cable.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eRequest Other Electrical Termination\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan\u003ePlease contact IHS for addition electrical termination options (844) 862-7880!\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSheath Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType R4: Bent Cartridge\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" alt=\"Type R4 Dimensions\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C614_Dim.jpg?Medium\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C614_Dim.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe heater sheath is bent up to 90°. The bend is through a required unheated section. The standard sheath extension past the bend is 1\". Specify when ordering if a longer sheath is required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eContact IHS for additional bend radius details.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType LR: Location Ring\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C615_Dim.jpg?Medium\" alt=\"Type LR Dimensions\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C615_Dim.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA locating ring can be attached to the heater to aid in positioning the heater for the application. The default position of the ring is 1\/4\" from the lead end. Specify the position of the ring when ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSensor Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType TJ1 and TK1: Grounded at Disc End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath at the disc end and packed with MgO. The concave end disc is filled with silver solder and ground flat. When inserted into a flat end blind hole, it will provide fast responsive temperature readings. Widely used in Hot Runner mold probes.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ1 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK1 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; width: 274.094px;\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; width: 124.391px;\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center; width: 128.734px;\"\u003ePositive\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 139.359px;\"\u003eNegative\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 54.3281px;\"\u003e°F\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 64.0625px;\"\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 128.734px;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 139.359px;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 54.3281px;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 64.0625px;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 128.734px;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 139.359px;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 54.3281px;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 64.0625px;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType TJ2 and TK2: Ungrounded at Disc End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"187\" width=\"254\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is ungrounded, located at the end of the heater section, 1\/8\" behind the end disc and packed with MgO. Only provides reference temperature reading of the part being heated – slower response.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ2 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK2 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" rowspan=\"2\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePositive\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eNegative\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e°F\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType TJ3 and TK3: Ungrounded at Center\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is ungrounded and is located in the center of the length and diameter of the cartridge heater. It provides internal temperature readings of the heater core. Generally used for research applications and is not recommended for controlling process temperatures.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eTJ3 Type J thermocouple\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK3 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive\u003c\/th\u003e\n\u003cth\u003eNegative\u003c\/th\u003e\n\u003cth\u003e°F\u003c\/th\u003e\n\u003cth\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType TJ4 and TK4: Grounded at Center\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 191px;\"\u003e\n\u003ctd style=\"text-align: center; height: 191px;\"\u003e\n\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg?Small\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.2969px;\"\u003e\n\u003ctd style=\"height: 30.2969px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath in a 1\/2\" unheated section located in the center of the cartridge length unless otherwise specified. It provides good temperature readings with quick response.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ4 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK4 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eConductor Characteristics\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eTemperature Ranged\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePositive\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eNegative\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e°F\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e°C\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType TJ5 and TK5: Grounded at Lead End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath at the lead end. A minimum of 3\/8\" of cold section is required. It provides good temperature readings with quick response.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ5 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK5 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003e1\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cem\u003e0\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive\u003c\/th\u003e\n\u003cth\u003eNegative\u003c\/th\u003e\n\u003cth\u003e°F\u003c\/th\u003e\n\u003cth\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePower Variations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType DW: Distributed Wattage\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e           \u003cimg data-mce-fragment=\"1\" height=\"238\" width=\"323\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eCartridge heaters can be designed to vary the wattage along the length of the heater. Specify number of zones and the required watts and length per zone starting from the disk end. Leads can be connected externally or internally. Picture shows a heater with Type N externally connected leads. Heaters with other terminations may require a longer cold section at the lead end.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eType GJ: Grounded Element Winding\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" height=\"324\" width=\"324\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor DC applications where the electrical circuit is negative grounded, the cartridge heater can be designed with one side of the element winding grounded to the sheath and a single lead wire exiting the cartridge heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003eType GL: Ground Lead\/Sheath\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\" width=\"353\" height=\"353\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor those applications requiring a separate ground lead attached to the cartridge heater sheath. Standard ground lead wire is a 10\" long insulated stranded conductor. Optional insulated and color coded leads are available.