{"id":7475982893275,"title":"Tempco Chemical Bath Immersion Tank Heaters","handle":"tempco-chemical-bath-over-the-side-immersion-heaters","description":"\u003cp\u003eTempco Over-The-Side Chemical Bath Immersion Heaters offer a wide variety of sheath material and heater configurations to cover the widest possible spectrum of chemical heating applications.  From plain steel to PTFE covered, Tempco is sure to have the correct heater for even the most difficult solution.\u003c\/p\u003e\n\u003cp\u003eBuilt-in thermal overload protections prevents premature heater burnout in low liquid level conditions.  This thermal protection also guards against a potentially hazardous situation should the heater be in close proximity to combustibles, such a a plastic tank or the medium being heated.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eChemical Bath Immersion Heaters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eDesign Features\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element Coil Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  \u003c\/span\u003eReplaces more expensive alumina or graphite heaters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths are available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e for material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-90 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e for Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e for the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Tempco Teflon (PTFE) Single Element Immersion Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Immersion_Heater_Order_List_-_US_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Single Element Immersion Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Immersion_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH690.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH690.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable height=\"160\" width=\"393\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 394.531px;\"\u003e \u003cimg height=\"176\" width=\"393\" alt=\"Single-Element Coil Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1545.jpg?Large\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1545.jpg?Large\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cimg height=\"243\" width=\"243\" alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element L-Shaped Coil Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available;.  Consult for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-91 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Tempco Teflon (PTFE) Single Element L-Shaped Coil Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Coil_Heater_Order_List_-_US_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Single Element L-Shaped Coil Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Coil_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH691.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH691.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cimg height=\"177\" width=\"393\" alt=\"Single-Element L-Shaped Coil Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1548.jpg?Large\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1548.jpg?Large\"\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" alt=\"Heater Guards\" width=\"243\" height=\"243\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element Round Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-92 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Round_Heater_Order_List_-_US_Measures.pdf?v=1641574028\" title=\"Tempco Teflon (PTFE) Single Element Round Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Round_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Single Element Round Heater Order List - Metric Measures\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH685.jpg\" width=\"263\" height=\"263\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH685.jpg\"\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Single-Element Round Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1546.jpg?Large\" width=\"392\" height=\"175\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element L-Shaped Round Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-93 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Round_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20%20\" title=\"Tempco Teflon (PTFE) Single Element L-Shaped Round Heater Order List - US Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Round_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Single Element L-Shaped Round Heater Order List - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebHXFL.jpg\" width=\"254\" height=\"254\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebHXFL.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1547.jpg\" width=\"394\" height=\"294\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 3-Element L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-94 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_L-Shaped_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Three Element L-Shaped Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_L-Shaped_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Three Element L-Shaped Heater Order List - Metric Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH680.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH680.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Three-Element L-shaped Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1526.jpg?Large\" width=\"393\" height=\"236\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 3-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-95 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Temco Teflon (PTFE) Three Element OTS Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Three Element OTS Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_OTS_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3HXcat.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3HXcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Three-Element OTS Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1525.jpg?Large\" width=\"393\" height=\"177\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 6-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-96 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Six_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574028\" title=\"Tempco Teflon (PTFE) Six Element OTS Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Tubular_Flanged_OEM_Immersion_Heater_Order_List_-_Metric_Measures.pdf?v=1640093077%20\" title=\"Tempco Teflon (PTFE) Six Element OTS Heater Order List - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH684.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH684.