{"id":4306000150605,"title":"HCS 1\/4 DIN Temperature Controllers","handle":"products-heaters-controls-and-sensors-14-din-temperature-controllers","description":"\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; line-height: 22px;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers can easily be configured to provide precise control. Thanks to its advanced Smarter Logic, \"Fuzzy\" allows processes to be controlled better than ever before, with virtually no initial overshoot or temperature variations. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.25em;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAs the control detects a process disturbance, the fuzzy logic continuous decision making function quickly returns the process value to the setpoint. The large dual displays allow the set point and process value to be visible at all times. In addition, self-diagnostic capabilities, sensor linearization and cold junction compensation are all performed by the powerful, single chip microprocessor. The 2-in. in-panel depth is the shortest of any similar function control available.\u003c\/span\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAutomatic tuning of PID parameters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSelectable input, heating and\/or cooling outputs, degrees C or F\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e2 optional alarms, large displays 5\/8-in. and 1\/2-in.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSealed mylar front panel, external lockout\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAll control parameters adjustable from front panel\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAutomatic\/manual mode operation 2-in. in-panel depth\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers Specifications:\u003c\/h2\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINPUT \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eThermocouple\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eType J,K,T,E,B,R,S,N. (selectable)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRTD\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003ePT 100 ohm(DIN or JIS)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eLinear\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e-10-60mV Configurable input other voltage or current\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDisplay \u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eIn temperature or engineering units\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOutputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSingle output with 2 optional independent alarms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHeating and\/or cooling outputs with 2 optional alarms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRelay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSPST relay rated 3A, 240V maximum resistive load\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePulsed Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e32VDC, 20mA maximum ohms\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e4-20mA, 0-20mA maximum load 500 ohms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0-10V minimum load 500K ohms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarms\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e8 selectable modes each alarm \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSPST relay(s) rated 2A, 240V maximum resistive load\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCONTROL FEATURES \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eTemp Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eSelectable Set Point:\u003cbr\u003e-1999ºF - 3182ºF (-1128ºC - 1750ºC)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarm Set Point\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eFull Range Adjustable\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Modes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eControls can be configured as On\/Off Proportional(P)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional with manual reset Proportional\/Integral(PI)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional Derivative(PD)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional\/Integral\/Derivative(PID) Heating and Cooling\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional Band:O-100% of span\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eIntegral (Reset) \u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e0-3600 seconds\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDerivative (Rate)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0-1000 seconds\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAnti-Reset Wind-Up\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eInhibits integral action outside of proportional band\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eAdjustable deadband from -10 to + 10% of cooling proportional band\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eManual Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eConfigurable as open loop control should sensor no longer function\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCycle Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0 - 120 seconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSensor Break Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eConfigurable status of control and alarms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Action\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSelectable-Direct action for cooling\u003cbr\u003eReverse action for heating\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINDICATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e4 digit red 5\/8-in. LED Process Value Display. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eGreen 1.2-in. LED Set Value display \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSelectable decimal placement for normal or high resolution display\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eExample\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 0000, 000.0, 00.00, 0.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eF \/ C\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eSelectable with 2 LED indicators\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eSample Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250 milliseconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e90-26OVAC, 50\/60Hz C;consumption: less than 5VA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eData Retention\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e10 years (EEPROM)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Stability\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e+\/- 0.15% of full scale\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e-0.25% of range: + -1 c or 0.5C in high resolution\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0.1% ambient\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eExternal Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e100 ohms maximum\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 1\u003cspan\u003e20dB\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e60dB\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003e10M ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 1\u003cspan\u003e4ºF - 122°F (-10ºC-50°C)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e0-90% RH (non-condensing)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e20M ohm minimum (5OOVDC)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eBreakdown\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e2OOVAC,5O\/60Hz 1 minute\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1\u003cspan\u003e0-55Hz amplitude 1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eShock\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e200m\/c(20g)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2019-10-24T10:45:58-04:00","created_at":"2019-10-24T10:45:59-04:00","vendor":"IHS | Industrial Heat Sources","type":"HCS 1\/4 DIN Temperature Controllers","tags":["Controllers\/Sensors","HCS","Process Heat"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30986914365517,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HCS-1\/4DIN-TC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"HCS 1\/4 DIN Temperature Controllers","public_title":null,"options":["Default Title"],"price":0,"weight":227,"compare_at_price":null,"inventory_management":null,"barcode":"HCS-1\/4DIN-TC","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/ihshotair.com\/cdn\/shop\/products\/14dinheat.jpg?v=1572456366"],"featured_image":"\/\/ihshotair.com\/cdn\/shop\/products\/14dinheat.jpg?v=1572456366","options":["Title"],"media":[{"alt":"HCS 1\/4 DIN Temperature Controllers ","id":5533306454093,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/ihshotair.com\/cdn\/shop\/products\/14dinheat.jpg?v=1572456366"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/ihshotair.com\/cdn\/shop\/products\/14dinheat.jpg?v=1572456366","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan style=\"font-family: Verdana; font-size: small; line-height: 22px;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers can easily be configured to provide precise control. Thanks to its advanced Smarter Logic, \"Fuzzy\" allows processes to be controlled better than ever before, with virtually no initial overshoot or temperature variations. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.25em;\"\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAs the control detects a process disturbance, the fuzzy logic continuous decision making function quickly returns the process value to the setpoint. The large dual displays allow the set point and process value to be visible at all times. In addition, self-diagnostic capabilities, sensor linearization and cold junction compensation are all performed by the powerful, single chip microprocessor. The 2-in. in-panel depth is the shortest of any similar function control available.\u003c\/span\u003e \u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAutomatic tuning of PID parameters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSelectable input, heating and\/or cooling outputs, degrees C or F\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003e2 optional alarms, large displays 5\/8-in. and 1\/2-in.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eSealed mylar front panel, external lockout\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAll control parameters adjustable from front panel\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Verdana; font-size: small;\"\u003eAutomatic\/manual mode operation 2-in. in-panel depth\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: left;\"\u003eFuzyPro 1\/4 DIN Temperature Controller Heat\/Cool Controllers Specifications:\u003c\/h2\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINPUT \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eThermocouple\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eType J,K,T,E,B,R,S,N. (selectable)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRTD\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003ePT 100 ohm(DIN or JIS)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eLinear\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e-10-60mV Configurable input other voltage or current\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eDisplay \u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eIn temperature or engineering units\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOutputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSingle output with 2 optional independent alarms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHeating and\/or cooling outputs with 2 optional alarms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eRelay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSPST relay rated 3A, 240V maximum resistive load\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePulsed Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e32VDC, 20mA maximum ohms\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e4-20mA, 0-20mA maximum load 500 ohms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0-10V minimum load 500K ohms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarms\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e8 selectable modes each alarm \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSPST relay(s) rated 2A, 240V maximum resistive load\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCONTROL FEATURES \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eTemp Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eSelectable Set Point:\u003cbr\u003e-1999ºF - 3182ºF (-1128ºC - 1750ºC)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAlarm Set Point\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eFull Range Adjustable\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Modes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eControls can be configured as On\/Off Proportional(P)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional with manual reset Proportional\/Integral(PI)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional Derivative(PD)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional\/Integral\/Derivative(PID) Heating and Cooling\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProportional Band:O-100% of span\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eIntegral (Reset) \u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e0-3600 seconds\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDerivative (Rate)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0-1000 seconds\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAnti-Reset Wind-Up\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eInhibits integral action outside of proportional band\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eAdjustable deadband from -10 to + 10% of cooling proportional band\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eManual Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eConfigurable as open loop control should sensor no longer function\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCycle Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e0 - 120 seconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eSensor Break Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eConfigurable status of control and alarms\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Action\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003eSelectable-Direct action for cooling\u003cbr\u003eReverse action for heating\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"cell-padding: 3px; border: 1px solid grey; width: 75%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; background-image: url('http:\/\/files.www.ihshotair.com\/Table_background.jpg'); padding: 3px;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eINDICATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e4 digit red 5\/8-in. LED Process Value Display. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eGreen 1.2-in. LED Set Value display \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSelectable decimal placement for normal or high resolution display\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eExample\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 0000, 000.0, 00.00, 0.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eF \/ C\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003eSelectable with 2 LED indicators\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30%; border: 1px solid grey; padding: 3px;\"\u003eSample Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e250 milliseconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e90-26OVAC, 50\/60Hz C;consumption: less than 5VA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eData Retention\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e10 years (EEPROM)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eControl Stability\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e+\/- 0.15% of full scale\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e-0.25% of range: + -1 c or 0.5C in high resolution\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e0.1% ambient\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eExternal Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e100 ohms maximum\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 1\u003cspan\u003e20dB\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e60dB\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\u003cspan\u003e10M ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e 1\u003cspan\u003e4ºF - 122°F (-10ºC-50°C)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e0-90% RH (non-condensing)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e20M ohm minimum (5OOVDC)\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eBreakdown\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e\n\u003cspan\u003e2OOVAC,5O\/60Hz 1 minute\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e1\u003cspan\u003e0-55Hz amplitude 1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px;\"\u003eShock\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid grey; padding: 3px; text-align: center;\"\u003e \u003cspan\u003e200m\/c(20g)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HCS 1/4 DIN Temperature Controllers