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType TM: Thermistor\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eTempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice. \u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-58 for Thermocouple Specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-60 for additional Internal Sensor and Control Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType RD: RTD Temperature Sensor\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eTempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eFor thermocouples see reference page 2-58.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-60 for additional Internal Sensor and Control Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eStandard Electrical Tests \u0026amp; Optional Test Reports\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eStandard Electrical Tests and Optional Test Reports\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e1. Resistance test — measures ohms at room temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e2. IR (insulation resistance) test — measures the insulation resistance to the flow of current. Standard test is done at 500VDC.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e3. Hipot (high potential) test — a high voltage is applied between a product's current carrying conductors and its metallic enclosure to verify that the insulation is sufficient to protect the operator from electrical shock.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e4. Leakage current test — measures the current that flows from any conductive part to ground.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e5. Heaters can be serialized and test reports can be sent with each shipment if required. Contact IHS with your requirements (844) 862-7880.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDie Penetrant Test\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eThis non-destructive testing can detect imperfections in weld joints. For critical applications, each individual heater’s weld joints by end cap and fittings can be tested. Certified test reports will be sent with each shipment. Consult IHS for details (844) 862-7880. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHydrostatic Pressure Test\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eCartridge heaters with attached pipe fittings can be pressure tested to your specifications. Our testing capabilities can ensure that your products meet your exact specifications. Contact IHS with your requirements (844) 862-7880. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlastic Extruders\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHot Runner Molds\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHot Stamping\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMedical Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePackaging Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMolds\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAerospace\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSealing Bags\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSemiconductor\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlastic Molding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eShoe Machinery\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFood Processing\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHeating Gases and Liquids\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGlue Guns\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLaminating Presses\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlatens\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScientific Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFood Service Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\n\u003cdiv class=\"dataTables_scrollHeadInner\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollBody\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollFoot\"\u003e\n\u003cdiv class=\"dataTables_scrollFootInner\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2021-11-22T08:46:31-05:00","created_at":"2021-11-18T10:17:32-05:00","vendor":"Tempco","type":"Replacement Parts","tags":["Electronics","Food \u0026 Beverage","Heaters","Manufacturing","Medical \u0026 Pharmaceutical Production","Plastic Fabrication","Process Heat","Replacement Parts","Tempco"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42073631883483,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HDC19100","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Tempco Hi-Density Miniature Cartridge Heaters","public_title":null,"options":["Default Title"],"price":0,"weight":2268,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters.png?v=1637248653","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-1.png?v=1637248653","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-2.png?v=1637248654","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-90.png?v=1637613798"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters.png?v=1637248653","options":["Title"],"media":[{"alt":null,"id":28672926744795,"position":1,"preview_image":{"aspect_ratio":1.0,"height":720,"width":720,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters.png?v=1637248653"},"aspect_ratio":1.0,"height":720,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters.png?v=1637248653","width":720},{"alt":null,"id":28672926777563,"position":2,"preview_image":{"aspect_ratio":0.84,"height":827,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-1.png?v=1637248653"},"aspect_ratio":0.84,"height":827,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-1.png?v=1637248653","width":695},{"alt":null,"id":28672926810331,"position":3,"preview_image":{"aspect_ratio":0.831,"height":834,"width":693,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-2.png?v=1637248654"},"aspect_ratio":0.831,"height":834,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-2.png?v=1637248654","width":693},{"alt":null,"id":28728650367195,"position":4,"preview_image":{"aspect_ratio":0.838,"height":831,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-90.png?v=1637613798"},"aspect_ratio":0.838,"height":831,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoHi-DensityMiniCartridgeHeaters-90.png?v=1637613798","width":696}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-mce-fragment=\"1\"\u003eThe small size of the heater provides lower internal temperatures and faster heating response times.  Swaged construction allows for higher watt densities, higher operating temperatures, and longer heater life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe standard sheath material is 304 Stainless Steel which provides good thermal conductivity and resistance to corrosion and scaling. The welded end disc made from the same material as the sheath provides a positive seal against moisture and other contaminants. Grade “A” Nickel-Chrome resistance wire precisely wound on a high purity magnesium oxide core places the resistance wire as close to the inside of the sheath as possible. A high purity Magnesium Oxide (MgO) powder is used to fill all remaining space inside the sheath. Heater is then swaged, which compacts the magnesium oxide grains into a solid mass.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe standard termination is a Teflon\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eplug with Teflon\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eleads (Type M3) with internally connected leads that provide flexibility and allow the leads to bend sharply as they exit the heater.