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Six-Element OTS Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1531.jpg?Large\" width=\"393\" height=\"177\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 9-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-97 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Nine_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574029\" title=\"Tempco Teflon (PTFE) Nine Element OTS Heater Order List - US Measures Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Nine Element OTS Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Nine_Element_OTS_Heater_Order_List_-_Metric_Measures.pdf?v=1641574029\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"252\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web9HXcat.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web9HXcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg height=\"177\" width=\"393\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1532.jpg?Large\" alt=\"Nine-Element OTS Heater Drawing\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" alt=\"Heater Guards\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Single-Tube Style Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor plating tanks, rinse tanks and other acidic aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM1\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-98 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH681.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH681.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eChoose TMM1 Options\u003cspan\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e4. Watts\u003c\/em\u003e \u003cem\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Triple-Tube Style Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, phosphatizing and concentrated aqueous solutions.\u003c\/span\u003e  \u003cspan data-mce-fragment=\"1\"\u003eCheck the Tempco \u003c\/span\u003eChemical Compatibility Guide\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eand with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDesign Features for TMM2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 962-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-99 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3motsCAT.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3motsCAT.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM2 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Single-Tube L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.   Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM3\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-100 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg height=\"252\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH683.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH683.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM3 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Triple-Tube L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.\u003c\/span\u003e   \u003cspan data-mce-fragment=\"1\"\u003eCheck the Tempco \u003c\/span\u003eChemical Compatibility Guide\u003cspan data-mce-fragment=\"1\"\u003e and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM4\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-101 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3Lcat.jpg\" width=\"253\" height=\"252\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3Lcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM4 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTriple-Tube Vertical Stack L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM5\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-102 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH682.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH682.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM5 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eQuartz 1- and 3-Tube Style Heaters\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eStandard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for KMH\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal\u003c\/em\u003e\u003cbr\u003e\u003cem\u003emounting bracket\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed—other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-103 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH027.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH027.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose KMH Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2022-01-04T09:44:56-05:00","created_at":"2021-12-10T15:28:42-05:00","vendor":"Tempco","type":"","tags":["Electronics","Food \u0026 Beverage","Heaters","Manufacturing","Medical \u0026 Pharmaceutical Production","Plastic Fabrication","Process Heat","Replacement Parts","Tempco"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42171360248027,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"TMT02001","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Tempco Chemical Bath Immersion Tank Heaters","public_title":null,"options":["Default Title"],"price":0,"weight":2268,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters.png?v=1640787424","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-1.png?v=1641407669","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-6.png?v=1641407667","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-7.png?v=1641407668","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-8.png?v=1641407669","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-9.png?v=1641407668","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-10.png?v=1641407671","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-11.png?v=1641407669","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-12.png?v=1641407670","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-13.png?v=1641407668","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-14.png?v=1641407670","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-15.png?v=1641407667","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-16.png?v=1641407667","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-17.png?v=1641407667","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-18.png?v=1641407667","\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-19.png?v=1641407668"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters.png?v=1640787424","options":["Title"],"media":[{"alt":null,"id":28923552202971,"position":1,"preview_image":{"aspect_ratio":2.042,"height":331,"width":676,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters.png?v=1640787424"},"aspect_ratio":2.042,"height":331,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters.png?v=1640787424","width":676},{"alt":null,"id":28957004693723,"position":2,"preview_image":{"aspect_ratio":0.838,"height":828,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-1.png?v=1641407669"},"aspect_ratio":0.838,"height":828,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-1.png?v=1641407669","width":694},{"alt":null,"id":28957004857563,"position":3,"preview_image":{"aspect_ratio":0.938,"height":868,"width":814,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