Product Description

FuzyPro 1/4 DIN Temperature Controller Heat/Cool Controllers can easily be configured to provide precise control. Thanks to its advanced Smarter Logic, "Fuzzy" allows processes to be controlled better than ever before, with virtually no initial overshoot or temperature variations. 

As the control detects a process disturbance, the fuzzy logic continuous decision making function quickly returns the process value to the setpoint. The large dual displays allow the set point and process value to be visible at all times. In addition, self-diagnostic capabilities, sensor linearization and cold junction compensation are all performed by the powerful, single chip microprocessor. The 2-in. in-panel depth is the shortest of any similar function control available. 

FuzyPro 1/4 DIN Temperature Controller Heat/Cool Controllers Features:

  • Automatic tuning of PID parameters
  • Selectable input, heating and/or cooling outputs, degrees C or F 
  • 2 optional alarms, large displays 5/8-in. and 1/2-in.
  • Sealed mylar front panel, external lockout 
  • All control parameters adjustable from front panel 
  • Automatic/manual mode operation 2-in. in-panel depth

FuzyPro 1/4 DIN Temperature Controller Heat/Cool Controllers Specifications:

INPUT 
Thermocouple Type J,K,T,E,B,R,S,N. (selectable) 
RTD PT 100 ohm(DIN or JIS) 
Linear -10-60mV Configurable input other voltage or current 
Display  In temperature or engineering units 
Outputs Single output with 2 optional independent alarms
Heating and/or cooling outputs with 2 optional alarms 
Relay SPST relay rated 3A, 240V maximum resistive load 
Pulsed Voltage  32VDC, 20mA maximum ohms
Current 4-20mA, 0-20mA maximum load 500 ohms 
Voltage 0-10V minimum load 500K ohms 
Alarms 8 selectable modes each alarm 
SPST relay(s) rated 2A, 240V maximum resistive load 
CONTROL FEATURES 
Temp Range  Selectable Set Point:
-1999ºF - 3182ºF (-1128ºC - 1750ºC)
Alarm Set Point  Full Range Adjustable
Control Modes Controls can be configured as On/Off Proportional(P)
Proportional with manual reset Proportional/Integral(PI)
Proportional Derivative(PD)
Proportional/Integral/Derivative(PID) Heating and Cooling
Proportional Band:O-100% of span 
Integral (Reset)   0-3600 seconds
Derivative (Rate) 0-1000 seconds 
Anti-Reset Wind-Up Inhibits integral action outside of proportional band 
Cooling Adjustable deadband from -10 to + 10% of cooling proportional band 
Manual Mode  Configurable as open loop control should sensor no longer function
Cycle Time 0 - 120 seconds 
Sensor Break Protection Configurable status of control and alarms 
Control Action Selectable-Direct action for cooling
Reverse action for heating
 
INDICATION
Display  4 digit red 5/8-in. LED Process Value Display. 
Green 1.2-in. LED Set Value display 
Selectable decimal placement for normal or high resolution display
Example  0000, 000.0, 00.00, 0.000
F / C  Selectable with 2 LED indicators
Sample Rate 250 milliseconds 
Power Supply  90-26OVAC, 50/60Hz C;consumption: less than 5VA
Data Retention 10 years (EEPROM) 
Control Stability +/- 0.15% of full scale 
Accuracy -0.25% of range: + -1 c or 0.5C in high resolution 
Cold Junction Compensation 0.1% ambient 
External Resistance 100 ohms maximum 
Common Mode Rejection  120dB
Normal Mode Rejection  60dB
Input Impedance 10M ohms
Operating Temperature  14ºF - 122°F (-10ºC-50°C)
Humidity  0-90% RH (non-condensing)
Insulation 20M ohm minimum (5OOVDC) 
Breakdown 2OOVAC,5O/60Hz 1 minute 
Vibration 10-55Hz amplitude 1 mm
Shock  200m/c(20g)

 

Sku: HCS-1/4DIN-TC
Call for Product Support & Pricing
Maximum quantity available reached.