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003ePerformance Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 1200°F (649°C)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMaximum Watt Density:\u003c\/strong\u003e 100-200 W\/in\u003csup\u003e2\u003c\/sup\u003e (15.5-31 W\/cm\u003csup\u003e2\u003c\/sup\u003e) depending on operating temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eSheath Material\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eStandard:\u003c\/strong\u003e\u003cspan\u003e Type 304 Stainless Steel\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eOptional (1\/8 in Heaters Only):\u003c\/strong\u003e\u003cspan\u003e Inconel 600\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum operating temperature and the life expectancy of a cartridge heater is dependent on two main factors:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum recommended sheath temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe maximum ambient temperature for the termination selected\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS if you require a recommendation for your application (844) 862-7880.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eDimensional Specifications\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\"\u003eNominal Diameter\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003e1\/8\"\u003c\/th\u003e\n\u003cth colspan=\"2\" rowspan=\"1\"\u003e5\/32\"\u003c\/th\u003e\n\u003cth colspan=\"2\" rowspan=\"1\"\u003e3\/16\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003cth\u003ein\u003c\/th\u003e\n\u003cth\u003e(mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eActual Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.122\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.10\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.153\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.89\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.184\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eDiameter Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±.002 (-0.051)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMinimum Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e1.25 (31.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e12 (305)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003eLength Tolerance Heaters up to 3.5\"\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(89 mm) long\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±3\/32 (2.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cstrong\u003eLength Tolerance Heaters over 3.5\"\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(89 mm) long\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\" rowspan=\"1\"\u003e±3% of Sheath Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eElectrical Ratings\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Diameter\u003c\/th\u003e\n\u003cth\u003e1\/8\"\u003c\/th\u003e\n\u003cth\u003e5\/32\"\u003c\/th\u003e\n\u003cth\u003e3\/16\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Wattage at 120V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eMaximum Wattage at 240V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eWattage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e+10,-15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eResistance Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\" rowspan=\"1\"\u003e+15,-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTermination Location\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eSingle-Ended Straight Termination\u003c\/em\u003e\u003c\/h4\u003e\n\u003cbr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan\u003e\u003cimg alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC091.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC091.jpg?Small\" width=\"254\" height=\"187\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe Electrical Termination is located at one end of the heater and exits straight out from the heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eElectrical Terminations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cem\u003eType M3: Teflon \u003c\/em\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cem\u003eEnd Plug Seal with Teflon \u003c\/em\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cem\u003eLeads\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_M.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard Termination for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003eHi-Density Miniature Cartridge Heaters\u003c\/em\u003e\u003c\/strong\u003e.  A moisture resistant Teflon® seal is swaged in during the manufacturing process with Teflon® insulated lead wire.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/2\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e24 gage Teflon® insulated leads temperature rating: 392°F (200°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMoisture resistant swaged Teflon® seal.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType N: \u003c\/em\u003e\u003cem data-mce-fragment=\"1\"\u003eExternal Pins with \u003c\/em\u003e\u003cem data-mce-fragment=\"1\"\u003eLeads\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"353\" height=\"233\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 470px;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_N.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 470px;\"\u003e\n\u003cp\u003e\u003cem\u003eFlexible stranded lead wires have fiberglass insulation and are connected to 1-1\/4\" (32 mm) long solid conductors. Silicone rubber coated fiberglass sleeving insulates the pin\/lead wire connection.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e24 gage ultralead leads temperature rating: 482°F (250°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eLeads externally crimped to nickel pins\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType F: Internally Connected Flexible Leads\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"223\" width=\"303\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC586_lighter_F.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe fiberglass lead wires are internally connected to the terminal pins. This lead termination provides flexibility, permitting the lead wires to be sharply bent as they exit the heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/2\" unheated section at lead end is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eHigh temperature fiberglass leads temperature rating: 842°F (450°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) leads. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType W: Wire Braided Leads\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"223\" width=\"383\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C586_lighter_W_Dim.jpg\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C586_lighter_W_Dim.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eStainless steel braid over fiberglass leads offers sharp bending not possible with armor cable, as well as abrasion protection.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard lead wire temperature rating: 842°F (450°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) cable over 12\" (305 mm) leads. Specify longer leads or cable.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType C1B: Stainless Steel Armor Cable, Mechanically Fastened\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" alt=\"Type C1B Dimensions\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C613_Dim.jpg?Medium\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C613_Dim.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eArmor cable provides the maximum in protection for abrasive, jagged environments. The coupling between the cartridge and the armor cable is mechanically fastened.