-6.png?v=1641407667"},"aspect_ratio":0.938,"height":868,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-6.png?v=1641407667","width":814},{"alt":null,"id":28957004890331,"position":4,"preview_image":{"aspect_ratio":0.937,"height":869,"width":814,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-7.png?v=1641407668"},"aspect_ratio":0.937,"height":869,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-7.png?v=1641407668","width":814},{"alt":null,"id":28957004923099,"position":5,"preview_image":{"aspect_ratio":0.847,"height":960,"width":813,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-8.png?v=1641407669"},"aspect_ratio":0.847,"height":960,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-8.png?v=1641407669","width":813},{"alt":null,"id":28957004955867,"position":6,"preview_image":{"aspect_ratio":0.846,"height":961,"width":813,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-9.png?v=1641407668"},"aspect_ratio":0.846,"height":961,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-9.png?v=1641407668","width":813},{"alt":null,"id":28957004988635,"position":7,"preview_image":{"aspect_ratio":0.84,"height":967,"width":812,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-10.png?v=1641407671"},"aspect_ratio":0.84,"height":967,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-10.png?v=1641407671","width":812},{"alt":null,"id":28957005021403,"position":8,"preview_image":{"aspect_ratio":0.847,"height":961,"width":814,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-11.png?v=1641407669"},"aspect_ratio":0.847,"height":961,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-11.png?v=1641407669","width":814},{"alt":null,"id":28957005054171,"position":9,"preview_image":{"aspect_ratio":0.848,"height":901,"width":764,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-12.png?v=1641407670"},"aspect_ratio":0.848,"height":901,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-12.png?v=1641407670","width":764},{"alt":null,"id":28957005086939,"position":10,"preview_image":{"aspect_ratio":0.84,"height":909,"width":764,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-13.png?v=1641407668"},"aspect_ratio":0.84,"height":909,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-13.png?v=1641407668","width":764},{"alt":null,"id":28957005119707,"position":11,"preview_image":{"aspect_ratio":0.843,"height":908,"width":765,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-14.png?v=1641407670"},"aspect_ratio":0.843,"height":908,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-14.png?v=1641407670","width":765},{"alt":null,"id":28957005152475,"position":12,"preview_image":{"aspect_ratio":0.842,"height":910,"width":766,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-15.png?v=1641407667"},"aspect_ratio":0.842,"height":910,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-15.png?v=1641407667","width":766},{"alt":null,"id":28957005185243,"position":13,"preview_image":{"aspect_ratio":0.837,"height":830,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-16.png?v=1641407667"},"aspect_ratio":0.837,"height":830,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-16.png?v=1641407667","width":695},{"alt":null,"id":28957005218011,"position":14,"preview_image":{"aspect_ratio":0.835,"height":832,"width":695,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-17.png?v=1641407667"},"aspect_ratio":0.835,"height":832,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-17.png?v=1641407667","width":695},{"alt":null,"id":28957005250779,"position":15,"preview_image":{"aspect_ratio":0.84,"height":826,"width":694,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-18.png?v=1641407667"},"aspect_ratio":0.84,"height":826,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-18.png?v=1641407667","width":694},{"alt":null,"id":28957005283547,"position":16,"preview_image":{"aspect_ratio":0.841,"height":828,"width":696,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-19.png?v=1641407668"},"aspect_ratio":0.841,"height":828,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/TempcoChemicalBathImmersionHeaters-19.png?v=1641407668","width":696}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eTempco Over-The-Side Chemical Bath Immersion Heaters offer a wide variety of sheath material and heater configurations to cover the widest possible spectrum of chemical heating applications.  From plain steel to PTFE covered, Tempco is sure to have the correct heater for even the most difficult solution.\u003c\/p\u003e\n\u003cp\u003eBuilt-in thermal overload protections prevents premature heater burnout in low liquid level conditions.  This thermal protection also guards against a potentially hazardous situation should the heater be in close proximity to combustibles, such a a plastic tank or the medium being heated.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eChemical Bath Immersion Heaters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eDesign Features\u003c\/em\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element Coil Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  \u003c\/span\u003eReplaces more expensive alumina or graphite heaters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths are available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e for material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-90 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e for Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e for the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Tempco Teflon (PTFE) Single Element Immersion Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Immersion_Heater_Order_List_-_US_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Single Element Immersion Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Immersion_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH690.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH690.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable height=\"160\" width=\"393\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 394.531px;\"\u003e \u003cimg height=\"176\" width=\"393\" alt=\"Single-Element Coil Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1545.jpg?Large\" data-mce-fragment=\"1\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1545.jpg?Large\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cimg height=\"243\" width=\"243\" alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element L-Shaped Coil Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available;.  Consult for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-91 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Tempco Teflon (PTFE) Single Element L-Shaped Coil Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Coil_Heater_Order_List_-_US_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Single Element L-Shaped Coil Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Coil_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH691.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH691.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cimg height=\"177\" width=\"393\" alt=\"Single-Element L-Shaped Coil Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1548.jpg?Large\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1548.jpg?Large\"\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" alt=\"Heater Guards\" width=\"243\" height=\"243\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element Round Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-92 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Round_Heater_Order_List_-_US_Measures.pdf?v=1641574028\" title=\"Tempco Teflon (PTFE) Single Element Round Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_Round_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Single Element Round Heater Order List - Metric Measures\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH685.jpg\" width=\"263\" height=\"263\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH685.jpg\"\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Single-Element Round Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1546.jpg?Large\" width=\"392\" height=\"175\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 1-Element L-Shaped Round Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-93 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Round_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20%20\" title=\"Tempco Teflon (PTFE) Single Element L-Shaped Round Heater Order List - US Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Single_Element_L-Shaped_Round_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Single Element L-Shaped Round Heater Order List - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebHXFL.jpg\" width=\"254\" height=\"254\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebHXFL.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1547.jpg\" width=\"394\" height=\"294\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 3-Element L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-94 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_L-Shaped_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Three Element L-Shaped Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_L-Shaped_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\" title=\"Tempco Teflon (PTFE) Three Element L-Shaped Heater Order List - Metric Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH680.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH680.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Three-Element L-shaped Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1526.jpg?Large\" width=\"393\" height=\"236\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 3-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-95 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca title=\"Temco Teflon (PTFE) Three Element OTS Heater Order List - US Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574028%20\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Three Element OTS Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Three_Element_OTS_Heater_Order_List_-_Metric_Measures.pdf?v=1641574028%20\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3HXcat.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3HXcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Three-Element OTS Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1525.jpg?Large\" width=\"393\" height=\"177\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 6-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-96 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Six_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574028\" title=\"Tempco Teflon (PTFE) Six Element OTS Heater Order List - US Measures \u0026amp; Values\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/span\u003e\u003c\/a\u003e or\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Tubular_Flanged_OEM_Immersion_Heater_Order_List_-_Metric_Measures.pdf?v=1640093077%20\" title=\"Tempco Teflon (PTFE) Six Element OTS Heater Order List - Metric Measures \u0026amp; Values\" style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/a\u003e\u003c\/span\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH684.jpg\" width=\"253\" height=\"253\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH684.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg alt=\"Six-Element OTS Heater Drawing\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1531.jpg?Large\" width=\"393\" height=\"177\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg alt=\"Heater Guards\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" width=\"253\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eFluoropolymer (PTFE) 9-Element OTS Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded internal metal element for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee reference page 11-97 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" data-mce-fragment=\"1\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-fragment=\"1\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" data-mce-fragment=\"1\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eTo reference Standard (Stock \u0026amp; Non-Stock) Order Listings - Select \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Nine_Element_OTS_Heater_Order_List_-_US_Measures.pdf?v=1641574029\" title=\"Tempco Teflon (PTFE) Nine Element OTS Heater Order List - US Measures Values\" style=\"color: #ff2a00;\"\u003eUS Measures\u003c\/a\u003e\u003c\/span\u003e or\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Tempco Teflon (PTFE) Nine Element OTS Heater Order List - Metric Measures \u0026amp; Values\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Teflon_PTFE_Nine_Element_OTS_Heater_Order_List_-_Metric_Measures.pdf?v=1641574029\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eMetric Measures\u003c\/span\u003e\u003c\/a\u003e.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"252\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web9HXcat.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web9HXcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cimg height=\"177\" width=\"393\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH1-1532.jpg?Large\" alt=\"Nine-Element OTS Heater Drawing\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH060.jpg?Medium\" alt=\"Heater Guards\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Single-Tube Style Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor plating tanks, rinse tanks and other acidic aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM1\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-98 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH681.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH681.