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum 1\/4\" unheated section is required.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard fiberglass lead wire temperature rating: 482°F (250°C)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eStandard 10\" (254 mm) cable over 12\" (305 mm) leads. Specify longer leads or cable.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eRequest Other Electrical Termination\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan\u003ePlease contact IHS for addition electrical termination options (844) 862-7880!\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSheath Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType R4: Bent Cartridge\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" alt=\"Type R4 Dimensions\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C614_Dim.jpg?Medium\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C614_Dim.jpg?Medium\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe heater sheath is bent up to 90°. The bend is through a required unheated section. The standard sheath extension past the bend is 1\". Specify when ordering if a longer sheath is required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eContact IHS for additional bend radius details.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType LR: Location Ring\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C615_Dim.jpg?Medium\" alt=\"Type LR Dimensions\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/C615_Dim.jpg?Medium\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eA locating ring can be attached to the heater to aid in positioning the heater for the application. The default position of the ring is 1\/4\" from the lead end. Specify the position of the ring when ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-11 for Standard Termination and Sheath Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSensor Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType TJ1 and TK1: Grounded at Disc End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg\" width=\"353\" height=\"260\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC049.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath at the disc end and packed with MgO. The concave end disc is filled with silver solder and ground flat. When inserted into a flat end blind hole, it will provide fast responsive temperature readings. Widely used in Hot Runner mold probes.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ1 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK1 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; width: 274.094px;\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\" style=\"text-align: center; width: 124.391px;\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center; width: 128.734px;\"\u003ePositive\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 139.359px;\"\u003eNegative\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 54.3281px;\"\u003e°F\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 64.0625px;\"\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 128.734px;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 139.359px;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 54.3281px;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 64.0625px;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 59.5156px;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 128.734px;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 139.359px;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 54.3281px;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 64.0625px;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType TJ2 and TK2: Ungrounded at Disc End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" height=\"187\" width=\"254\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC050.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is ungrounded, located at the end of the heater section, 1\/8\" behind the end disc and packed with MgO. Only provides reference temperature reading of the part being heated – slower response.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ2 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK2 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" rowspan=\"2\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth style=\"text-align: center;\" colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003ePositive\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eNegative\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e°F\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType TJ3 and TK3: Ungrounded at Center\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC051.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eThe thermocouple junction is ungrounded and is located in the center of the length and diameter of the cartridge heater. It provides internal temperature readings of the heater core. Generally used for research applications and is not recommended for controlling process temperatures.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eTJ3 Type J thermocouple\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK3 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Consult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive\u003c\/th\u003e\n\u003cth\u003eNegative\u003c\/th\u003e\n\u003cth\u003e°F\u003c\/th\u003e\n\u003cth\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003eType TJ4 and TK4: Grounded at Center\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 191px;\"\u003e\n\u003ctd style=\"text-align: center; height: 191px;\"\u003e\n\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC052.jpg?Small\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.2969px;\"\u003e\n\u003ctd style=\"height: 30.2969px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath in a 1\/2\" unheated section located in the center of the cartridge length unless otherwise specified. It provides good temperature readings with quick response.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ4 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK4 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e10\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eConductor Characteristics\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eTemperature Ranged\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePositive\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eNegative\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e°F\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e°C\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType TJ5 and TK5: Grounded at Lead End\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg?Small\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg\" width=\"254\" height=\"187\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC053.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eThe thermocouple junction is grounded to the sheath at the lead end. A minimum of 3\/8\" of cold section is required. It provides good temperature readings with quick response.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTJ5 Type J thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTK5 Type K thermocouple\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eMinimum sheath length: 3\" for 1\/4\", 3\/8\" and 1\/2\" diameter. 4\" for 5\/8\" and 3\/4\" diameter.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003e1\u003c\/em\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cem\u003e0\" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eSee reference page 2-58 for additional thermocouple control recommendations.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNote: \u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003eConsult IHS for additional thermocouple types.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"text-align: center;\"\u003e\u003cstrong\u003eANSI Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003cth colspan=\"2\"\u003eConductor Characteristics\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eTemperature Ranged\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive\u003c\/th\u003e\n\u003cth\u003eNegative\u003c\/th\u003e\n\u003cth\u003e°F\u003c\/th\u003e\n\u003cth\u003e°C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIron (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eConstantan (Non-Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 1400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eChrome (Non-Magnetic)_\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAlumel (Magnetic)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 2300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-17 to 1260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePower Variations\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType DW: Distributed Wattage\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e           \u003cimg data-mce-fragment=\"1\" height=\"238\" width=\"323\" alt=\"\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg?Small\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebC072.jpg?Small\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eCartridge heaters can be designed to vary the wattage along the length of the heater. Specify number of zones and the required watts and length per zone starting from the disk end. Leads can be connected externally or internally. Picture shows a heater with Type N externally connected leads. Heaters with other terminations may require a longer cold section at the lead end.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eType GJ: Grounded Element Winding\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" height=\"324\" width=\"324\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor DC applications where the electrical circuit is negative grounded, the cartridge heater can be designed with one side of the element winding grounded to the sheath and a single lead wire exiting the cartridge heater.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cem\u003eType GL: Ground Lead\/Sheath\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\" width=\"353\" height=\"353\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/02-Cartridge-Images\/WebLD60.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eFor those applications requiring a separate ground lead attached to the cartridge heater sheath. Standard ground lead wire is a 10\" long insulated stranded conductor. Optional insulated and color coded leads are available.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. \u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-59 for additional Power Variation Specifications and Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - US Measures and Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_US_Measures.pdf?v=1640092972%20\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\" title=\"Tempco Hi-Density Miniature Cartridge Heaters - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Hi-Density_Mini_Cartridge_Heater_Order_List_-_Metric_Measures.pdf?v=1640092972%20\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Options\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eType TM: Thermistor\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cem\u003eTempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice. \u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-58 for Thermocouple Specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-60 for additional Internal Sensor and Control Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eType RD: RTD Temperature Sensor\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eTempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eFor thermocouples see reference page 2-58.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 2-60 for additional Internal Sensor and Control Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eStandard Electrical Tests \u0026amp; Optional Test Reports\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003eStandard Electrical Tests and Optional Test Reports\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e1. Resistance test — measures ohms at room temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e2. IR (insulation resistance) test — measures the insulation resistance to the flow of current. Standard test is done at 500VDC.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e3. Hipot (high potential) test — a high voltage is applied between a product's current carrying conductors and its metallic enclosure to verify that the insulation is sufficient to protect the operator from electrical shock.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e4. Leakage current test — measures the current that flows from any conductive part to ground.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e5. Heaters can be serialized and test reports can be sent with each shipment if required. Contact IHS with your requirements (844) 862-7880.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eDie Penetrant Test\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eThis non-destructive testing can detect imperfections in weld joints. For critical applications, each individual heater’s weld joints by end cap and fittings can be tested. Certified test reports will be sent with each shipment. Consult IHS for details (844) 862-7880. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eHydrostatic Pressure Test\u003c\/em\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eCartridge heaters with attached pipe fittings can be pressure tested to your specifications. Our testing capabilities can ensure that your products meet your exact specifications. Contact IHS with your requirements (844) 862-7880. \u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlastic Extruders\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHot Runner Molds\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHot Stamping\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMedical Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePackaging Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMolds\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAerospace\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSealing Bags\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSemiconductor\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlastic Molding\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eShoe Machinery\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFood Processing\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHeating Gases and Liquids\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGlue Guns\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLaminating Presses\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePlatens\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScientific Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFood Service Equipment\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollHead\"\u003e\n\u003cdiv class=\"dataTables_scrollHeadInner\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollBody\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"dataTables_scrollFoot\"\u003e\n\u003cdiv class=\"dataTables_scrollFootInner\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e"}