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eChoose TMM1 Options\u003cspan\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e4. Watts\u003c\/em\u003e \u003cem\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Triple-Tube Style Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, phosphatizing and concentrated aqueous solutions.\u003c\/span\u003e  \u003cspan data-mce-fragment=\"1\"\u003eCheck the Tempco \u003c\/span\u003eChemical Compatibility Guide\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eand with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDesign Features for TMM2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal mounting flange\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 962-7880\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-99 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3motsCAT.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3motsCAT.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM2 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Single-Tube L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.   Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM3\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Chemical Compatibility Chart\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-100 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cimg height=\"252\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH683.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH683.jpg\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM3 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eMetal Triple-Tube L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.\u003c\/span\u003e   \u003cspan data-mce-fragment=\"1\"\u003eCheck the Tempco \u003c\/span\u003eChemical Compatibility Guide\u003cspan data-mce-fragment=\"1\"\u003e and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM4\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-101 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3Lcat.jpg\" width=\"253\" height=\"252\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/Web3Lcat.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM4 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eTriple-Tube Vertical Stack L-Shaped Heater\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor plating tanks, rinse tanks and other non-sludging aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for TMM5\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eVapor-tight polypropylene terminal enclosure\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e240, 480 volts standard as listed — other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-102 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH682.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH682.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose TMM5 Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eQuartz 1- and 3-Tube Style Heaters\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eStandard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e\u003cstrong\u003eDesign Features for KMH\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003eT1 thermal fuse protection standard; T2 bi-metal switch optional\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eGrounded for safety\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eVapor-tight polypropylene terminal enclosure with universal\u003c\/em\u003e\u003cbr\u003e\u003cem\u003emounting bracket\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eStandard 3-ft. flexible PVC liquid-tight conduit\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e120, 240, 480 volts standard as listed—other voltages available\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eLonger lengths available.  Consult IHS for additional information (844) 862-7880.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem data-mce-fragment=\"1\"\u003eSee the \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Chemical_Compatibility_Chart.pdf?v=1641925566%20\" title=\"Tempco Chemical Compatibility Chart\" style=\"color: #ff2a00;\"\u003eChemical Compatibility Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor material usage within your application.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee reference page 11-103 for additional Specifications and Ordering Information.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the Immersion Heater \u003cspan style=\"color: #ff2a00;\"\u003e\u003ca title=\"Tempco Electric Immersion Heater Installation \u0026amp; Operating Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Electric_Immersion_Heater_Installation_and_Operating_Instructions.pdf?v=1641918919%20\" style=\"color: #ff2a00;\"\u003eQuick Reference Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor Installation and Operating Instructions.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eSee the\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0249\/4467\/2845\/files\/Application_Guide_for_Thermal_Over-Temp_Devices.pdf?v=1641925566%20\" title=\"Tempco Application Guide for Thermal Over-Temperature Device Features \u0026amp; Specifications\" style=\"color: #ff2a00;\"\u003eApplication Guide\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor the Thermal Over-Temperature Device features and specifications.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/b\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003cimg height=\"253\" width=\"253\" src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH027.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.tempco.com\/Tempco\/Data-Assets\/11-Process-Images\/WebH027.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eChoose KMH Options\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003e(Select for Quote)\u003c\/em\u003e\n\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eLonger lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1. Length: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e2. Hot Zone (Inches): __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e4. Watts\u003c\/em\u003e \u003cem data-mce-fragment=\"1\"\u003e÷ 100: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e7. Thermal Over-Temperature Protection: __________ \u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1L=Solutions up to 180°F Thermal Fuse\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1M=Solutions from 180°F\u003cspan data-mce-fragment=\"1\"\u003e  to 220°F Thermal Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e1H=Solutions from 220°F\u003cspan data-mce-fragment=\"1\"\u003e  to 300°F Thermal Fuse\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2L=Solutions up to 180°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2M=Solutions for 180°F  to 220°F Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2H=Solutions from 220°F  to 300°F  Bi-Metal Switch\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e8. Conduit Length (Inches) __________  (Note: 36\" is standard length)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e9. Quantity: __________\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e"}

Tempco Chemical Bath Immersion Tank Heaters

Product Description

Tempco Over-The-Side Chemical Bath Immersion Heaters offer a wide variety of sheath material and heater configurations to cover the widest possible spectrum of chemical heating applications.  From plain steel to PTFE covered, Tempco is sure to have the correct heater for even the most difficult solution.

Built-in thermal overload protections prevents premature heater burnout in low liquid level conditions.  This thermal protection also guards against a potentially hazardous situation should the heater be in close proximity to combustibles, such a a plastic tank or the medium being heated.

Chemical Bath Immersion Heaters

Design Features

Fluoropolymer (PTFE) 1-Element Coil Heater

Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

  • T1 thermal fuse protection standard; T2 bi-metal switch optional
  • Grounded internal metal element for safety
  • Vapor-tight polypropylene terminal enclosure with universal mounting flange
  • Standard 3-ft. flexible PVC liquid-tight conduit
  • 120, 240, 480 volts standard as listed — other voltages available
  • Longer and shorter vertical lengths are available.  Consult IHS for additional information (844) 862-7880.
  • See reference page 11-90 for additional Specifications and Ordering Information.
  • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
 
 Single-Element Coil Heater Drawing

 Heater Guards

Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  


Fluoropolymer (PTFE) 1-Element L-Shaped Coil Heater

Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

  • T1 thermal fuse protection standard; T2 bi-metal switch optional
  • Grounded internal metal element for safety
  • Vapor-tight polypropylene terminal enclosure with universal mounting flange
  • Standard 3-ft. flexible PVC liquid-tight conduit
  • 120, 240, 480 volts standard as listed — other voltages available
  • Longer and shorter vertical lengths available;.  Consult for additional information (844) 862-7880.
  • See reference page 11-91 for additional Specifications and Ordering Information.
  • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
     

    Single-Element L-Shaped Coil Heater Drawing

     Heater Guards

    Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  

    Fluoropolymer (PTFE) 1-Element Round Heater

    Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

    • T1 thermal fuse protection standard; T2 bi-metal switch optional
    • Grounded internal metal element for safety
    • Vapor-tight polypropylene terminal enclosure with universal mounting flange
    • Standard 3-ft. flexible PVC liquid-tight conduit
    • 120, 240, 480 volts standard as listed — other voltages available
    • Longer and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880
    • See reference page 11-92 for additional Specifications and Ordering Information.
    • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

         

        Single-Element Round Heater Drawing

        Heater Guards

        Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  

        Fluoropolymer (PTFE) 1-Element L-Shaped Round Heater

        Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

        • T1 thermal fuse protection standard; T2 bi-metal switch optional
        • Grounded internal metal element for safety
        • Vapor-tight polypropylene terminal enclosure with universal mounting flange
        • Standard 3-ft. flexible PVC liquid-tight conduit
        • 120, 240, 480 volts standard as listed — other voltages available
        • Longer and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880
        • See reference page 11-93 for additional Specifications and Ordering Information.
        • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
             

            Heater Guards

            Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).

            Fluoropolymer (PTFE) 3-Element L-Shaped Heater

            Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

            • T1 thermal fuse protection standard; T2 bi-metal switch optional
            • Grounded internal metal element for safety
            • Vapor-tight polypropylene terminal enclosure with universal mounting flange
            • Standard 3-ft. flexible PVC liquid-tight conduit
            • 240, 480 volts standard as listed — other voltages available
            • Longer and shorter vertical lengths available.  Consult IHS for additional information
            • See reference page 11-94 for additional Specifications and Ordering Information.
            • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
                 
                Three-Element L-shaped Heater Drawing

                Heater Guards

                Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).

                Fluoropolymer (PTFE) 3-Element OTS Heater

                Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

                • T1 thermal fuse protection standard; T2 bi-metal switch optional
                • Grounded internal metal element for safety
                • Vapor-tight polypropylene terminal enclosure with universal mounting flange
                • Standard 3-ft. flexible PVC liquid-tight conduit
                • 120, 240, 480 volts standard as listed — other voltages available
                • Longer lengths available.  Consult IHS for additional information (844) 862-7880
                • See reference page 11-95 for additional Specifications and Ordering Information.
                • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
                     
                    Three-Element OTS Heater Drawing

                    Heater Guards

                    Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  

                    Fluoropolymer (PTFE) 6-Element OTS Heater

                    Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

                    • T1 thermal fuse protection standard; T2 bi-metal switch optional
                    • Grounded internal metal element for safety
                    • Vapor-tight polypropylene terminal enclosure with universal mounting flange
                    • Standard 3-ft. flexible PVC liquid-tight conduit
                    • 120, 240, 480 volts standard as listed — other voltages available
                    • Longer lengths available.  Consult IHS for additional information
                    • See reference page 11-96 for additional Specifications and Ordering Information.
                    • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
                       
                      Six-Element OTS Heater Drawing

                      Heater Guards

                      Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).

                      Fluoropolymer (PTFE) 9-Element OTS Heater

                      Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.  Replaces more expensive alumina or graphite heaters.