Tempco Hi-Density Miniature Cartridge Heaters

Product Description

The small size of the heater provides lower internal temperatures and faster heating response times.  Swaged construction allows for higher watt densities, higher operating temperatures, and longer heater life.

The standard sheath material is 304 Stainless Steel which provides good thermal conductivity and resistance to corrosion and scaling. The welded end disc made from the same material as the sheath provides a positive seal against moisture and other contaminants. Grade “A” Nickel-Chrome resistance wire precisely wound on a high purity magnesium oxide core places the resistance wire as close to the inside of the sheath as possible. A high purity Magnesium Oxide (MgO) powder is used to fill all remaining space inside the sheath. Heater is then swaged, which compacts the magnesium oxide grains into a solid mass.

The standard termination is a Teflon® plug with Teflon® leads (Type M3) with internally connected leads that provide flexibility and allow the leads to bend sharply as they exit the heater.

Specifications:

Performance Ratings

Maximum Temperature: 1200°F (649°C)

Maximum Watt Density: 100-200 W/in2 (15.5-31 W/cm2) depending on operating temperature.

Sheath Material

Standard: Type 304 Stainless Steel

Optional (1/8 in Heaters Only): Inconel 600

The maximum operating temperature and the life expectancy of a cartridge heater is dependent on two main factors:

  1. The maximum recommended sheath temperature
  2. The maximum ambient temperature for the termination selected

Note: Consult IHS if you require a recommendation for your application (844) 862-7880.

Dimensional Specifications

Nominal Diameter 1/8" 5/32" 3/16"
in (mm) in (mm) in (mm)
Actual Diameter 0.122 3.10 0.153 3.89 0.184 4.67
Diameter Tolerance ±.002 (-0.051)
Minimum Length 1.25 (31.8)
Maximum Length 12 (305)
Length Tolerance Heaters up to 3.5"
(89 mm) long
±3/32 (2.4)
Length Tolerance Heaters over 3.5"
(89 mm) long
±3% of Sheath Length

Electrical Ratings

Nominal Diameter 1/8" 5/32" 3/16"
Maximum Voltage 240
Maximum Amperage 3.0
Maximum Wattage at 120V 360
Maximum Wattage at 240V 720
Wattage Tolerance +10,-15%
Resistance Tolerance +15,-10%

Termination Location

Single-Ended Straight Termination


/Tempco/Data-Assets/02-Cartridge-Images/WebC091.jpg

The Electrical Termination is located at one end of the heater and exits straight out from the heater.

Electrical Terminations

Type M3: Teflon ® End Plug Seal with Teflon ® Leads

 /Tempco/Data-Assets/02-Cartridge-Images/WebC586_lighter_M.jpg

Standard Termination for Hi-Density Miniature Cartridge Heaters.  A moisture resistant Teflon® seal is swaged in during the manufacturing process with Teflon® insulated lead wire.

  • Minimum 1/2" unheated section at lead end is required.
  • 24 gage Teflon® insulated leads temperature rating: 392°F (200°C)
  • Moisture resistant swaged Teflon® seal.
  • Standard 10" (254 mm) leads. Specify longer leads.
  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Type N: External Pins with Leads

 /Tempco/Data-Assets/02-Cartridge-Images/WebC586_lighter_N.jpg

Flexible stranded lead wires have fiberglass insulation and are connected to 1-1/4" (32 mm) long solid conductors. Silicone rubber coated fiberglass sleeving insulates the pin/lead wire connection.

  • Minimum 1/4" unheated section at lead end is required.
  • 24 gage ultralead leads temperature rating: 482°F (250°C)
  • Leads externally crimped to nickel pins
  • Standard 10" (254 mm) leads. Specify longer leads.
  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Type F: Internally Connected Flexible Leads

 /Tempco/Data-Assets/02-Cartridge-Images/WebC586_lighter_F.jpg

The fiberglass lead wires are internally connected to the terminal pins. This lead termination provides flexibility, permitting the lead wires to be sharply bent as they exit the heater.

  • Minimum 1/2" unheated section at lead end is required.
  • High temperature fiberglass leads temperature rating: 842°F (450°C)
  • Standard 10" (254 mm) leads. Specify longer leads.
  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Type W: Wire Braided Leads

 

Stainless steel braid over fiberglass leads offers sharp bending not possible with armor cable, as well as abrasion protection.

  • Minimum 1/4" unheated section is required.
  • Standard lead wire temperature rating: 842°F (450°C)
  • Standard 10" (254 mm) cable over 12" (305 mm) leads. Specify longer leads or cable.
  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Type C1B: Stainless Steel Armor Cable, Mechanically Fastened

Type C1B Dimensions 

Armor cable provides the maximum in protection for abrasive, jagged environments. The coupling between the cartridge and the armor cable is mechanically fastened.

  • Minimum 1/4" unheated section is required.
  • Standard fiberglass lead wire temperature rating: 482°F (250°C)
  • Standard 10" (254 mm) cable over 12" (305 mm) leads. Specify longer leads or cable.
  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Request Other Electrical Termination

Please contact IHS for addition electrical termination options (844) 862-7880!

Sheath Options

Type R4: Bent Cartridge

Type R4 Dimensions 

The heater sheath is bent up to 90°. The bend is through a required unheated section. The standard sheath extension past the bend is 1". Specify when ordering if a longer sheath is required.

  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

Note: Contact IHS for additional bend radius details.

Type LR: Location Ring

 Type LR Dimensions

A locating ring can be attached to the heater to aid in positioning the heater for the application. The default position of the ring is 1/4" from the lead end. Specify the position of the ring when ordering.

  • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
  • See reference page 2-11 for Standard Termination and Sheath Specifications and Information.
  • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures. 

 

Sensor Options

Type TJ1 and TK1: Grounded at Disc End

 /Tempco/Data-Assets/02-Cartridge-Images/WebC049.jpg

The thermocouple junction is grounded to the sheath at the disc end and packed with MgO. The concave end disc is filled with silver solder and ground flat. When inserted into a flat end blind hole, it will provide fast responsive temperature readings. Widely used in Hot Runner mold probes.

  • TJ1 Type J thermocouple
  • TK1 Type K thermocouple
  • Minimum sheath length: 3" for 1/4", 3/8" and 1/2" diameter. 4" for 5/8" and 3/4" diameter.
  • 10" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.
  • See reference page 2-58 for additional thermocouple control recommendations.

Note: Consult IHS for additional thermocouple types.

ANSI Code Conductor Characteristics Temperature Ranged
Positive Negative °F °C
J Iron (Magnetic) Constantan (Non-Magnetic) 0 to 1400 -17 to 760
K Chrome (Non-Magnetic)_ Alumel (Magnetic) 0 to 2300 -17 to 1260

Type TJ2 and TK2: Ungrounded at Disc End

 /Tempco/Data-Assets/02-Cartridge-Images/WebC050.jpg

The thermocouple junction is ungrounded, located at the end of the heater section, 1/8" behind the end disc and packed with MgO. Only provides reference temperature reading of the part being heated – slower response.

  • TJ2 Type J thermocouple
  • TK2 Type K thermocouple
  • Minimum sheath length: 3" for 1/4", 3/8" and 1/2" diameter. 4" for 5/8" and 3/4" diameter.
  • 10" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.
  • See reference page 2-58 for additional thermocouple control recommendations.

Note: Consult IHS for additional thermocouple types.

ANSI Code Conductor Characteristics Temperature Ranged
Positive Negative °F °C
J Iron (Magnetic) Constantan (Non-Magnetic) 0 to 1400 -17 to 760
K Chrome (Non-Magnetic)_ Alumel (Magnetic) 0 to 2300 -17 to 1260

Type TJ3 and TK3: Ungrounded at Center

 /Tempco/Data-Assets/02-Cartridge-Images/WebC051.jpg

The thermocouple junction is ungrounded and is located in the center of the length and diameter of the cartridge heater. It provides internal temperature readings of the heater core. Generally used for research applications and is not recommended for controlling process temperatures.

  • TJ3 Type J thermocouple
  • TK3 Type K thermocouple
  • Minimum sheath length: 3" for 1/4", 3/8" and 1/2" diameter. 4" for 5/8" and 3/4" diameter.
  • 10" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.
  • See reference page 2-58 for additional thermocouple control recommendations.

    Note: Consult IHS for additional thermocouple types.

    ANSI Code Conductor Characteristics Temperature Ranged
    Positive Negative °F °C
    J Iron (Magnetic) Constantan (Non-Magnetic) 0 to 1400 -17 to 760
    K Chrome (Non-Magnetic)_ Alumel (Magnetic) 0 to 2300 -17 to 1260

    Type TJ4 and TK4: Grounded at Center

    /Tempco/Data-Assets/02-Cartridge-Images/WebC052.jpg 

    The thermocouple junction is grounded to the sheath in a 1/2" unheated section located in the center of the cartridge length unless otherwise specified. It provides good temperature readings with quick response.

    • TJ4 Type J thermocouple
    • TK4 Type K thermocouple
    • Minimum sheath length: 3" for 1/4", 3/8" and 1/2" diameter. 4" for 5/8" and 3/4" diameter.
    • 10" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.
    • See reference page 2-58 for additional thermocouple control recommendations.

    Note: Consult IHS for additional thermocouple types.

    ANSI Code Conductor Characteristics Temperature Ranged
    Positive Negative °F °C
    J Iron (Magnetic) Constantan (Non-Magnetic) 0 to 1400 -17 to 760
    K Chrome (Non-Magnetic)_ Alumel (Magnetic) 0 to 2300 -17 to 1260

    Type TJ5 and TK5: Grounded at Lead End

     /Tempco/Data-Assets/02-Cartridge-Images/WebC053.jpg

    The thermocouple junction is grounded to the sheath at the lead end. A minimum of 3/8" of cold section is required. It provides good temperature readings with quick response.