                      • T1 thermal fuse protection standard; T2 bi-metal switch optional
                      • Grounded internal metal element for safety
                      • Vapor-tight polypropylene terminal enclosure with universal mounting flange
                      • Standard 3-ft. flexible PVC liquid-tight conduit
                      • 240, 480 volts standard as listed — other voltages available
                      • Longer lengths available.  Consult IHS for additional information (844) 862-7880
                      • See reference page 11-97 for additional Specifications and Ordering Information.
                      • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
                         
                        Nine-Element OTS Heater Drawing

                        Heater Guards

                        Note: Guards are recommended for all fluoropolymer heaters. Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).

                        Metal Single-Tube Style Heater

                        For plating tanks, rinse tanks and other acidic aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                        Design Features for TMM1

                        • T1 thermal fuse protection standard; T2 bi-metal switch optional
                        • Grounded for safety
                        • Vapor-tight polypropylene terminal enclosure with universal mounting flange
                        • Standard 3-ft. flexible PVC liquid-tight conduit
                        • 120, 240, 480 volts standard as listed — other voltages available
                        • See reference page 11-98 for additional Specifications and Ordering Information.
                        • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

                           

                           

                          Choose TMM1 Options (Select for Quote)

                          Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                          1. Length: __________ 

                          2. Hot Zone (Inches): __________ 

                          3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                          4. Watts ÷ 100: __________

                          5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                          6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                          7. Thermal Over-Temperature Protection: __________ 

                          • 1L=Solutions up to 180°F Thermal Fuse
                          • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                          • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                          • 2L=Solutions up to 180°F  Bi-Metal Switch
                          • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                          • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                          8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                          9. Quantity: __________

                          Metal Triple-Tube Style Heater

                          For plating tanks, phosphatizing and concentrated aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                          Design Features for TMM2

                          • T1 thermal fuse protection standard; T2 bi-metal switch optional
                          • Grounded for safety
                          • Vapor-tight polypropylene terminal enclosure with universal mounting flange
                          • Standard 3-ft. flexible PVC liquid-tight conduit
                          • 120, 240, 480 volts standard as listed — other voltages available
                          • Longer lengths available.  Consult IHS for additional information (844) 962-7880
                          • See reference page 11-99 for additional Specifications and Ordering Information.
                          • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

                             

                            Choose TMM2 Options (Select for Quote)

                            Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                            1. Length: __________ 

                            2. Hot Zone (Inches): __________ 

                            3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                            4. Watts ÷ 100: __________

                            5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                            6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                            7. Thermal Over-Temperature Protection: __________ 

                            • 1L=Solutions up to 180°F Thermal Fuse
                            • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                            • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                            • 2L=Solutions up to 180°F  Bi-Metal Switch
                            • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                            • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                            8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                            9. Quantity: __________

                            Metal Single-Tube L-Shaped Heater

                            For plating tanks, rinse tanks and other non-sludging aqueous solutions.   Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                            Design Features for TMM3

                            • T1 thermal fuse protection standard; T2 bi-metal switch optional
                            • Grounded for safety
                            • Vapor-tight polypropylene terminal enclosure
                            • Standard 3-ft. flexible PVC liquid-tight conduit
                            • 120, 240, 480 volts standard as listed — other voltages available
                            • Longer and shorter vertical lengths available.  Consult IHS for additional information.
                            • See reference page 11-100 for additional Specifications and Ordering Information.
                            • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

                               

                               

                              Choose TMM3 Options (Select for Quote)

                              Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                              1. Length: __________ 

                              2. Hot Zone (Inches): __________ 

                              3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                              4. Watts ÷ 100: __________

                              5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                              6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                              7. Thermal Over-Temperature Protection: __________ 

                              • 1L=Solutions up to 180°F Thermal Fuse
                              • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                              • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                              • 2L=Solutions up to 180°F  Bi-Metal Switch
                              • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                              • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                              8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                              9. Quantity: __________

                              Metal Triple-Tube L-Shaped Heater

                              For plating tanks, rinse tanks and other non-sludging aqueous solutions.   Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                              Design Features for TMM4

                              • T1 thermal fuse protection standard; T2 bi-metal switch optional
                              • Grounded for safety
                              • Vapor-tight polypropylene terminal enclosure
                              • Standard 3-ft. flexible PVC liquid-tight conduit
                              • 240, 480 volts standard as listed — other voltages available
                              • Longer and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.
                              • See reference page 11-101 for additional Specifications and Ordering Information.
                              • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

                                 

                                Choose TMM4 Options (Select for Quote)

                                Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                                1. Length: __________ 

                                2. Hot Zone (Inches): __________ 

                                3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                                4. Watts ÷ 100: __________

                                5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                                6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                                7. Thermal Over-Temperature Protection: __________ 

                                • 1L=Solutions up to 180°F Thermal Fuse
                                • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                                • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                                • 2L=Solutions up to 180°F  Bi-Metal Switch
                                • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                                • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                                8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                                9. Quantity: __________

                                 

                                Triple-Tube Vertical Stack L-Shaped Heater

                                For plating tanks, rinse tanks and other non-sludging aqueous solutions.  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                                Design Features for TMM5

                                • T1 thermal fuse protection standard; T2 bi-metal switch optional
                                • Grounded for safety
                                • Vapor-tight polypropylene terminal enclosure
                                • Standard 3-ft. flexible PVC liquid-tight conduit
                                • 240, 480 volts standard as listed — other voltages available
                                • Longer and shorter vertical lengths available.  Consult IHS for additional information (844) 862-7880.
                                • See reference page 11-102 for additional Specifications and Ordering Information.
                                • See the Application Guide for the Thermal Over-Temperature Device features and specifications.
                                   

                                  Choose TMM5 Options (Select for Quote)

                                  Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                                  1. Length: __________ 

                                  2. Hot Zone (Inches): __________ 

                                  3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                                  4. Watts ÷ 100: __________

                                  5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                                  6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                                  7. Thermal Over-Temperature Protection: __________ 

                                  • 1L=Solutions up to 180°F Thermal Fuse
                                  • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                                  • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                                  • 2L=Solutions up to 180°F  Bi-Metal Switch
                                  • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                                  • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                                  8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                                  9. Quantity: __________

                                  Quartz 1- and 3-Tube Style Heaters

                                  Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180°F (82°C).  Check the Tempco Chemical Compatibility Guide and with chemical supplier for proper sheath material selection.

                                  Design Features for KMH

                                  • T1 thermal fuse protection standard; T2 bi-metal switch optional
                                  • Grounded for safety
                                  • Vapor-tight polypropylene terminal enclosure with universal
                                    mounting bracket
                                  • Standard 3-ft. flexible PVC liquid-tight conduit
                                  • 120, 240, 480 volts standard as listed—other voltages available
                                  • Longer lengths available.  Consult IHS for additional information (844) 862-7880.
                                  • See reference page 11-103 for additional Specifications and Ordering Information.
                                  • See the Application Guide for the Thermal Over-Temperature Device features and specifications.

                                     

                                    Choose KMH Options (Select for Quote)

                                    Longer lengths are available.  Please select your features and specifications, and then contact IHS for a quotation (844) 862-7880.

                                    1. Length: __________ 

                                    2. Hot Zone (Inches): __________ 

                                    3. Material: __________ (A = Steel, B = 304SS, C = 316SS, D = Titanium)

                                    4. Watts ÷ 100: __________

                                    5. Voltage: __________ (1 = 120, 2 = 240, 3 = 480)

                                    6. Phase: __________ (1 = 1 Phase, 3 = 3 Phase)

                                    7. Thermal Over-Temperature Protection: __________ 

                                    • 1L=Solutions up to 180°F Thermal Fuse
                                    • 1M=Solutions from 180°F  to 220°F Thermal Fuse
                                    • 1H=Solutions from 220°F  to 300°F Thermal Fuse
                                    • 2L=Solutions up to 180°F  Bi-Metal Switch
                                    • 2M=Solutions for 180°F  to 220°F Bi-Metal Switch
                                    • 2H=Solutions from 220°F  to 300°F  Bi-Metal Switch

                                    8. Conduit Length (Inches) __________  (Note: 36" is standard length)

                                    9. Quantity: __________

                                    Sku: TMT02001
                                    Vendor: Tempco
                                    Call for Product Support & Pricing
                                    Maximum quantity available reached.

                                    Related products