    • TJ5 Type J thermocouple
    • TK5 Type K thermocouple
    • Minimum sheath length: 3" for 1/4", 3/8" and 1/2" diameter. 4" for 5/8" and 3/4" diameter.
    • 10" leads are standard for both heater and thermocouple. Leads are internally connected. Specify longer leads.
    • See reference page 2-58 for additional thermocouple control recommendations.
    • Note: Consult IHS for additional thermocouple types.

    ANSI Code Conductor Characteristics Temperature Ranged
    Positive Negative °F °C
    J Iron (Magnetic) Constantan (Non-Magnetic) 0 to 1400 -17 to 760
    K Chrome (Non-Magnetic)_ Alumel (Magnetic) 0 to 2300 -17 to 1260


    Power Variations

    Type DW: Distributed Wattage

               /Tempco/Data-Assets/02-Cartridge-Images/WebC072.jpg

    Cartridge heaters can be designed to vary the wattage along the length of the heater. Specify number of zones and the required watts and length per zone starting from the disk end. Leads can be connected externally or internally. Picture shows a heater with Type N externally connected leads. Heaters with other terminations may require a longer cold section at the lead end.

    • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
    • See reference page 2-59 for additional Power Variation Specifications and Information.
    • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

     

    Type GJ: Grounded Element Winding

     

    For DC applications where the electrical circuit is negative grounded, the cartridge heater can be designed with one side of the element winding grounded to the sheath and a single lead wire exiting the cartridge heater.

    • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
    • See reference page 2-59 for additional Power Variation Specifications and Information.
    • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

    Type GL: Ground Lead/Sheath

     

    For those applications requiring a separate ground lead attached to the cartridge heater sheath. Standard ground lead wire is a 10" long insulated stranded conductor. Optional insulated and color coded leads are available.

    • See reference page 2-10 for additional Specifications and Standard (Non-Stock) Ordering Information. 
    • See reference page 2-59 for additional Power Variation Specifications and Information.
    • To reference Standard (Stock & Non-Stock) Order Listings - Select US Measures or Metric Measures.

    Additional Options

    Type TM: Thermistor

    Tempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice.

    • See reference page 2-58 for Thermocouple Specifications.
    • See reference page 2-60 for additional Internal Sensor and Control Information.

    Type RD: RTD Temperature Sensor

    Tempco has the ability to custom design cartridge heaters with built-in temperature sensors such as thermistors and RTDs. For specific applications that have a limited or single set point range, thermistors or RTDs in conjunction with simple electronic controllers can be an economical choice.

    • For thermocouples see reference page 2-58.
    • See reference page 2-60 for additional Internal Sensor and Control Information.

      Standard Electrical Tests & Optional Test Reports

      Standard Electrical Tests and Optional Test Reports

      1. Resistance test — measures ohms at room temperature.

      2. IR (insulation resistance) test — measures the insulation resistance to the flow of current. Standard test is done at 500VDC.

      3. Hipot (high potential) test — a high voltage is applied between a product's current carrying conductors and its metallic enclosure to verify that the insulation is sufficient to protect the operator from electrical shock.

      4. Leakage current test — measures the current that flows from any conductive part to ground.

      5. Heaters can be serialized and test reports can be sent with each shipment if required. Contact IHS with your requirements (844) 862-7880.

       

      Die Penetrant Test

      This non-destructive testing can detect imperfections in weld joints. For critical applications, each individual heater’s weld joints by end cap and fittings can be tested. Certified test reports will be sent with each shipment. Consult IHS for details (844) 862-7880. 

       

      Hydrostatic Pressure Test

      Cartridge heaters with attached pipe fittings can be pressure tested to your specifications. Our testing capabilities can ensure that your products meet your exact specifications. Contact IHS with your requirements (844) 862-7880. 

       

      Typical Applications

      • Plastic Extruders
      • Hot Runner Molds
      • Hot Stamping
      • Medical Equipment
      • Packaging Equipment
      • Molds
      • Aerospace
      • Sealing Bags
      • Semiconductor
      • Plastic Molding
      • Shoe Machinery
      • Food Processing
      • Heating Gases and Liquids
      • Glue Guns
      • Laminating Presses
      • Platens
      • Scientific Equipment
      • Food Service Equipment

      Sku: HDC19100
      Vendor: Tempco
      Call for Product Support & Pricing
      Maximum quantity available reached.

      Related products